Position and Orientation Insensitive Wireless Power Transmission for EnerCage-Homecage System
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
We have developed a new headstage architecture as part of a smart experimental arena, known as the EnerCage-HC2 system, which automatically delivers stimulation and collects behavioral data over extended periods with minimal small animal subject handling or personnel intervention in a standard rodent homecage. Equipped with a four-coil inductive link, the EnerCage-HC2 system wirelessly powers the receiver (Rx) headstage, irrespective of the subject's location or head orientation, eliminating the need for tethering or carrying bulky batteries. On the transmitter (Tx) side, a driver coil, five high-quality (Q) factor segmented resonators at different heights and orientations, and a closed-loop Tx power controller create a homogeneous electromagnetic (EM) field within the homecage 3-D space, and compensate for drops in power transfer efficiency (PTE) due to Rx misalignments. The headstage is equipped with four small slanted resonators, each covering a range of head orientations with respect to the Tx resonators, which direct the EM field toward the load coil at the bottom of the headstage. Moreover, data links based on Wi-Fi, UART, and Bluetooth low energy are utilized to enables remote communication and control of the Rx. The PTE varies within 23.6%-33.3% and 6.7%-10.1% at headstage heights of 8 and 20 cm, respectively, while continuously delivering >40 mW to the Rx electronics even at 90° rotation. As a proof of EnerCage-HC2 functionality in vivo, a previously documented on-demand electrical stimulation of the globus pallidus, eliciting consistent head rotation, is demonstrated in three freely behaving rats.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Soft, stretchable, fully implantable miniaturized optoelectronic systems for wireless optogenetics
Park, S. I., Brenner, D. S., Shin, G., Morgan, C. D., Copits, B. A., Chung, H. U., Pullen, M. Y., Noh, K. N., Davidson, S., Oh, S. J., et al. (2015) · Nature Biotechnology · doi:10.1038/nbt.3415 · Cited by 794
Implanted Neural Interfaces: Biochallenges and Engineered Solutions
Grill, W. M., Norman, S. E., & Bellamkonda, R. V. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124927 · Cited by 488 · cited 1×
“A SIGNIFICANT number of preclinical studies designed to better understand normal function of the central nervous system (CNS) and the etiology of neuropathological disorders are conducted in small animal models, mostly rodents, and often require wearable/implantable devices (WIDs) attached to or implanted in the anima…”
The impact of environmental enrichment in laboratory rats—Behavioural and neurochemical aspects
Simpson, J., & Kelly, J. P. (2011) · Behavioural Brain Research · doi:10.1016/j.bbr.2011.04.002 · Cited by 480
Ideal homes? Housing effects on rodent brain and behaviour
Würbel, H. (2001) · Trends in Neurosciences · doi:10.1016/s0166-2236(00)01718-5 · Cited by 471 · cited 2×
“The environment within homecage has the potential to significantly affect brain neurochemistry in rats and the resulting behavior, suggesting its influence on the quality of the collected data [11]–[15].”
A Figure-of-Merit for Designing High-Performance Inductive Power Transmission Links
Kiani, M., & Ghovanloo, M. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2227914 · Cited by 146 · cited 1×
“The diameter and number of turns of the wire-wound L31–L34 and L4 were selected by compromising between the headstage size/weight and coupling coefficient between Tx-Rx resonators and Q-factors of L31–L34 and L4, which ultimately affect the PTE, according to the optimization procedure in [34], at the nominal height of…”
Self-citationEnerCage: A Smart Experimental Arena With Scalable Architecture for Behavioral Experiments
Jow, U.-M., McMenamin, P., Kiani, M., Manns, J. R., & Ghovanloo, M. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2278180 · Cited by 62
Self-citation
Cited by
Wireless power transfer techniques for implantable medical devices: a review
Khan, S. R., Pavuluri, S. K., Cummins, G., & Desmulliez, M. P. Y. (2020) · Sensors · doi:10.3390/s20123487 · Cited by 355
Wireless opto-electro neural interface for experiments with small freely behaving animals
Jia, Y., Khan, W., Lee, B., Fan, B., Madi, F., Weber, A., Li, W., & Ghovanloo, M. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aac810 · Cited by 47
“Currently, we are developing the next generation headstage, which can be inductively powered in the EnerCage-HC2 system [36, 49, 50], to support experiments with unlimited duration on both rats and mice.”
BackgroundMethodSelf-citationAdvances in Neural Recording and Stimulation Integrated Circuits
Li, J., Liu, X., Mao, W., Chen, T., & Yu, H. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.663204 · Cited by 21
Metadata
- Authors
- Jia, Y., Mirbozorgi, S. A., Wang, Z., Hsu, C.-C., Madsen, T. E., Rainnie, D., & Ghovanloo, M.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2017-10
- Volume
- 64
- Issue
- 10
- Pages
- 2439-2449
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2605185300
- Cited by
- 67
- References
- 6
- FWCI
- 3.58
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.