The DOI matches its Crossref record.
Power harvesting and telemetry in CMOS for implanted devices
Abstract
Implanted sensors offer many advantages to study and monitor the human body. Wires or batteries often compromise their usefulness. We describe a telemetry chip that by inductive coupling supplies power to and transmits digital data from an implantable sensor. The same two coils are used to transmit both power and data. The chip fabricated in 0.5-/spl mu/m CMOS technology supplies 1.7 mA at 3.3 V, over a distance up to 25 mm between coils. Experiments emulating the effect of human tissue by introducing water bearing colloids between the two coils revealed a negligible loss of transfer efficiency. With modified Miller encoding, the data link attained 3 10/sup -5/ bit error rate at 10 kbps transmission speed over 25 mm distance. Repeated tests using the same colloids between coils resulted in a slight decrease in the signal to noise ratio of the data stream with increasing thickness.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Optimal Frequency for Wireless Power Transmission Into Dispersive Tissue
Poon, A. S. Y., O'Driscoll, S., & Meng, T. H. (2010) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2010.2044310 · Cited by 469
Wireless Power Transfer in Loosely Coupled Links: Coil Misalignment Model
Fotopoulou, K., & Flynn, B. W. (2011) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2010.2093534 · Cited by 391
Wireless power transfer techniques for implantable medical devices: a review
Khan, S. R., Pavuluri, S. K., Cummins, G., & Desmulliez, M. P. Y. (2020) · Sensors · doi:10.3390/s20123487 · Cited by 355
A Study on Magnetic Field Repeater in Wireless Power Transfer
Ahn, D., & Hong, S. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2188254 · Cited by 351
Maximum Achievable Efficiency in Near-Field Coupled Power-Transfer Systems
Zargham, M., & Gulak, P. G. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2174794 · Cited by 349
An Overview of Near Field UHF RFID
Nikitin, P., Rao, K. V. S., & Lazar, S. (2007) · 2007 IEEE International Conference on RFID · doi:10.1109/rfid.2007.346165 · Cited by 326
Energy harvesting for the implantable biomedical devices: issues and challenges
Hannan, M. A., Mutashar, S., Samad, S. A., & Hussain, A. (2014) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-13-79 · Cited by 322
A Review of In-Body Biotelemetry Devices: Implantables, Ingestibles, and Injectables
Kiourti, A., & Nikita, K. S. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2668612 · Cited by 278
Design of a Solar-Harvesting Circuit for Batteryless Embedded Systems
Brunelli, D., Moser, C., Thiele, L., & Benini, L. (2009) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2009.2015690 · Cited by 272
Guo, S., & Lee, H. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2020195 · Cited by 253
Zargham, M., & Gulak, P. G. (2015) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2328318 · Cited by 115
“These early implants were bulky and power hungry with high failure rates due to battery complications [1].”
Background
Metadata
- Authors
- Sauer, C., Stanacevic, M., Cauwenberghs, G., & Thakor, N.
- Venue
- IEEE Transactions on Circuits and Systems I: Regular Papers
- Published
- 2005-12
- Volume
- 52
- Issue
- 12
- Pages
- 2605-2613
- ISSN
- 1057-7122 (ISSN-L)
- OpenAlex
- W2072076450
- Cited by
- 249
- References
- 0
- FWCI
- 10.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.