A Model-Based Image Reconstruction Algorithm With Simultaneous Beam Hardening Correction for X-Ray CT
The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Beam hardening is a well-known effect in X-ray CT scanning that is caused by the interaction of a broad polychromatic source spectrum with energy-dependent material attenuation. If the scanned object only consists of a single material, the beam hardening effect can be corrected by sinogram precorrection techniques. However, when multiple materials are present, it becomes much more difficult to fully compensate for this distortion; in general, the beam hardening can contribute to reconstruction artifacts such as cupping and streaking. In this paper, we present a novel model-based iterative reconstruction algorithm that incorporates beam hardening correction (MBIR-BHC). Unlike most correction algorithms, which require knowledge of the X-ray spectrum or mass attenuation functions, the MBIR-BHC algorithm works by simultaneously reconstructing the image and estimating the beam-hardening function. The method is based on the assumption that the object is formed by a combination of two distinct materials that can be separated based on their densities. We formulate a poly-energetic X-ray forward model using a polynomial function of two material projections: one for the low-density material and one for the high. We then develop an alternating minimization algorithm for jointly estimating the reconstructed image, the material segmentation, and the coefficients of the two component polynomial that models the beam-hardening function. With this approach, the spectrum and mass attenuation functions are not needed in advance, and the correction is adapted to the dataset being reconstructed. We examine the performance of the proposed algorithm using both simulated and real datasets. Results indicate that the MBIR-BHC algorithm significantly reduces several reconstruction artifacts without advanced knowledge of the X-ray spectrum and material properties.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Regression shrinkage and selection via the lasso
Tibshirani, R. (1996) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1996.tb02080.x · Cited by 51,482 · cited 1×
“The solution to (74) can be obtained using the shrinkage operator in solving LASSO and l1 regularized problems [48], and the closed form solution is given by (53).”
Energy-selective reconstructions in X-ray computerised tomography
Alvarez, R. E., & Macovski, A. (1976) · Physics in Medicine & Biology · doi:10.1088/0031-9155/21/5/002 · Cited by 2,013 · cited 1×
“Another approach is dual energy scanning [11], [12].”
BackgroundComputed Tomography: Principles, Design, Artifacts, and Recent Advances
Hsieh, J. (2015) · doi:10.1117/3.2197756 · Cited by 1,400
Tissue Substitutes in Radiation Dosimetry and Measurement
Cloutier, R. J. (1989) · Radiation Research · doi:10.2307/3577533 · Cited by 1,076 · cited 1×
“The densities and the mass attenuation coefficients of the materials used in the phantoms are obtained from the NIST XCOM database [49] and the chemical compositions of these materials are listed in Table VIII according to [50].”
MethodSturgeon, R. (1988) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/0584-8547(88)80189-7 · Cited by 979
A three‐dimensional statistical approach to improved image quality for multislice helical CT
Thibault, J., Sauer, K. D., Bouman, C. A., & Hsieh, J. (2007) · Medical Physics · doi:10.1118/1.2789499 · Cited by 937 · cited 2×
“For the pixel pairwise potential ρ, we use the q-generalized Gaussian MRF (q-GGMRF) potential function [34], given by”
BackgroundMethodSelf-citationBeam hardening in X-ray reconstructive tomography
Brooks, R. A., & Chiro, G. D. (1976) · Physics in Medicine and Biology · doi:10.1088/0031-9155/21/3/004 · Cited by 721 · cited 3×
“One widely-used algorithmic correction is linearization, or polynomial pre-correction [2], [8]–[10].”
BackgroundMethodAn iterative maximum-likelihood polychromatic algorithm for CT
De Man, B., Nuyts, J., Dupont, P., Marchal, G., & Suetens, P. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.959297 · Cited by 430 · cited 2×
“Several methods have also been developed in order to address the problem of beam hardening in the context of iterative reconstruction [22]–[25].”
MethodCatalogue of diagnostic x-ray spectra and other data
Cranley, K. (1997) · Medical Entomology and Zoology · Cited by 418
Realistic CT simulation using the 4D XCAT phantom
Segars, W. P., Mahesh, M., Beck, T. J., Frey, E. C., & Tsui, B. M. W. (2008) · Medical Physics · doi:10.1118/1.2955743 · Cited by 412
Fast Model-Based X-Ray CT Reconstruction Using Spatially Nonhomogeneous ICD Optimization
Yu, Z., Thibault, J.-B., Bouman, C. A., Sauer, K. D., & Hsieh, J. (2011) · IEEE Transactions on Image Processing · doi:10.1109/tip.2010.2058811 · Cited by 290 · cited 2×
“Following the similar strategy in [35], the j-th pixel update can be computed by solving the 1D optimization given by”
MethodSelf-citationA Method for Correcting Bone Induced Artifacts in Computed Tomography Scanners
Joseph, P. M., & Spital, R. D. (1978) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-197801000-00017 · Cited by 281 · cited 1×
“Alternatively, iterative post-processing techniques are lso widely used when the object being scanned is composed of two known materials that can be easily segmented [13]–[17].”
MethodAn iterative approach to the beam hardening correction in cone beam CT
Hsieh, J., Molthen, R. C., Dawson, C. A., & Johnson, R. H. (2000) · Medical Physics · doi:10.1118/1.598853 · Cited by 280 · cited 1×
“Alternatively, iterative post-processing techniques are also widely used when the object being scanned is composed of two known materials that can be easily segmented [13]–[17].”
MethodEmpirical beam hardening correction (EBHC) for CT
Kyriakou, Y., Meyer, E., Prell, D., & Kachelrieß, M. (2010) · Medical Physics · doi:10.1118/1.3477088 · Cited by 171 · cited 1×
“RESULTS In the following section, we evaluate MBIR with beamhardening correction (MBIR-BHC) using both simulated and real data sets, and we compare it to FBP, generic MBIR with a mono-energetic X-ray model (MBIR-mono), and the Empirical Beam Hardening Correction (EBHC) method [31].”
MethodEmpirical cupping correction: A first‐order raw data precorrection for cone‐beam computed tomography
Kachelrieß, M., Sourbelle, K., & Kalender, W. A. (2006) · Medical Physics · doi:10.1118/1.2188076 · Cited by 145
Reconstruction algorithm for polychromatic CT imaging: application to beam hardening correction
Yan, C. H., Whalen, R. T., Beaupré, G. S., et al. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.832955 · Cited by 144
Elbakri, I. A., & Fessler, J. A. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/15/314 · Cited by 137 · cited 1×
“[23], [24] developed an iterative reconstru c ion method based on the idea of material decomposition.”
MethodA Framework for Spectral Artifact Corrections in X-Ray CT
Stonestrom, J. P., Alvarez, R. E., & Macovski, A. (1981) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1981.324786 · Cited by 134 · cited 1×
“Another approach is dual energy scanning [11], [12].”
BackgroundZhang, R., Thibault, J., Bouman, C. A., et al. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2282370 · Cited by 124
Self-citationReducing non-linear artifacts of multi-material objects in industrial 3D computed tomography
Krumm, M., Kasperl, S., & Franz, M. (2008) · NDT & E International · doi:10.1016/j.ndteint.2007.12.001 · Cited by 123
Joseph, P. M., & Ruth, C. (1997) · Medical Physics · doi:10.1118/1.597970 · Cited by 111 · cited 1×
“, soft issue and bone) and the X-ray spectrum is known; so these iterative post-processing techniques can be effective [13], [15], [16].”
BackgroundPost-reconstruction method for beam hardening in computerised tomography
Nalcioglu, O., & Lou, R. (1979) · Physics in Medicine and Biology · doi:10.1088/0031-9155/24/2/009 · Cited by 102
A beam-hardening correction using dual-energy computed tomography
Coleman, A. J., & Sinclair, M. (1985) · Physics in Medicine and Biology · doi:10.1088/0031-9155/30/11/007 · Cited by 87
A model-based correction method for beam hardening artefacts in X-ray microtomography
de Casteele, E. V., Dyck, D. V., Sijbers, J., et al. (2004) · Journal of X-Ray Science and Technology · doi:10.3233/xst-2004-00100 · Cited by 78
An Inaccuracy in Computed Tomography: The Energy Dependence of CT Values
Zatz, L. M., & Alvarez, R. E. (1977) · Radiology · doi:10.1148/124.1.91 · Cited by 74
Polychromatic Streak Artifacts in Computed Tomography Images
Duerinckx, A. J., & Macovski, A. (1978) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-197809000-00020 · Cited by 72
A Comparative Study of Two Postreconstruction Beam Hardening Correction Methods
Herman, G. T., & Trivedi, S. S. (1983) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1983.4307626 · Cited by 70
Beam Hardening Correction for Middle-Energy Industrial Computerized Tomography
Gao, H., Zhang, L., Chen, Z., et al. (2006) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2006.879825 · Cited by 38
Statistical x-ray-computed tomography image reconstruction with beam- hardening correction
Elbakri, I. A., & Fessler, J. A. (2001) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.430961 · Cited by 15 · cited 1×
“[23], [24] developed an iterative reconstru c ion method based on the idea of material decomposition.”
MethodJin, P., Ye, D. H., & Bouman, C. A. (2015) · Proceedings - International Conference on Image Processing · doi:10.1109/icip.2015.7350909 · Cited by 14 · cited 1×
“Note that the joint MRF model for image and segmentation label has also been applied in CT artifact reduction and segmentation problem [43].”
MethodSelf-citationA new statistical image reconstruction algorithm for polyenergetic X-ray CT
Abella, M., & Fessler, J. A. (2009) · IEEE International Symposium on Biomedical Imaging: From Nano to Macro (ISBI) · doi:10.1109/isbi.2009.5193009 · Cited by 9
Simplified Statistical Image Reconstruction Algorithm for Polyenergetic X-Ray CT
Srivastava, S., & Fessler, J. A. (2006) · 2006 IEEE Nuclear Science Symposium Conference Record · doi:10.1109/nssmic.2005.1596614 · Cited by 6
Cited by
A review on medical imaging synthesis using deep learning and its clinical applications
Wang, T., Lei, Y., Fu, Y., Wynne, J. F., Curran, W. J., Liu, T., & Yang, X. (2021) · Journal of Applied Clinical Medical Physics · doi:10.1002/acm2.13121 · Cited by 279
Metadata
- Authors
- Jin, P., Bouman, C. A., & Sauer, K. D.
- Venue
- IEEE Transactions on Computational Imaging
- Published
- 2015-09
- Volume
- 1
- Issue
- 3
- Pages
- 200-216
- ISSN
- 2333-9403 (ISSN-L)
- 2334-0118
- OpenAlex
- W1944106919
- Cited by
- 164
- References
- 32
- FWCI
- 14.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.