A Two-Hop Wireless Power Transfer System With an Efficiency-Enhanced Power Receiver for Motion-Free Capsule Endoscopy Inspection
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
This paper presents a wireless power transfer system for a motion-free capsule endoscopy inspection. Conventionally, a wireless power transmitter in a specifically designed jacket has to be connected to a strong power source with a long cable. To avoid the power cable and allow patients to walk freely in a room, this paper proposes a two-hop wireless power transfer system. First, power is transferred from a floor to a power relay in the patient's jacket via strong coupling. Next, power is delivered from the power relay to the capsule via loose coupling. Besides making patients much more conformable, the proposed techniques eliminate the sources of reliability issues arisen from the moving cable and connectors. In the capsule, it is critical to enhance the power conversion efficiency. This paper develops a switch-mode rectifier (rectifying efficiency of 93.6%) and a power combination circuit (enhances combining efficiency by 18%). Thanks to the two-hop transfer mechanism and the novel circuit techniques, this system is able to transfer an average power of 24 mW and a peak power of 90 mW from the floor to a 13 mm × 27 mm capsule over a distance of 1 m with the maximum dc-to-dc power efficiency of 3.04%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A low-power integrated circuit for a wireless 100-electrode neural recording system.
Harrison, R. R., Watkins, P. T., Kier, R. J., Lovejoy, R. O., Black, D. J., Greger, B., & Solzbacher, F. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.886567 · Cited by 782
Design of radio-frequency powered coils for implant instruments
Ko, W. H., Liang, S. P., & Fung, C. D. F. (1977) · Medical & Biological Engineering & Computing · doi:10.1007/bf02457921 · Cited by 374
Lee, S. B., Lee, H.-M., Kiani, M., Jow, U.-M., & Ghovanloo, M. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2078814 · Cited by 220
Research works printed but not linked: 41
- nakamoto, 2006, A passive UHF RFID tag LSI with 36.6% efficiency CMOS-only rectifier and current-mode demodulator in 0.35 um FeRAM technology, Proc Int Conf Solid-State Circuits, 1201
- 10.1109/TBCAS.2010.2072782 · DOI · Paper page
- 10.1109/TCSII.2010.2048403 · DOI · Paper page
- 10.1109/TAP.2010.2044321 · DOI
- 10.1109/APCCAS.2010.5774924 · doi:10.1109/apccas.2010.5774924
- 10.1109/TPEL.2009.2017195 · DOI · Paper page
- 10.1109/TIE.2011.2112317 · DOI · Paper page
- 10.1109/TMAG.2010.2093534 · DOI · Paper page
- 10.1109/TMAG.2010.2087010 · DOI · Paper page
- 10.1109/LAWP.2010.2068534 · doi:10.1109/lawp.2010.2068534
- 10.1109/ASSCC.2011.6123644 · doi:10.1109/asscc.2011.6123644
- 10.1109/JSSC.2004.835822 · DOI · Paper page
- 10.1016/j.proeng.2011.12.247 · doi:10.1016/j.proeng.2011.12.247
- 10.1007/s11517-007-0223-9 · DOI
- sun, 2010, An asymmetric resonant coupling wireless power transmission link for Micro-Ball endoscopy, Proc Int Conf Eng Med Biol Soc, 6531
- 10.1109/ICMA.2011.5985662 · DOI
- 10.1109/TBME.2008.919721 · DOI
- 10.1109/TBCAS.2009.2034364 · DOI
- 10.1109/ISSCC.2010.5434028 · DOI · Paper page
- 10.1109/ISSCC.2009.4977424 · DOI · Paper page
- 10.1109/TIE.2008.2010110 · DOI · Paper page
- 10.1016/j.bios.2009.08.049 · DOI
- 10.1109/TCSII.2009.2032465 · DOI
- 10.1109/TBME.2010.2087332 · DOI
- 10.1016/j.sna.2011.03.036 · DOI
- 10.1109/TIE.2009.2023633 · DOI
- 10.1016/j.bios.2006.06.015 · DOI · Paper page
- 10.1016/j.sna.2009.12.025 · doi:10.1016/j.sna.2009.12.025
- 10.1088/0960-1317/21/5/054008 · DOI
- 10.1109/TBCAS.2008.2006493 · DOI
- 10.1109/ASSCC.2011.6123633 · DOI
- 10.1109/JSSC.2006.882884 · DOI
- yoo, 2009, A 5.2 mW self-configured wearable body sensor network controller and a 12 uW 54.9% efficiency wirelessly powered sensor for continuous health monitoring system, Proc Int Conf Solid-State Circuits, 290
- 10.1109/ISSCC.2010.5433933 · DOI · Paper page
- 10.1109/ISSCC.2010.5433936 · doi:10.1109/isscc.2010.5433936
- finkenzeller, 2003, RFID Handbook Fundamentals and Applications in Contactless Smart Cards and Identification, 10.1002/0470868023 · DOI · Paper page
- terman, 1943, Radio Engineers Handbook
- 10.1109/IEMBS.2007.4352793 · DOI
- ohandely, 2008, Improved wireless transcutaneous power transmission for in vivo applications, IEEE Sensor J, 8, 57, 10.1109/JSEN.2007.912899 · DOI · Paper page
- kurs, 2007, Wireless power transfer via strongly coupled magnetic resonances, Science, 317, 83, 10.1126/science.1143254 · DOI · Paper page
- 1998, ICNIRP Guidelines for limiting exposure to time-varying electric, magnetic and electromagnetic fields (up to 300 GHz), Health Phys, 74, 492
Cited by
Wireless Power Transfer—An Overview
Zhang, Z., Pang, H., Georgiadis, A., & Cecati, C. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2835378 · Cited by 1,723
Wireless power transfer techniques for implantable medical devices: a review
Khan, S. R., Pavuluri, S. K., Cummins, G., & Desmulliez, M. P. Y. (2020) · Sensors · doi:10.3390/s20123487 · Cited by 355
“6% [103], 87% [104] and 86% [105] efficiencies for MIDs.”
MethodOpportunities and Challenges for Near-Field Wireless Power Transfer: A Review
Jawad, A. M., Nordin, R., Gharghan, S. K., Jawad, H. M., & Ismail, M. (2017) · Energies · doi:10.3390/en10071022 · Cited by 268
An Improved Wearable Resonant Wireless Power Transfer System for Biomedical Capsule Endoscope
Basar, M. R., Ahmad, M. Y., Cho, J., & Ibrahim, F. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2801781 · Cited by 208
Frequency Decrease Analysis of Resonant Wireless Power Transfer
Zhang, Y., Zhao, Z., & Chen, K. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2277783 · Cited by 159
“Compared with IWPT, relatively large power can be transferred in RWPT with high efficiency over distances on the order of several times the diameter of the transmission coils, but the driving frequency is often much higher than that in IWPT [2]–[4], usually of the order of several MHz [5]–[15].”
BackgroundModeling of capacitive resonant wireless power and data transfer to deep biomedical implants
Narayanamoorthi, R. (2019) · IEEE Transactions on Components, Packaging and Manufacturing Technology · doi:10.1109/tcpmt.2019.2922046 · Cited by 62
Lyu, H., John, M., Burkland, D., Greet, B., Post, A., Babakhani, A., & Razavi, M. (2020) · Scientific Reports · doi:10.1038/s41598-020-59017-z · Cited by 51
Metadata
- Authors
- Sun, T., Xie, X., Li, G., Gu, Y., Deng, Y., & Wang, Z.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2012-11
- Volume
- 59
- Issue
- 11
- Pages
- 3247-3254
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2036275108
- Cited by
- 148
- References
- 3
- FWCI
- 6.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.