Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 259

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Design of patient-specific gait modifications for knee osteoarthritis rehabilitation

Open access
Fregly, Benjamin J., Reinbolt, Jeffrey A., Rooney, Kelly L., Mitchell, Kim H., Chmielewski, Terese L. · 2007 · IEEE Transactions on Biomedical Engineering

Abstract

Abstract-Gait modification is a nonsurgical approach for reducing the external knee adduction torque in patients with knee osteoarthritis (OA). The magnitude of the first adduction torque peak in particular is strongly associated with knee OA progression. While toeing out has been shown to reduce the second peak, no clinically realistic gait modifications have been identified that effectively reduce both peaks simultaneously. This study predicts novel patient-specific gait modifications that achieve this goal without changing the foot path. The modified gait motion was designed for a single patient with knee OA using dynamic optimization of a patient-specific, full-body gait model. The cost function minimized the knee adduction torque subject to constraints limiting how much the new gait motion could deviate from the patient's normal gait motion. The optimizations predicted a "medial-thrust" gait pattern that reduced the first adduction torque peak between 32% and 54% and the second peak between 34% and 56%. The new motion involved three synergistic kinematic changes: slightly decreased pelvis obliquity, slightly increased leg flexion, and slightly increased pelvis axial rotation. After gait retraining, the patient achieved adduction torque reductions of 39% to 50% in the first peak and 37% to 55% in the second one. These reductions are comparable to those reported after high tibial osteotomy surgery. The associated kinematic changes were consistent with the predictions except for pelvis obliquity, which showed little change. This study demonstrates that it is feasible to design novel patient-specific gait modifications with potential clinical benefit using dynamic optimization of patient-specific, full-body gait models. Further investigation is needed to assess the extent to which similar gait modifications may be effective for other patients with knee OA.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2007.891934

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Cited by

See all 259

Metadata

Authors
Fregly, B. J., Reinbolt, J. A., Rooney, K. L., Mitchell, K. H., & Chmielewski, T. L.
Venue
IEEE Transactions on Biomedical Engineering
Published
2007-09
Volume
54
Issue
9
Pages
1687-1695
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2116531629
Cited by
259
References
19
FWCI
6.17
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Design of patient-specific gait modifications for knee osteoarthritis rehabilitation. https://app.cochat.ai/papers/10.1109/tbme.2007.891934
The paper
Fregly, B. J., Reinbolt, J. A., Rooney, K. L., Mitchell, K. H., & Chmielewski, T. L. (2007). Design of patient-specific gait modifications for knee osteoarthritis rehabilitation. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2007.891934

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.