Noncontact Accurate Measurement of Cardiopulmonary Activity Using a Compact Quadrature Doppler Radar Sensor
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
The designed sensor enables accurate reconstruction of chest-wall movement caused by cardiopulmonary activities, and the algorithm enables estimation of respiration, heartbeat rate, and some indicators of heart rate variability (HRV). In particular, quadrature receiver and arctangent demodulation with calibration are introduced for high linearity representation of chest displacement; 24-bit ADCs with oversampling are adopted for radar baseband acquisition to achieve a high signal resolution; continuous-wavelet filter and ensemble empirical mode decomposition (EEMD) based algorithm are applied for cardio/pulmonary signal recovery and separation so that accurate beat-to-beat interval can be acquired in time domain for HRV analysis. In addition, the wireless sensor is realized and integrated on a printed circuit board compactly. The developed sensor system is successfully tested on both simulated target and human subjects. In simulated target experiments, the baseband signal-to-noise ratio (SNR) is 73.27 dB, high enough for heartbeat detection. The demodulated signal has 0.35% mean squared error, indicating high demodulation linearity. In human subject experiments, the relative error of extracted beat-to-beat intervals ranges from 2.53% to 4.83% compared with electrocardiography (ECG) R-R peak intervals. The sensor provides an accurate analysis for heart rate with the accuracy of 100% for p = 2% and higher than 97% for p = 1%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Huang, N. E., Shen, Z., Long, S. R., Wu, M. C., Shih, H. H., Zheng, Q., Yen, N.-C., Tung, C. C., & Liu, H. H. (1998) · Proceedings of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rspa.1998.0193 · Cited by 23,564
ENSEMBLE EMPIRICAL MODE DECOMPOSITION: A NOISE-ASSISTED DATA ANALYSIS METHOD
WU, Z., & HUANG, N. E. (2009) · Advances in Adaptive Data Analysis · doi:10.1142/s1793536909000047 · Cited by 8,715 · cited 1×
“EEMD algorithm is proposed as a noise-assisted data analysis method for solving the EMD-mode mixing and other problems [19].”
Droitcour, A. D., Boric-Lubecke, O., Lubecke, V. M., Lin, J., & Kovacs, G. T. A. (2004) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2004.823552 · Cited by 662 · cited 3×
“Demodulation sensitivity variation with the target’s distance can be solved by using a quadrature receiver and arctangent demodulation since it overcomes target position limitation and small angle limitation [4].”
Arctangent Demodulation With DC Offset Compensation in Quadrature Doppler Radar Receiver Systems
Park, B.-K., Boric-Lubecke, O., & Lubecke, V. M. (2007) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2007.895653 · Cited by 604
Random Body Movement Cancellation in Doppler Radar Vital Sign Detection
Li, C., & Lin, J. (2008) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2008.2007139 · Cited by 448
Chen, K.-M., Huang, Y., Zhang, J., & Norman, A. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.817625 · Cited by 445
An X-Band Microwave Life-Detection System
Chen, K., Misra, D. K., Wang, H., Chuang, H.-R., & Postow, E. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325760 · Cited by 306 · cited 1×
“related theoretical explains have demonstrated that microwave Doppler radar has potential to provide a practical tool for noncontact detecting cardiopulmonary activity [1]–[4].”
Li, C., Xiao, Y., & Lin, J. (2006) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2006.884652 · Cited by 245
Assessment of Heart Rate Variability and Respiratory Sinus Arrhythmia via Doppler Radar
Massagram, W., Lubecke, V. M., Host-Madsen, A., & Boric-Lubecke, O. (2009) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2009.2029716 · Cited by 180
Cited by
Emotion recognition using wireless signals
Zhao, M., Adib, F., & Katabi, D. (2016) · Proceedings of the 22nd Annual International Conference on Mobile Computing and Networking · doi:10.1145/2973750.2973762 · Cited by 461
“In particular, past work that does not require users to hold their breath has an average error of 30-50 milliseconds [13, 40, 27], which is of the same order or larger than the variations in the beat-to-beat intervals themselves, precluding emotion recognition (as we show empirically in §7.”
BackgroundVideo-Based Heart Rate Measurement: Recent Advances and Future Prospects
Chen, X., Cheng, J., Song, R., Liu, Y., Ward, R., & Wang, Z. J. (2019) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2879706 · Cited by 227
“based technique [12], radar-based technique [13], capacitively coupled sensors-based technique [14], and imaging photoplethysmography (iPPG) [11], [15]–[22] technique.”
MethodmmHRV: Contactless Heart Rate Variability Monitoring Using Millimeter-Wave Radio
Wang, F., Zeng, X., Wu, C., Wang, B., & Liu, K. J. R. (2021) · IEEE Internet of Things Journal · doi:10.1109/jiot.2021.3075167 · Cited by 192
“A simple approach based on two Band-Pass Filters (BPFs) is employed for separating the respiration and the heartbeat signal in [26] [27], however, since undesired peaks caused by the interference (e.”
Method
Metadata
- Authors
- Hu, W., Zhao, Z., Wang, Y., Zhang, H., & Lin, F.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2014-03
- Volume
- 61
- Issue
- 3
- Pages
- 725-735
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2090269566
- Cited by
- 247
- References
- 16
- FWCI
- 7.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.