CoChat

Riemannian Geometry Applied to Detection of Respiratory States From EEG Signals: The Basis for a Brain–Ventilator Interface

Open access
Navarro-Sune, X., Hudson, A. L., Fallani, F. De Vico, Martinerie, J., Witon, A., Pouget, P., Raux, M., Similowski, T., Chavez, M. · 2017 · IEEE Transactions on Biomedical Engineering
Cited by 41

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

GOAL: During mechanical ventilation, patient-ventilator disharmony is frequently observed and may result in increased breathing effort, compromising the patient's comfort and recovery. This circumstance requires clinical intervention and becomes challenging when verbal communication is difficult. In this study, we propose a brain-computer interface (BCI) to automatically and noninvasively detect patient-ventilator disharmony from electroencephalographic (EEG) signals: a brain-ventilator interface (BVI). METHODS: Our framework exploits the cortical activation provoked by the inspiratory compensation when the subject and the ventilator are desynchronized. Use of a one-class approach and Riemannian geometry of EEG covariance matrices allows effective classification of respiratory states. The BVI is validated on nine healthy subjects that performed different respiratory tasks that mimic a patient-ventilator disharmony. RESULTS: Classification performances, in terms of areas under receiver operating characteristic curves, are significantly improved using EEG signals compared to detection based on air flow. Reduction in the number of electrodes that can achieve discrimination can be often desirable (e.g., for portable BCI systems). By using an iterative channel selection technique, the common highest order ranking, we find that a reduced set of electrodes (n = 6) can slightly improve for an intrasubject configuration, and it still provides fairly good performances for a general intersubject setting. CONCLUSION: Results support the discriminant capacity of our approach to identify anomalous respiratory states, by learning from a training set containing only normal respiratory epochs. SIGNIFICANCE: The proposed framework opens the door to BVIs for monitoring patient's breathing comfort and adapting ventilator parameters to patient respiratory needs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2016.2592820

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 41

Metadata

Authors
Navarro-Sune, X., Hudson, A. L., Fallani, F. D. V., Martinerie, J., Witon, A., Pouget, P., Raux, M., Similowski, T., & Chavez, M.
Venue
IEEE Transactions on Biomedical Engineering
Published
2017-05
Volume
64
Issue
5
Pages
1138-1148
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2233001524
Cited by
41
References
5
FWCI
2.94
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Riemannian Geometry Applied to Detection of Respiratory States From EEG Signals: The Basis for a Brain–Ventilator Interface. https://app.cochat.ai/papers/10.1109/tbme.2016.2592820
The paper
Navarro-Sune, X., Hudson, A. L., Fallani, F. D. V., Martinerie, J., Witon, A., Pouget, P., Raux, M., Similowski, T., & Chavez, M. (2017). Riemannian Geometry Applied to Detection of Respiratory States From EEG Signals: The Basis for a Brain–Ventilator Interface. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2016.2592820

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.