Cited by 130Neuroscience and Neural EngineeringVagus Nerve Stimulation ResearchNeurological disorders and treatments

A characterization of the effects on neuronal excitability due to prolonged microstimulation with chronically implanted microelectrodes

McCreery, D.B., Yuen, T.G.H., Agnew, W.F., Bullara, L.A.·1997·IEEE Transactions on Biomedical Engineering

Abstract

Localized, long-lasting stimulation-induced depression of neuronal excitability (SIDNE) is a consequence of prolonged, high-frequency microstimulation in the central nervous system (CNS). It represents a persisting refractory state in the neurons and axons near the stimulating microelectrode, that occurs in the absence of histologically detectable tissue injury. It does not involve a change in synaptic efficacy and, in this respect, it differs from the more familiar phenomenon of long-term depression (LTD). Although SIDNE is ultimately reversible (after several days), it must be taken into account in the design of neural prostheses based on microstimulation in the central nervous system and in animal studies that require prolonged microstimulation in the CNS. In this study, we have characterized the phenomenon, using as the paradigm, iridium microelectrodes implanted chronically in the cat's posteroventral cochlear nucleus. Although the SIDNE may persist for several days after the end of the stimulation protocol, it does not become more severe from day to day when the stimulation protocol is repeated on successive days. The severity of the SIDNE is strongly dependent upon both the instantaneous frequency and the duty cycle of the electrical stimulation. The character of the SIDNE, including its localization to the immediate vicinity of the stimulating microelectrodes, suggests that the phenomenon is a direct consequence of the prolonged electrical excitation of the neurons close to the microelectrode. The problem of designing microstimulation systems that allow high-frequency stimulation of a neural substrate, while minimizing SIDNE are discussed.

Integrity signals

Registry

Crossref · 10.1109/10.634645

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • McCreery et al. suggested the use of a parameter called 'average frequency', equal to stimulus frequency times the percentage of effective stimulation time, as a means of predicting SIDNE, which is considered an early stage of neural damage.

    “McCreery et al. suggested the use of a parameter they called ‘average frequency’, equal to stimulus frequency times the percentage of effective stimulation time, as a means of predicting SIDNE, which is considered an early stage of neural damage [94].”
  • When stimulating the cochlear nucleus in cats for 7 h at higher overall average frequencies above 100 Hz, McCreery et al. noted an increase in the threshold of the evoked response proportional to the average frequency, indicating this parameter is more meaningful than either frequency or percentage of effective stimulation time alone.

    “When stimulating the cochlear nucleus in cats for 7 h at higher overall average frequencies above 100 Hz, they noted an increase in the threshold of the evoked response proportional to the average frequency, indicating this parameter is more meaningful than either frequency or percentage of effective stimulation time alone.”
  • In stimulation of the cochlear nucleus of guinea pigs, McCreery et al. showed that frequencies up to 100 Hz caused no damage nor SIDNE after 7 h of continuous stimulation while higher frequencies of 250 and 500 Hz were damaging.

    “In stimulation of the cochlear nucleus of guinea pigs, McCreery et al. showed that frequencies up to 100 Hz caused no damage nor stimulation-induced depression of neuronal excitability (SIDNE) after 7 h of continuous stimulation while higher frequencies of 250 and 500 Hz were damaging [94].”
  • McCreery et al. showed a correlation between the level of SIDNE and the pulse frequency and stimulation duration, respectively, but no injury could be detected on histological evaluation.

    “They showed a correlation between the level of SIDNE and the pulse frequency and stimulation duration, respectively, but no injury could be detected on histological evaluation [94].”
  • A large part of the literature and of our knowledge about neural stimulation is based on animal studies mostly conducted in the 1980s and 1990s.

    “Consequently, a large part of the literature and of our knowledge about neural stimulation is based on animal studies mostly conducted in the 1980s and 1990s [43–45, 62–64, 75, 92, 94, 96, 99, 100].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
McCreery, D. B., Yuen, T. G. H., Agnew, W. F., & Bullara, L. A.
Affiliations
Huntington Medical Research Institutes (US)
Venue
IEEE Transactions on Biomedical Engineering
Published
1997
Volume
44
Issue
10
Pages
931-939
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2135479849
Cited by
130
References
11
Citations by year
2026: 7 · 2025: 1 · 2024: 3 · 2023: 3 · 2022: 8 · 2021: 4 · 2020: 6 · 2019: 3 · 2018: 6 · 2017: 4 · 2016: 6 · 2015: 3 · 2014: 4 · 2013: 5 · 2012: 5
FWCI
0.66
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Institutes of Health (n01dc002400-000)
  • National Institute on Deafness and Other Communication Disorders (N01-DC-5-2105, N01-DC2400)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
  • Health Sciences › Medicine › Neurology › Neurological disorders and treatments
Keywords
high-frequency electrical stimulation, chronic electrode implantation, posteroventral cochlear nucleus, duty cycle, stimulation frequency, neural prostheses, long-term depression
MeSH terms
Animals, Cats, Cochlear Implants, Electrodes, Implanted, Equipment Design, Evaluation Studies as Topic, Iridium, Microelectrodes, Neurons, Time Factors, Cochlear Nucleus

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review