The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Motion-compensated noncontact imaging photoplethysmography to monitor cardiorespiratory status during exercise
Open accessAbstract
With the advance of computer and photonics technology, imaging photoplethysmography [(PPG), iPPG] can provide comfortable and comprehensive assessment over a wide range of anatomical locations. However, motion artifact is a major drawback in current iPPG systems, particularly in the context of clinical assessment. To overcome this issue, a new artifact-reduction method consisting of planar motion compensation and blind source separation is introduced in this study. The performance of the iPPG system was evaluated through the measurement of cardiac pulse in the hand from 12 subjects before and after 5 min of cycling exercise. Also, a 12-min continuous recording protocol consisting of repeated exercises was taken from a single volunteer. The physiological parameters (i.e., heart rate, respiration rate), derived from the images captured by the iPPG system, exhibit functional characteristics comparable to conventional contact PPG sensors. Continuous recordings from the iPPG system reveal that heart and respiration rates can be successfully tracked with the artifact reduction method even in high-intensity physical exercise situations. The outcome from this study thereby leads to a new avenue for noncontact sensing of vital signs and remote physiological assessment, with clear applications in triage and sports training.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Reliability and validity of scores on The Emergency Severity Index version 3
Tanabe, P., Gimbel, R., Yarnold, P. R., Kyriacou, D. N., & Adams, J. G. (2004) · Academic Emergency Medicine · doi:10.1197/j.aem.2003.06.013 · Cited by 326
The effect of contacting force on photoplethysmographic signals
Teng, X. F., & Zhang, Y. T. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/5/020 · Cited by 171
Cited by
Robust pulse rate from chrominance-based rPPG
de Haan, G., & Jeanne, V. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2266196 · Cited by 1,378
Unsupervised skin tissue segmentation for remote photoplethysmography
Bobbia, S., Macwan, R., Benezeth, Y., Mansouri, A., & Dubois, J. (2019) · Pattern Recognition Letters · doi:10.1016/j.patrec.2017.10.017 · Cited by 615
Improved motion robustness of remote-PPG by using the blood volume pulse signature
de Haan, G., & van Leest, A. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/9/1913 · Cited by 491
Non-contact video-based vital sign monitoring using ambient light and auto-regressive models
Tarassenko, L., Villarroel, M., Guazzi, A., Jorge, J., Clifton, D. A., & Pugh, C. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/5/807 · Cited by 423
DistancePPG: Robust non-contact vital signs monitoring using a camera
Kumar, M., Veeraraghavan, A., & Sabharwal, A. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.001565 · Cited by 417
Metadata
- Authors
- Sun, Y.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2011-07-01
- Volume
- 16
- Issue
- 7
- Pages
- 077010
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2117320287
- Cited by
- 214
- References
- 4
- FWCI
- 5.11
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Motion-compensated noncontact imaging photoplethysmography to monitor cardiorespiratory status during exercise. https://app.cochat.ai/papers/10.1117/1.3602852
- The paper
- Sun, Y. (2011). Motion-compensated noncontact imaging photoplethysmography to monitor cardiorespiratory status during exercise. Journal of Biomedical Optics. https://doi.org/10.1117/1.3602852
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.