Spatio-temporal EEG source localization using a three-dimensional subspace FINE approach in a realistic geometry inhomogeneous head model
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
The subspace source localization approach, i.e., first principle vectors (FINE), is able to enhance the spatial resolvability and localization accuracy for closely-spaced neural sources from EEG and MEG measurements. Computer simulations were conducted to evaluate the performance of the FINE algorithm in an inhomogeneous realistic geometry head model under a variety of conditions. The source localization abilities of FINE were examined at different cortical regions and at different depths. The present computer simulation results indicate that FINE has enhanced source localization capability, as compared with MUSIC and RAP-MUSIC, when sources are closely spaced, highly noise-contaminated, or inter-correlated. The source localization accuracy of FINE is better, for closely-spaced sources, than MUSIC at various noise levels, i.e., signal-to-noise ratio (SNR) from 6 dB to 16 dB, and RAP-MUSIC at relatively low noise levels, i.e., 6 dB to 12 dB. The FINE approach has been further applied to localize brain sources of motor potentials, obtained during the finger tapping tasks in a human subject. The experimental results suggest that the detailed neural activity distribution could be revealed by FINE. The present study suggests that FINE provides enhanced performance in localizing multiple closely spaced, and inter-correlated sources under low SNR, and may become an important alternative to brain source localization from EEG or MEG.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pascual-Marqui, R. D., Michel, C. M., & Lehmann, D. (1994) · International Journal of Psychophysiology · doi:10.1016/0167-8760(84)90014-x · Cited by 2,869 · cited 2×
“Typical priors are smoothness [18]–[20], [25] or assumption”
BackgroundCorrelated neuronal activity and the flow of neural information
Salinas, E., & Sejnowski, T. J. (2001) · Nature Reviews Neuroscience · doi:10.1038/35086012 · Cited by 1,333 · cited 1×
“Furthermore, several discussions and efforts from R-MUSIC [28] to RAP-MUSIC [16] in literatures have been made to address the source correlation, which is originated from the observation of the synchronization phenomenon in the brain electrical activity [37–39].”
Multiple dipole modeling and localization from spatio-temporal MEG data
Mosher, J. C., Lewis, P. S., & Leahy, R. M. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141192 · Cited by 1,048
Realistic conductivity geometry model of the human head for interpretation of neuromagnetic data
Hamalainen, M. S., & Sarvas, J. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.16463 · Cited by 989 · cited 1×
“shell realistic geometry inhomogeneous head model [34] was used.”
MethodNeuromagnetic source imaging with FOCUSS: a recursive weighted minimum norm algorithm
Gorodnitsky, I. F., George, J. S., & Rao, B. D. (1995) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(95)00107-a · Cited by 567
Source localization using recursively applied and projected (RAP) MUSIC
Mosher, J. C., & Leahy, R. M. (1999) · IEEE Transactions on Signal Processing · doi:10.1109/78.740118 · Cited by 398 · cited 3×
“Furthermore, several discussions and efforts from R-MUSIC [28] to RAP-MUSIC [16] in literatures have been made to address the source correlation, which is originated from the observation of the synchronization phenomenon in the brain electrical activity [37]–[39].”
BackgroundMethodElectric Dipole Tracing in the Brain by Means of the Boundary Element Method and Its Accuracy
He, B., Musha, T., Okamoto, Y., Homma, S., Nakajima, Y., & Sato, T. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.326056 · Cited by 334 · cited 1×
“Both equivalent current dipole models [9–17] and distributed current source models [18–26] have been extensively investigated and have each proven useful in both EEG and MEG.”
BackgroundSelf-citationAn alternative subspace approach to EEG dipole source localization
Xu, X.-L., Xu, B., & He, B. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/2/010 · Cited by 73 · cited 3×
“(FINE) for 3-D subspace source localization [29], and initially”
BackgroundSelf-citationPaired MEG data set source localization using recursively applied and projected (RAP) MUSIC
Ermer, J. J., Mosher, J. C., Huang, M., & Leahy, R. M. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.867959 · Cited by 64
Cited by
Review on solving the inverse problem in EEG source analysis
Grech, R., Cassar, T., Muscat, J., Camilleri, K. P., Fabri, S. G., Zervakis, M., Xanthopoulos, P., Sakkalis, V., & Vanrumste, B. (2008) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-5-25 · Cited by 1,193
Ictal source analysis: Localization and imaging of causal interactions in humans
Ding, L., Worrell, G. A., Lagerlund, T. D., & He, B. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.09.042 · Cited by 183
“The pseudo-colors displayed with gray MRI slices show the reciprocal of subspace correlations against the FINE vectors at each scanned point within the solution space.”
MethodInfluentialSelf-citationMultimodal Functional Neuroimaging: Integrating Functional MRI and EEG/MEG
He, B., & Liu, Z. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008233 · Cited by 171
Self-citationLu, Y., Yang, L., Worrell, G. A., & He, B. (2012) · Clinical Neurophysiology · doi:10.1016/j.clinph.2011.11.007 · Cited by 98
Self-citationShenoy Handiru, V., Vinod, A. P., & Guan, C. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa6baf · Cited by 36
Metadata
- Authors
- Ding, L., & He, B.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2006-09
- Volume
- 53
- Issue
- 9
- Pages
- 1732-1739
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2149653664
- Cited by
- 31
- References
- 9
- FWCI
- 1.23
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.