CoChat

Reduction of Blood Glucose Measurements to Calibrate Subcutaneous Glucose Sensors: A Bayesian Multiday Framework

Acciaroli, Giada, Vettoretti, Martina, Facchinetti, Andrea, Sparacino, Giovanni, Cobelli, Claudio · 2018 · IEEE Transactions on Biomedical Engineering
Cited by 36

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: In most continuous glucose monitoring (CGM) devices used for diabetes management, the electrical signal measured by the sensor is transformed to glucose concentration by a calibration function whose parameters are estimated using self-monitoring of blood glucose (SMBG) samples. The calibration function is usually a linear model approximating the nonlinear relationship between electrical signal and glucose concentration in certain time intervals. Thus, CGM devices require frequent calibrations, usually twice a day. The aim here is to develop a new method able to reduce the frequency of calibrations. METHODS: The algorithm is based on a multiple-day model of sensor time-variability with second-order statistical priors on its unknown parameters. In an online setting, these parameters are numerically determined by the Bayesian estimation exploiting SMBG sparsely collected by the patient. The method is assessed retrospectively on 108 CGM signals acquired for 7 days by the Dexcom G4 Platinum sensor, testing progressively less-calibration scenarios. RESULTS: Despite the reduction of calibration frequency (on average from 2/day to 0.25/day), the method shows a statistically significant accuracy improvement compared to manufacturer calibration, e.g., mean absolute relative difference when compared to a laboratory reference decreases from 12.83% to 11.62% (p-value of 0.006). CONCLUSION: The methodology maintains (sometimes improves) CGM sensor accuracy compared to that of the original manufacturer, while reducing the frequency of calibrations. SIGNIFICANCE: Reducing the need of calibrations facilitates the adoption of CGM technology both in terms of ease of use and cost, an obvious prerequisite for its use as replacement of traditional SMBG devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2017.2706974

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 36

Metadata

Authors
Acciaroli, G., Vettoretti, M., Facchinetti, A., Sparacino, G., & Cobelli, C.
Venue
IEEE Transactions on Biomedical Engineering
Published
2018-03
Volume
65
Issue
3
Pages
587-595
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2619079930
Cited by
36
References
7
FWCI
3.71
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reduction of Blood Glucose Measurements to Calibrate Subcutaneous Glucose Sensors: A Bayesian Multiday Framework. https://app.cochat.ai/papers/10.1109/tbme.2017.2706974
The paper
Acciaroli, G., Vettoretti, M., Facchinetti, A., Sparacino, G., & Cobelli, C. (2018). Reduction of Blood Glucose Measurements to Calibrate Subcutaneous Glucose Sensors: A Bayesian Multiday Framework. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2017.2706974

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.