The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
A Novel Algorithm for Remote Photoplethysmography: Spatial Subspace Rotation
Abstract
In this paper, we propose a conceptually novel algorithm, namely "Spatial Subspace Rotation" (2SR), that improves the robustness of remote photoplethysmography. Based on the assumption of 1) spatially redundant pixel-sensors of a camera, and 2) a well-defined skin mask, our core idea is to estimate a spatial subspace of skin-pixels and measure its temporal rotation for pulse extraction, which does not require skin-tone or pulse-related priors in contrast to existing algorithms. The proposed algorithm is thoroughly assessed on a benchmark dataset containing 54 videos, which includes challenges of various skin-tones, body-motions in complex illuminance conditions, and pulse-rate recovery after exercise. The experimental results show that given a well-defined skin mask, 2SR outperforms the popular ICA-based approach and two state-of-the-art algorithms (CHROM and PBV). When comparing the pulse frequency spectrum, 2SR improves on average the SNR of ICA by 2.22 dB, CHROM by 1.56 dB, and PBV by 1.95 dB. When comparing the instant pulse-rate, 2SR improves on average the Pearson correlation and precision of ICA by 47% and 65%, CHROM by 22% and 23%, and PBV by 21% and 39%. ANOVA confirms the significant improvement of 2SR in peak-to-peak accuracy. The proposed 2SR algorithm is very simple to use and extend, i.e., the implementation only requires a few lines MATLAB code.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Remote plethysmographic imaging using ambient light
Verkruysse, W., Svaasand, L. O., & Nelson, J. S. (2008) · Optics Express · doi:10.1364/oe.16.021434 · Cited by 1,719
Advancements in Noncontact, Multiparameter Physiological Measurements Using a Webcam
Poh, M.-Z., McDuff, D. J., & Picard, R. W. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2086456 · Cited by 1,486
Robust pulse rate from chrominance-based rPPG
de Haan, G., & Jeanne, V. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2266196 · Cited by 1,378
Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging
Sun, Y., & Thakor, N. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2476337 · Cited by 556
Improved motion robustness of remote-PPG by using the blood volume pulse signature
de Haan, G., & van Leest, A. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/9/1913 · Cited by 491
Self-citationNon-contact video-based vital sign monitoring using ambient light and auto-regressive models
Tarassenko, L., Villarroel, M., Guazzi, A., Jorge, J., Clifton, D. A., & Pugh, C. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/5/807 · Cited by 423
Measuring pulse rate with a webcam — A non-contact method for evaluating cardiac activity
Lewandowska, M., Rumiński, J., Kocejko, T., & Nowak, J. (2011) · Cited by 420
Francis, J. G. F. (1962) · The Computer Journal · doi:10.1093/comjnl/4.4.332 · Cited by 382
Heart rate measurement based on a time-lapse image.
Takano, C., & Ohta, Y. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.09.006 · Cited by 345
Exploiting Spatial Redundancy of Image Sensor for Motion Robust rPPG
Wang, W., Stuijk, S., & de Haan, G. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2356291 · Cited by 284
Self-citationSun, Y. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3602852 · Cited by 214
A survey of remote optical photoplethysmographic imaging methods
McDuff, D. J., Estepp, J. R., Piasecki, A. M., & Blackford, E. B. (2015) · 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319857 · Cited by 204
Motion-Resistant Remote Imaging Photoplethysmography Based on the Optical Properties of Skin
Feng, L., Po, L.-M., Xu, X., Li, Y., & Ma, R. (2015) · IEEE Transactions on Circuits and Systems for Video Technology · doi:10.1109/tcsvt.2014.2364415 · Cited by 186
Ventricular arrhythmias associated with long-term endurance sports: what is the evidence?
Heidbüchel, H., Prior, D., & Gerche, A. L. (2012) · British Journal of Sports Medicine · doi:10.1136/bjsports-2012-091162 · Cited by 155
Learning-based heart rate detection from remote photoplethysmography features
Hsu, Y., Lin, Y.-L., & Hsu, W. H. (2014) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2014.6854440 · Cited by 71
Unsupervised Subject Detection via Remote PPG
Wang, W., Stuijk, S., & de Haan, G. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2438321 · Cited by 43
Self-citationRemote stress detection using a visible spectrum camera
Kaur, B., Moses, S., Luthra, M., & Ikonomidou, V. N. (2015) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2177159 · Cited by 13
Integrating Remote PPG in Facial Expression Analysis Framework
Tasli, H. E., Gudi, A., & den Uyl, M. J. (2014) · INTERNATIONAL CONFERENCE ON MULTIMODAL INTERACTION · doi:10.1145/2663204.2669626 · Cited by 9
Cited by
Algorithmic principles of remote PPG
Wang, W., den Brinker, A. C., Stuijk, S., & de Haan, G. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2609282 · Cited by 1,234
Self-citationDeepPhys: Video-Based Physiological Measurement Using Convolutional Attention Networks
Chen, W., & McDuff, D. (2018) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-01216-8_22 · Cited by 716
Unsupervised skin tissue segmentation for remote photoplethysmography
Bobbia, S., Macwan, R., Benezeth, Y., Mansouri, A., & Dubois, J. (2019) · Pattern Recognition Letters · doi:10.1016/j.patrec.2017.10.017 · Cited by 615
RhythmNet: End-to-End Heart Rate Estimation From Face via Spatial-Temporal Representation
Niu, X., Shan, S., Han, H., & Chen, X. (2020) · IEEE Transactions on Image Processing · doi:10.1109/tip.2019.2947204 · Cited by 420
Yu, Z., Peng, W., Li, X., Hong, X., & Zhao, G. (2019) · 2019 IEEE/CVF International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2019.00024 · Cited by 340
Metadata
- Authors
- Wang, W., Stuijk, S., & de Haan, G.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2016-09
- Volume
- 63
- Issue
- 9
- Pages
- 1974-1984
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2424269919
- Cited by
- 370
- References
- 18
- FWCI
- 8.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.