Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.

Multistep Prediction of Physiological Tremor Based on Machine Learning for Robotics Assisted Microsurgery

Tatinati, Sivanagaraja, Veluvolu, Kalyana C., Wei Tech Ang · 2015 · IEEE Transactions on Cybernetics

Abstract

For effective tremor compensation in robotics assisted hand-held device, accurate filtering of tremulous motion is necessary. The time-varying unknown phase delay that arises due to both software (filtering) and hardware (sensors) in these robotics instruments adversely affects the device performance. In this paper, moving window-based least squares support vector machines approach is formulated for multistep prediction of tremor to overcome the time-varying delay. This approach relies on the kernel-learning technique and does not require the knowledge of prediction horizon compared to the existing methods that require the delay to be known as a priori. The proposed method is evaluated through simulations and experiments with the tremor data recorded from surgeons and novice subjects. Comparison with the state-of-the-art techniques highlights the suitability and better performance of the proposed method.

Overview

Integrity signals

Registry

Crossref · 10.1109/tcyb.2014.2381495

Cites

36 of 36 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 36 references

Research works printed but not linked: 2

  1. cauwenberghs, 2001, Advances in Neural Information Processing System
  2. elbe, 1985, Tremor

Cited by

See all 77

Metadata

Authors
Tatinati, S., Veluvolu, K. C., & Ang, W. T.
Affiliations
  • Kyungpook National University (KR)
  • Nanyang Technological University (SG)
Venue
IEEE Transactions on Cybernetics
Published
2015-02
Volume
45
Issue
2
Pages
328-339
ISSN
  • 2168-2267 (ISSN-L)
  • 2168-2275
OpenAlex
W1976018656
Cited by
77
References
36
Citations by year
2026: 2 · 2025: 8 · 2024: 8 · 2023: 5 · 2022: 6 · 2021: 7 · 2020: 9 · 2019: 9 · 2018: 4 · 2017: 3 · 2016: 9 · 2015: 7
FWCI
3.53
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Cybernetics (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Basic Science Research Program through the National Research Foundation of Korea (NRF)
  • Ministry of Education, Science, and Technology (NRF-2014R1A1A2A10056145)
Topics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
  • Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems
  • Physical Sciences › Engineering › Control and Systems Engineering › Iterative Learning Control Systems
Keywords
physiological tremor, tremor compensation, multi-step forecasting, least squares support vector machine, moving window, kernel learning, tremor filtering
MeSH terms
Computer Simulation, Humans, Microsurgery, Signal Processing, Computer-Assisted, Tremor, Models, Statistical, Support Vector Machine, Robotic Surgical Procedures

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Multistep Prediction of Physiological Tremor Based on Machine Learning for Robotics Assisted Microsurgery. https://app.cochat.ai/papers/10.1109/tcyb.2014.2381495
The paper
Tatinati, S., Veluvolu, K. C., & Ang, W. T. (2015). Multistep Prediction of Physiological Tremor Based on Machine Learning for Robotics Assisted Microsurgery. IEEE Transactions on Cybernetics. https://doi.org/10.1109/tcyb.2014.2381495

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.