Volitional Control of a Prosthetic Knee Using Surface Electromyography
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper presents a method for providing volitional control of a powered knee prosthesis during nonweight-bearing activity such as sitting. The method utilizes an impedance framework, such that the joint can be programmed with a given stiffness and damping that reflects the nominal impedance properties of an intact joint. Volitional movement of the knee joint is commanded via the stiffness set-point angle of the joint impedance, which is commanded by the user as a function of the measured surface electromyogram (EMG) from the hamstring and quadriceps muscles of the residual limb. Rather than using the respective EMG measurements from these muscles to directly command the flexion or extension set point of the knee, the presented approach utilizes a combination of quadratic discriminant analysis and principal component analysis to align the user's intent to flex or extend the knee joint with the pattern of measured EMG. The approach was implemented on three transfemoral amputees, and their ability to control knee movement was characterized by a set of knee joint trajectory tracking tasks. Each amputee subject also performed the same set of trajectory tracking tasks with his sound side (intact) knee joint. The average root mean square trajectory tracking errors of the prosthetic knee employing the EMG-based volitional control and the intact knee of the three subjects were 6.2° and 5.2°, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2002) · Springer Series in Statistics · doi:10.1007/b98835 · Cited by 919
Research works printed but not linked: 23
- 10.1007/BF02442284 · doi:10.1007/bf02442284
- 10.1016/0141-5425(90)90037-N · DOI · Paper page
- 10.1016/0141-5425(92)90052-M · doi:10.1016/0141-5425(92)90052-m
- 10.1109/IEMBS.1995.579704 · doi:10.1109/iembs.1995.579704
- 10.1109/TBME.2008.2003293 · DOI · Paper page
- 10.1109/TNSRE.2007.910282 · DOI · Paper page
- donath, 1974, Proportional EMG control for above-knee prostheses
- 10.1109/ICORR.2005.1501123 · DOI · Paper page
- 10.1016/j.neunet.2008.03.006 · DOI · Paper page
- ferris, 2005, an ankle-foot orthosis powered by artificial pneumatic muscles, J Appl Biomech, 21, 189, 10.1123/jab.21.2.189 · DOI · Paper page
- 10.1016/j.apmr.2005.11.026 · DOI
- 10.1682/JRRD.2008.09.0131 · doi:10.1682/jrrd.2008.09.0131
- popovic, 1988, Electrophysiological Kinesiology Intern Congress Ser No 804 Excerpta Medica, 337
- 10.1108/03684920810907869 · doi:10.1108/03684920810907869
- makhsous, 2007, measuring tissue perfusion during pressure relief maneuvers: insights into preventing pressure ulcers, J Spinal Cord Med, 30, 497, 10.1080/10790268.2007.11754584 · doi:10.1080/10790268.2007.11754584
- 10.1115/1.3426293 · DOI · Paper page
- 10.1109/TBME.2009.2034734 · DOI · Paper page
- 10.1109/TMECH.2009.2032688 · DOI · Paper page
- 10.1007/BF02474569 · doi:10.1007/bf02474569
- 10.1016/j.gaitpost.2005.05.004 · DOI · Paper page
- kawamoto, 2002, power assist system hal-3 for gait disorder person, Computer Helping People with Special Needs, 2398, 19
- 10.1186/1743-0003-4-48 · DOI
- mclachlan, 2004, Discriminant Analysis and Statistical Pattern Recognition
Cited by
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
“Surface EMG has been demonstrated for this purpose in transfemoral prostheses [61,120,130,132,149,150], virtual above- and below-knee prostheses [151], a hip and knee orthosis [152], knee orthoses [60,153,154], a transtibial prosthesis [66] and an ankle-foot orthosis [155].”
Toward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
Active lower limb prosthetics: a systematic review of design issues and solutions
Windrich, M., Grimmer, M., Christ, O., Rinderknecht, S., & Beckerle, P. (2016) · BioMedical Engineering OnLine · doi:10.1186/s12938-016-0284-9 · Cited by 272
Qiu, S., Feng, J., Xu, R., Xu, J., Wang, K., He, F., Qi, H., Zhao, X., Zhou, P., Zhang, L., et al. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2407834 · Cited by 39
“At the same time, surface electromyography (EMG), a noninvasive method to measure muscle activities, is extensively used in investigating muscle function and fatigue [11]–[14].”
MethodPapapicco, V., Chen, B., Munih, M., Davalli, A., Sacchetti, R., Gruppioni, E., Crea, S., & Vitiello, N. (2021) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2021.3075096 · Cited by 19
Metadata
- Authors
- Ha, K. H., Varol, H. A., & Goldfarb, M.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2011-01
- Volume
- 58
- Issue
- 1
- Pages
- 144-151
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W1985158854
- Cited by
- 205
- References
- 1
- FWCI
- 7.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.