The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Improvements in Remote Cardiopulmonary Measurement Using a Five Band Digital Camera
Open accessAbstract
Remote measurement of the blood volume pulse via photoplethysmography (PPG) using digital cameras and ambient light has great potential for healthcare and affective computing. However, traditional RGB cameras have limited frequency resolution. We present results of PPG measurements from a novel five band camera and show that alternate frequency bands, in particular an orange band, allowed physiological measurements much more highly correlated with an FDA approved contact PPG sensor. In a study with participants (n = 10) at rest and under stress, correlations of over 0.92 (p 0.01) were obtained for heart rate, breathing rate, and heart rate variability measurements. In addition, the remotely measured heart rate variability spectrograms closely matched those from the contact approach. The best results were obtained using a combination of cyan, green, and orange (CGO) bands; incorporating red and blue channel observations did not improve performance. In short, RGB is not optimal for this problem: CGO is better. Incorporating alternative color channel sensors should not increase the cost of such cameras dramatically.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Akselrod, S., Gordon, D., Ubel, F. A., Shannon, D. C., Berger, A. C., & Cohen, R. J. (1981) · Science · doi:10.1126/science.6166045 · Cited by 5,079
Kleiger, R. E., Miller, J. P., Bigger, J. T., & Moss, A. J. (1987) · The American Journal of Cardiology · doi:10.1016/0002-9149(87)90795-8 · Cited by 3,995
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Blind beamforming for non-gaussian signals
Cardoso, J. F., & Souloumiac, A. (1993) · IEE Proceedings F Radar and Signal Processing · doi:10.1049/ip-f-2.1993.0054 · Cited by 2,738
Remote plethysmographic imaging using ambient light
Verkruysse, W., Svaasand, L. O., & Nelson, J. S. (2008) · Optics Express · doi:10.1364/oe.16.021434 · Cited by 1,719
Non-contact, automated cardiac pulse measurements using video imaging and blind source separation
Poh, M.-Z., McDuff, D. J., & Picard, R. W. (2010) · Optics Express · doi:10.1364/oe.18.010762 · Cited by 1,643
Self-citationAdvancements in Noncontact, Multiparameter Physiological Measurements Using a Webcam
Poh, M.-Z., McDuff, D. J., & Picard, R. W. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2086456 · Cited by 1,486
Self-citationEulerian video magnification for revealing subtle changes in the world
Wu, H.-Y., Rubinstein, M., Shih, E., Guttag, J., Durand, F., & Freeman, W. (2012) · ACM Transactions on Graphics · doi:10.1145/2185520.2185561 · Cited by 1,357
An advanced detrending method with application to HRV analysis
Tarvainen, M. P., Ranta-aho, P. O., & Karjalainen, P. A. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.979357 · Cited by 1,131
Important influence of respiration on human R-R interval power spectra is largely ignored
Brown, T. E., Beightol, L. A., Koh, J., & Eckberg, D. L. (1993) · Journal of Applied Physiology · doi:10.1152/jappl.1993.75.5.2310 · Cited by 770
Cited by
DeepPhys: Video-Based Physiological Measurement Using Convolutional Attention Networks
Chen, W., & McDuff, D. (2018) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-01216-8_22 · Cited by 716
Self-citationPhotoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging
Sun, Y., & Thakor, N. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2476337 · Cited by 556
DistancePPG: Robust non-contact vital signs monitoring using a camera
Kumar, M., Veeraraghavan, A., & Sabharwal, A. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.001565 · Cited by 417
RhythmNet: End-to-End Heart Rate Estimation From Face via Spatial-Temporal Representation
Niu, X., Shan, S., Han, H., & Chen, X. (2020) · IEEE Transactions on Image Processing · doi:10.1109/tip.2019.2947204 · Cited by 420
Tulyakov, S., Alameda-Pineda, X., Ricci, E., Yin, L., Cohn, J. F., & Sebe, N. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.263 · Cited by 340
Remote measurement of cognitive stress via heart rate variability
McDuff, D., Gontarek, S., & Picard, R. (2014) · 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2014.6944243 · Cited by 308
Self-citationCOGCAM: Contact-free Measurement of Cognitive Stress During Computer Tasks with a Digital Camera
McDuff, D. J., Hernandez, J., Gontarek, S., & Picard, R. W. (2016) · Proceedings of the 2016 CHI Conference on Human Factors in Computing Systems · doi:10.1145/2858036.2858247 · Cited by 113
Self-citationPhotoplethysmogram-based Cognitive Load Assessment Using Multi-Feature Fusion Model
Zhang, X., Lyu, Y., Qu, T., Qiu, P., Luo, X., Zhang, J., Fan, S., & Shi, Y. (2019) · ACM Transactions on Applied Perception · doi:10.1145/3340962 · Cited by 28
Imaging Photoplethysmography: What are the Best Locations on the Face to Estimate Heart Rate?
Fallet, S., Moser, V., Braun, F., & Vesin, J.-M. (2016) · 2016 Computing in Cardiology Conference (CinC) · doi:10.22489/cinc.2016.098-236 · Cited by 28
Metadata
- Authors
- McDuff, D., Gontarek, S., & Picard, R. W.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2014-10
- Volume
- 61
- Issue
- 10
- Pages
- 2593-2601
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2010270685
- Cited by
- 287
- References
- 25
- FWCI
- 12.58
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.