Reduced Adaptive Fuzzy Decoupling Control for Lower Limb Exoskeleton
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
This article reports our study on a reduced adaptive fuzzy decoupling control for our lower limb exoskeleton system which typically is a multi-input-multi-output (MIMO) uncertain nonlinear system. To show the applicability and generality of the proposed control methods, a more general MIMO uncertain nonlinear system model is considered. By decoupling control, the entire MIMO system is separated into several MISO subsystems. In our experiments, such a system may have problems (even unstable) if a traditional fuzzy approximator is used to estimate the complicated coupling terms. In this article, to overcome this problem, a reduced adaptive fuzzy system together with a compensation term is proposed. Compared to traditional approaches, the proposed fuzzy control approach can reduce possible chattering phenomena and achieve better control performance. By employing the proposed control scheme to an actual 2-DOF lower limb exoskeleton rehabilitation robot system, it can be seen from the experimental results that, as expected, it has good performance to track the model trajectory of a human walking gait. Therefore, it can be concluded that the developed approach is effective for the control of a lower limb exoskeleton system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanical design of the Berkeley lower extremity exoskeleton (BLEEX)
Zoss, A. B., Kazerooni, H., & Chu, A. (2006) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2006.871087 · Cited by 1,170
Adaptive Neural Control of Uncertain MIMO Nonlinear Systems
Ge, S. S., & Wang, C. (2004) · IEEE Transactions on Neural Networks · doi:10.1109/tnn.2004.826130 · Cited by 971 · cited 2×
“1, ρ1 = ρ2 = 1, k1 = [100, 25], and k2 = 100.”
Robot assisted gait training with Active Leg Exoskeleton (ALEX)
Banala, S. K., Kim, S. H., Agrawal, S. K., & Scholz, J. P. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2008280 · Cited by 751
Adaptive Neural Control of MIMO Nonstrict-Feedback Nonlinear Systems With Time Delay
Zhao, X., Yang, H., Karimi, H. R., & Zhu, Y. (2016) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2015.2441292 · Cited by 130 · cited 1×
“nonlinear time-delay systems in [31] and [32].”
Cited by
Yang, Y., Huang, D., Ma, L., Liu, X., & Li, Y. (2024) · ISA Transactions · doi:10.1016/j.isatra.2024.06.001 · Cited by 10
Metadata
- Authors
- Sun, W., Lin, J.-W., Su, S.-F., Wang, N., & Er, M. J.
- Venue
- IEEE Transactions on Cybernetics
- Published
- 2021-03
- Volume
- 51
- Issue
- 3
- Pages
- 1099-1109
- ISSN
- 2168-2267 (ISSN-L)
- 2168-2275
- OpenAlex
- W3007437250
- Cited by
- 169
- References
- 4
- FWCI
- 13.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reduced Adaptive Fuzzy Decoupling Control for Lower Limb Exoskeleton. https://app.cochat.ai/papers/10.1109/tcyb.2020.2972582
- The paper
- Sun, W., Lin, J.-W., Su, S.-F., Wang, N., & Er, M. J. (2021). Reduced Adaptive Fuzzy Decoupling Control for Lower Limb Exoskeleton. IEEE Transactions on Cybernetics. https://doi.org/10.1109/tcyb.2020.2972582
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.