Single-Trial EEG Source Reconstruction for Brain–Computer Interface
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
A new way to improve the classification rate of an EEG-based brain-computer interface (BCI) could be to reconstruct the brain sources of EEG and to apply BCI methods to these derived sources instead of raw measured electrode potentials. EEG source reconstruction methods are based on electrophysiological information that could improve the discrimination between BCI tasks. In this paper, we present an EEG source reconstruction method for BCI. The results are compared with results from raw electrode potentials to enable direct evaluation of the method. Features are based on frequency power change and Bereitschaft potential. The features are ranked with mutual information before being fed to a proximal support vector machine. The dataset IV of the BCI competition II and data from four subjects serve as test data. Results show that the EEG inverse solution improves the classification rate and can lead to results comparable to the best currently known methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 2×
“ABRAIN–COMPUTER interface (BCI) is “a communication system which enables the brain to send messages to the external world without using traditional pathways as nerve or muscle” [1] (Fig.”
BackgroundAnalysis of Discrete Ill-Posed Problems by Means of the L-Curve
Hansen, P. C. (1992) · SIAM Review · doi:10.1137/1034115 · Cited by 3,903 · cited 1×
“Metric methods are the L-curve [ 33 ], the cross-validation error [34], or based on Bayesian inference [35]–[38].”
MethodPascual-Marqui, R. D., Michel, C. M., & Lehmann, D. (1994) · International Journal of Psychophysiology · doi:10.1016/0167-8760(84)90014-x · Cited by 2,869 · cited 7×
“We tested three priors: identity, a spatial correlation (Laplacian), and a location-based prior.”
BackgroundInfluentialOptimal spatial filtering of single trial EEG during imagined hand movement
Ramoser, H., Muller-Gerking, J., & Pfurtscheller, G. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.895946 · Cited by 2,457 · cited 4×
“Spatial filter methods like common spatial pattern [14], [51]”
BackgroundMethodInfluentialBrain–machine interfaces: past, present and future
Lebedev, M. A., & Nicolelis, M. A. L. (2006) · Trends in Neurosciences · doi:10.1016/j.tins.2006.07.004 · Cited by 1,875 · cited 2×
“Studies on nonhuman subjects have shown excellent results in term of usability (simple training , many degrees of freedom) and accuracy (see Lebedev and Nicolelis [2] for review).”
BackgroundControl of a two-dimensional movement signal by a noninvasive brain-computer interface in humans
Wolpaw, J. R., & McFarland, D. J. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0403504101 · Cited by 1,512
Blankertz, B., Muller, K.-R., Curio, G., Vaughan, T. M., Schalk, G., Wolpaw, J. R., Schlogl, A., Neuper, C., Pfurtscheller, G., Hinterberger, T., et al. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826692 · Cited by 670 · cited 3×
“The first dataset was part of the BCI competition 2003 [24].”
BackgroundMethodInfluentialNunez, P. L., & Silberstein, R. B. (2000) · Brain Topography · doi:10.1023/a:1026683200895 · Cited by 307
Motor imagery classification by means of source analysis for brain–computer interface applications
Qin, L., Ding, L., & He, B. (2004) · Journal of Neural Engineering · doi:10.1088/1741-2560/1/3/002 · Cited by 239
Cited by
A review of classification algorithms for EEG-based brain–computer interfaces: A 10 year update
Lotte, F., Bougrain, L., Cichocki, A., Clerc, M., Congedo, M., Rakotomamonjy, A., & Yger, F. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab2f2 · Cited by 2,239
Introduction to machine learning for brain imaging
Lemm, S., Blankertz, B., Dickhaus, T., & Müller, K.-R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.11.004 · Cited by 630
Brain–Computer Interfaces Using Sensorimotor Rhythms: Current State and Future Perspectives
Yuan, H., & He, B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2312397 · Cited by 492
A Review of Multitaper Spectral Analysis
Babadi, B., & Brown, E. N. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2311996 · Cited by 342
Noninvasive Brain-Computer Interfaces Based on Sensorimotor Rhythms
He, B., Baxter, B., Edelman, B. J., Cline, C. C., & Ye, W. W. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2407272 · Cited by 233
“Common statistical measures, including information theoretic metrics, were used to identify regions of interest (ROIs) on the cortex that contained dipoles which best separated MI tasks [106], [107].”
(2013) · Handbook of Clinical Neurology · doi:10.1016/b978-0-444-52901-5.00006-x · Cited by 212
Lotte, F. (2014) · Guide to Brain-Computer Music Interfacing · doi:10.1007/978-1-4471-6584-2_7 · Cited by 178
Asadzadeh, S., Yousefi Rezaii, T., Beheshti, S., Delpak, A., & Meshgini, S. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2020.108740 · Cited by 174
“Real-time source estimates can be used to improve real-time predictions of subject’s intentions compared to sensor-based predictions in applications involving brainmachine interfaces (BMI) and neurofeedback [2, 6-9].”
BackgroundLin, C.-T., Ko, L.-W., Chang, M.-H., Duann, J.-R., Chen, J.-Y., Su, T.-P., & Jung, T.-P. (2010) · Gerontology · doi:10.1159/000230807 · Cited by 133
Metadata
- Authors
- Noirhomme, Q., Kitney, R. I., & Macq, B.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2008-05
- Volume
- 55
- Issue
- 5
- Pages
- 1592-1601
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2163969766
- Cited by
- 75
- References
- 9
- FWCI
- 2.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.