The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Maximum Achievable Efficiency in Near-Field Coupled Power-Transfer Systems
Abstract
Wireless power transfer is commonly realized by means of near-field inductive coupling and is critical to many existing and emerging applications in biomedical engineering. This paper presents a closed form analytical solution for the optimum load that achieves the maximum possible power efficiency under arbitrary input impedance conditions based on the general two-port parameters of the network. The two-port approach allows one to predict the power transfer efficiency at any frequency, any type of coil geometry and through any type of media surrounding the coils. Moreover, the results are applicable to any form of passive power transfer such as provided by inductive or capacitive coupling. Our results generalize several well-known special cases. The formulation allows the design of an optimized wireless power transfer link through biological media using readily available EM simulation software. The proposed method effectively decouples the design of the inductive coupling two-port from the problem of loading and power amplifier design. Several case studies are provided for typical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optimal Frequency for Wireless Power Transmission Into Dispersive Tissue
Poon, A. S. Y., O'Driscoll, S., & Meng, T. H. (2010) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2010.2044310 · Cited by 469
Modeling and optimization of printed spiral coils in air, saline, and muscle tissue environments
Jow, U.-M., & Ghovanloo, M. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2025366 · Cited by 241
Lee, S. B., Lee, H.-M., Kiani, M., Jow, U.-M., & Ghovanloo, M. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2078814 · Cited by 220
Cited by
Wireless power transfer techniques for implantable medical devices: a review
Khan, S. R., Pavuluri, S. K., Cummins, G., & Desmulliez, M. P. Y. (2020) · Sensors · doi:10.3390/s20123487 · Cited by 355
A Review on the Recent Development of Capacitive Wireless Power Transfer Technology
Lu, F., Zhang, H., & Mi, C. (2017) · Energies · doi:10.3390/en10111752 · Cited by 282
Zargham, M., & Gulak, P. G. (2015) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2328318 · Cited by 115
Self-citationIbrahim, A., Meng, M., & Kiani, M. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2812420 · Cited by 83
Near-Field Wireless Power Transfer to Stent-Based Biomedical Implants
Wiseman, G., Redoute, J.-M., Ganesan, K., Rind, G. S., John, S. E., Ronayne, S. M., Opie, N. L., Garrett, D. J., & Prawer, S. (2018) · IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology · doi:10.1109/jerm.2018.2833386 · Cited by 49
Metadata
- Authors
- Zargham, M., & Gulak, P. G.
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2012-06
- Volume
- 6
- Issue
- 3
- Pages
- 228-245
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W2136256029
- Cited by
- 349
- References
- 3
- FWCI
- 15.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Maximum Achievable Efficiency in Near-Field Coupled Power-Transfer Systems. https://app.cochat.ai/papers/10.1109/tbcas.2011.2174794
- The paper
- Zargham, M., & Gulak, P. G. (2012). Maximum Achievable Efficiency in Near-Field Coupled Power-Transfer Systems. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2011.2174794
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.