The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Exploiting Spatial Redundancy of Image Sensor for Motion Robust rPPG
Open accessAbstract
Remote photoplethysmography (rPPG) techniques can measure cardiac activity by detecting pulse-induced color variations on human skin using an RGB camera. State-of-the-art rPPG methods are sensitive to subject body motions (e.g., motion-induced color distortions). This study proposes a novel framework to improve the motion robustness of rPPG. The basic idea of this paper originates from the observation that a camera can simultaneously sample multiple skin regions in parallel, and each of them can be treated as an independent sensor for pulse measurement. The spatial redundancy of an image sensor can thus be exploited to distinguish the pulse signal from motion-induced noise. To this end, the pixel-based rPPG sensors are constructed to estimate a robust pulse signal using motion-compensated pixel-to-pixel pulse extraction, spatial pruning, and temporal filtering. The evaluation of this strategy is not based on a full clinical trial, but on 36 challenging benchmark videos consisting of subjects that differ in gender, skin types, and performed motion categories. Experimental results show that the proposed method improves the SNR of the state-of-the-art rPPG technique from 3.34 to 6.76 dB, and the agreement ( ±1.96σ) with instantaneous reference pulse rate from 55% to 80% correct. ANOVA with post hoc comparison shows that the improvement on motion robustness is significant. The rPPG method developed in this study has a performance that is very close to that of the contact-based sensor under realistic situations, while its computational efficiency allows real-time processing on an off-the-shelf computer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The validity and practicality of sun-reactive skin types I through VI
Fitzpatrick, T. B. (1988) · Archives of Dermatology · doi:10.1001/archderm.1988.01670060015008 · Cited by 4,339
Online Object Tracking: A Benchmark
Wu, Y., Lim, J., & Yang, M.-H. (2013) · 2013 IEEE Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2013.312 · Cited by 4,138
Robust pulse rate from chrominance-based rPPG
de Haan, G., & Jeanne, V. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2266196 · Cited by 1,378
Cited by
Algorithmic principles of remote PPG
Wang, W., den Brinker, A. C., Stuijk, S., & de Haan, G. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2609282 · Cited by 1,234
Self-citationDeepPhys: Video-Based Physiological Measurement Using Convolutional Attention Networks
Chen, W., & McDuff, D. (2018) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-01216-8_22 · Cited by 716
Unsupervised skin tissue segmentation for remote photoplethysmography
Bobbia, S., Macwan, R., Benezeth, Y., Mansouri, A., & Dubois, J. (2019) · Pattern Recognition Letters · doi:10.1016/j.patrec.2017.10.017 · Cited by 615
RhythmNet: End-to-End Heart Rate Estimation From Face via Spatial-Temporal Representation
Niu, X., Shan, S., Han, H., & Chen, X. (2020) · IEEE Transactions on Image Processing · doi:10.1109/tip.2019.2947204 · Cited by 420
Tulyakov, S., Alameda-Pineda, X., Ricci, E., Yin, L., Cohn, J. F., & Sebe, N. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.263 · Cited by 340
Metadata
- Authors
- Wang, W., Stuijk, S., & de Haan, G.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2015-02
- Volume
- 62
- Issue
- 2
- Pages
- 415-425
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2128585298
- Cited by
- 284
- References
- 3
- FWCI
- 9.27
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.