An Implantable Pressure Sensing System With Electromechanical Interrogation Scheme
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
In this paper, we report on the development of an implantable pressure sensing system that is powered by mechanical vibrations in the audible acoustic frequency range. This technique significantly enhances interrogation range, alleviates the misalignment issues commonly encountered with inductive powering, and simplifies the external receiver circuitry. The interrogation scheme consists of two phases: a mechanical vibration phase and an electrical radiation phase. During the first phase, a piezoelectric cantilever acts as an acoustic receiver and charges a capacitor by converting sound vibration harmonics occurring at its resonant frequency into electrical power. In the subsequent electrical phase, when the cantilever is not vibrating, the stored electric charge is discharged across an LC tank whose inductor is pressure sensitive; hence, when the LC tank oscillates at its natural resonant frequency, it radiates a high-frequency signal that is detectable using an external receiver and its frequency corresponds to the measured pressure. The pressure sensitive inductor consists of a planar coil (single loop of wire) with a ferrite core whose distance to the coil varies with applied pressure. A prototype of the implantable pressure sensor is fabricated and tested, both in vitro and in vivo (swine bladder). A pressure sensitivity of 1 kHz/cm H2O is achieved with minimal misalignment sensitivity (26% drop at 90° misalignment between the implanted device and acoustic source; 60% drop at 90° misalignment between the implanted device and RF receiver coil).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Iddan, G., Meron, G., Glukhovsky, A., & Swain, P. (2000) · Nature · doi:10.1038/35013140 · Cited by 3,066
Abraham, W. T., Adamson, P. B., Bourge, R. C., Aaron, M. F., Costanzo, M. R., Stevenson, L. W., Strickland, W., Neelagaru, S., Raval, N., Krueger, S., et al. (2011) · The Lancet · doi:10.1016/s0140-6736(11)60101-3 · Cited by 1,744
An Implantable 64-Channel Wireless Microsystem for Single-Unit Neural Recording
Sodagar, A. M., Perlin, G. E., Yao, Y., Najafi, K., & Wise, K. D. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2023159 · Cited by 218
Cited by
Wireless power transfer techniques for implantable medical devices: a review
Khan, S. R., Pavuluri, S. K., Cummins, G., & Desmulliez, M. P. Y. (2020) · Sensors · doi:10.3390/s20123487 · Cited by 355
LC Passive Wireless Sensors Toward a Wireless Sensing Platform: Status, Prospects, and Challenges
Huang, Q.-A., Dong, L., & Wang, L.-F. (2016) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2016.2602298 · Cited by 284
A review of acoustic power transfer for bio-medical implants
Basaeri, H., Christensen, D. B., & Roundy, S. (2016) · Smart Materials and Structures · doi:10.1088/0964-1726/25/12/123001 · Cited by 202
Chronically implanted pressure sensors: challenges and state of the field
Yu, L., Kim, B., & Meng, E. (2014) · Sensors · doi:10.3390/s141120620 · Cited by 200
Wireless power transfer approaches for medical implants: a review
Haerinia, M., & Shadid, R. (2020) · Signals · doi:10.3390/signals1020012 · Cited by 174
“et o s are restricte t a s rt tra sfer ista ce, isali ent issues ay cc r [94], a t e a etic fiel i te sit ust be under specified limitations for the safety of the body exposure.”
BackgroundInfluential
Metadata
- Authors
- Kim, A., Powell, C. R., & Ziaie, B.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2014-07
- Volume
- 61
- Issue
- 7
- Pages
- 2209-2217
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2018169419
- Cited by
- 59
- References
- 3
- FWCI
- 2.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.