CoChat

Reducing Sensor Noise in MEG and EEG Recordings Using Oversampled Temporal Projection

Larson, Eric, Taulu, Samu · 2018 · IEEE Transactions on Biomedical Engineering
Cited by 58

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: Here, we review the theory of suppression of spatially uncorrelated, sensor-specific noise in electro- and magentoencephalography (EEG and MEG) arrays, and introduce a novel method for suppression. Our method requires only that the signals of interest are spatially oversampled, which is a reasonable assumption for many EEG and MEG systems. METHODS: Our method is based on a leave-one-out procedure using overlapping temporal windows in a mathematical framework to project spatially uncorrelated noise in the temporal domain. RESULTS: This method, termed "oversampled temporal projection" (OTP), has four advantages over existing methods. First, sparse channel-specific artifacts are suppressed while limiting mixing with other channels, whereas existing linear, time-invariant spatial operators can spread such artifacts to other channels with a spatial distribution which can be mistaken for one produced by an electrophysiological source. Second, OTP minimizes distortion of the spatial configuration of the data. During source localization (e.g., dipole fitting), many spatial methods require corresponding modification of the forward model to avoid bias, while OTP does not. Third, noise suppression factors at the sensor level are maintained during source localization, whereas bias compensation removes the denoising benefit for spatial methods that require such compensation. Fourth, OTP uses a time-window duration parameter to control the tradeoff between noise suppression and adaptation to time-varying sensor characteristics. CONCLUSION: OTP efficiently optimizes noise suppression performance while controlling for spatial bias of the signal of interest. SIGNIFICANCE: This is important in applications where sensor noise significantly limits the signal-to-noise ratio, such as high-frequency brain oscillations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2017.2734641

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 24

  1. 10.1007/BF02512476 · DOI · Paper page
  2. kupers, 2017, Broadband spectral responses in visual cortex revealed by a new MEG denoising algorithm, BioRxiv
  3. 10.1016/0141-5425(83)90001-8 · doi:10.1016/0141-5425(83)90001-8
  4. 10.1109/10.668741 · DOI · Paper page
  5. 10.1007/s11517-013-1069-y · DOI
  6. 10.1016/j.jneumeth.2007.09.012 · DOI
  7. 10.1016/j.jneumeth.2016.01.005 · DOI
  8. 10.1109/10.245606 · DOI · Paper page
  9. 10.1088/0031-9155/32/1/004 · DOI · Paper page
  10. 10.1007/BF00681735 · DOI · Paper page
  11. 10.1111/j.1749-6632.1982.tb50789.x · DOI · Paper page
  12. 10.1007/978-3-642-33045-2_2 · DOI
  13. 10.1016/j.clinph.2015.06.008 · DOI
  14. 10.1109/MCSE.2011.37 · DOI · Paper page
  15. 10.1002/9783527609956.ch11 · doi:10.1002/9783527609956.ch11
  16. 10.1016/j.neuroimage.2013.08.070 · DOI · Paper page
  17. 10.1212/01.wnl.0000344402.20334.81 · DOI · Paper page
  18. niedermeyer, 2004, Electroencephalography Basic Principles Clinical Applications and Related Fields
  19. 10.1016/j.neuron.2008.04.020 · DOI
  20. 10.1007/BF02534144 · DOI · Paper page
  21. 10.1016/j.jneumeth.2007.06.003 · DOI · Paper page
  22. 10.3389/fnins.2013.00267 · DOI · Paper page
  23. 10.1063/1.1935742 · DOI · Paper page
  24. 10.1155/2011/879716 · DOI · Paper page

Cited by

See all 58

Metadata

Authors
Larson, E., & Taulu, S.
Venue
IEEE Transactions on Biomedical Engineering
Published
2018-05
Volume
65
Issue
5
Pages
1002-1013
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2739780474
Cited by
58
References
3
FWCI
1.86
Type
journal article
Language
en
Open access
closed
Funders
Washington State Life Sciences Discovery Fund

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.