Reduced Adaptive Fuzzy Decoupling Control for Lower Limb Exoskeleton
The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
This article reports our study on a reduced adaptive fuzzy decoupling control for our lower limb exoskeleton system which typically is a multi-input-multi-output (MIMO) uncertain nonlinear system. To show the applicability and generality of the proposed control methods, a more general MIMO uncertain nonlinear system model is considered. By decoupling control, the entire MIMO system is separated into several MISO subsystems. In our experiments, such a system may have problems (even unstable) if a traditional fuzzy approximator is used to estimate the complicated coupling terms. In this article, to overcome this problem, a reduced adaptive fuzzy system together with a compensation term is proposed. Compared to traditional approaches, the proposed fuzzy control approach can reduce possible chattering phenomena and achieve better control performance. By employing the proposed control scheme to an actual 2-DOF lower limb exoskeleton rehabilitation robot system, it can be seen from the experimental results that, as expected, it has good performance to track the model trajectory of a human walking gait. Therefore, it can be concluded that the developed approach is effective for the control of a lower limb exoskeleton system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fuzzy basis functions, universal approximation, and orthogonal least-squares learning
Wang, L.-X., & Mendel, J. M. (1992) · IEEE Transactions on Neural Networks · doi:10.1109/72.159070 · Cited by 2,796 · cited 1×
“Adaptive fuzzy control [18]–[22] and neural”
Stable adaptive fuzzy control of nonlinear systems
Wang, L.-X. (1993) · IEEE Transactions on Fuzzy Systems · doi:10.1109/91.227383 · Cited by 1,617
Lower Extremity Exoskeletons and Active Orthoses: Challenges and State-of-the-Art
Dollar, A. M., & Herr, H. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.915453 · Cited by 1,327 · cited 1×
“The studies [4]–[9] and the references therein also made significant contributions to the research of exoskeleton.”
Biomechanical design of the Berkeley lower extremity exoskeleton (BLEEX)
Zoss, A. B., Kazerooni, H., & Chu, A. (2006) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2006.871087 · Cited by 1,170
Adaptive tracking control of uncertain MIMO nonlinear systems with input constraints
Chen, M., Ge, S. S., & Ren, B. (2011) · Automatica · doi:10.1016/j.automatica.2011.01.025 · Cited by 1,056
Adaptive Neural Control of Uncertain MIMO Nonlinear Systems
Ge, S. S., & Wang, C. (2004) · IEEE Transactions on Neural Networks · doi:10.1109/tnn.2004.826130 · Cited by 971 · cited 2×
“1, ρ1 = ρ2 = 1, k1 = [100, 25], and k2 = 100.”
Robot assisted gait training with Active Leg Exoskeleton (ALEX)
Banala, S. K., Kim, S. H., Agrawal, S. K., & Scholz, J. P. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2008280 · Cited by 751 · cited 2×
“With the combination of a treadmill and suspension system, the goal of physical rehabilitation is to help survivors regain the use of impaired limbs [3].”
Chen, M., Ge, S. S., & How, B. (2010) · IEEE Transactions on Neural Networks · doi:10.1109/tnn.2010.2042611 · Cited by 732
Patient- cooperative strategies for robot-aided treadmill training: first experimental results
Riener, R., Lunenburger, L., Jezernik, S., Anderschitz, M., Colombo, G., & Dietz, V. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.848628 · Cited by 729 · cited 1×
“The structure of the control plant used in this article is similar to that of the active leg exoskeleton used in [3] and the lokomat in [7].”
Farrell, J. A., & Polycarpou, M. M. (2006) · Wiley eBooks · doi:10.1002/0471781819 · Cited by 617
HAL: Hybrid Assistive Limb Based on Cybernics
Sankai, Y. (2010) · Springer Tracts in Advanced Robotics · doi:10.1007/978-3-642-14743-2_3 · Cited by 479 · cited 1×
“Hybrid assistive limb (HAL) is a walking aid system for individuals with gait disorders [2].”
Hybrid Control of the Berkeley Lower Extremity Exoskeleton (BLEEX)
Kazerooni, H., Steger, R., & Huang, L. (2006) · The International Journal of Robotics Research · doi:10.1177/0278364906065505 · Cited by 382 · cited 3×
“More specifically, for a BLEEX, a sensitivity amplification controller is presented in [10] to track the human’s trajectory without installing any sensor between the human and the exoskeleton.”
Adaptive Fuzzy Output Feedback Control of MIMO Nonlinear Systems With Unknown Dead-Zone Inputs
Tong, S., & Li, Y. (2012) · IEEE Transactions on Fuzzy Systems · doi:10.1109/tfuzz.2012.2204065 · Cited by 369
Adaptive robust control of MIMO nonlinear systems in semi-strict feedback forms
Yao, B., & Tomizuka, M. (2001) · Automatica · doi:10.1016/s0005-1098(01)00082-6 · Cited by 340 · cited 1×
“MIMO uncertain nonlinear systems have attracted much attention [14]–[17] in the past two decades.”
Sun, W., Su, S., Wu, Y., Xia, J., & Nguyen, V. (2019) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2018.2890256 · Cited by 333
Self-citationUnified iterative learning control for flexible structures with input constraints
He, W., Meng, T., He, X., & Ge, S. S. (2018) · Automatica · doi:10.1016/j.automatica.2018.06.051 · Cited by 322
Derivative and integral terminal sliding mode control for a class of MIMO nonlinear systems
Chiu, C.-S. (2012) · Automatica · doi:10.1016/j.automatica.2011.08.055 · Cited by 313 · cited 1×
“in [29] and [30] for MIMO nonlinear systems.”
Adaptive Fuzzy Control of Strict-Feedback Nonlinear Time-Delay Systems With Unmodeled Dynamics
Yin, S., Shi, P., & Yang, H. (2016) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2015.2457894 · Cited by 305
A hybrid adaptive fuzzy control for a class of nonlinear MIMO systems
Li, H., & Tong, S. (2003) · IEEE Transactions on Fuzzy Systems · doi:10.1109/tfuzz.2002.806314 · Cited by 292
Zhang, T., & Ge, S. S. (2009) · IEEE Transactions on Neural Networks · doi:10.1109/tnn.2008.2010349 · Cited by 286 · cited 1×
“networks control [23]–[25] have been developed to solve this problem.”
Li, Y., & Tong, S. (2017) · IEEE Transactions on Fuzzy Systems · doi:10.1109/tfuzz.2016.2574913 · Cited by 264 · cited 1×
“for MIMO uncertain switched nonstrict-feedback nonlinear systems is investigated in [33].”
Stable adaptive fuzzy controllers with application to inverted pendulum tracking
Wang, L.-X. (1996) · IEEE Transactions on Systems, Man, and Cybernetics, Part B (Cybernetics) · doi:10.1109/3477.537311 · Cited by 262 · cited 1×
“Similar to [53], if the adaptive laws of those dominant parameters θfi and θgii, and the coupling parameter θgij are”
Zhao, X., Yang, H., Xia, W., & Wang, X. (2017) · IEEE Transactions on Fuzzy Systems · doi:10.1109/tfuzz.2016.2594273 · Cited by 203 · cited 1×
“nonlinear time-delay systems in [31] and [32].”
Adaptive Neural Control of Uncertain MIMO Nonlinear Systems With State and Input Constraints
Chen, Z., Li, Z., & Chen, C. L. P. (2017) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2016.2538779 · Cited by 202
Observer design for a class of MIMO nonlinear systems
Farza, M., M'Saad, M., & Rossignol, L. (2004) · Automatica · doi:10.1016/j.automatica.2003.08.008 · Cited by 201 · cited 1×
“MIMO uncertain nonlinear systems have attracted much attention [14]–[17] in the past two decades.”
Neural PID Control of Robot Manipulators With Application to an Upper Limb Exoskeleton
Yu, W., & Rosén, J. (2012) · IEEE Transactions on Cybernetics · doi:10.1109/tsmcb.2012.2214381 · Cited by 186 · cited 2×
“Also in [13], a combination of a linear PID control method and a neural compensator strategy is proposed for an upper limb exoskeleton.”
Robust adaptive control for a class of mimo nonlinear systems with guaranteed error bounds
Xu, H., & Ioannou, P. (2003) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2003.811250 · Cited by 183
Li, Y., & Tong, S. (2017) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2016.2600263 · Cited by 173 · cited 1×
“Adaptive fuzzy control [18]–[22] and neural”
Assist-as-Needed Robot-Aided Gait Training Improves Walking Function in Individuals Following Stroke
Srivastava, S., Kao, P.-C., Kim, S. H., Stegall, P., Zanotto, D., Higginson, J. S., Agrawal, S. K., & Scholz, J. P. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2360822 · Cited by 168 · cited 1×
“For an exoskeleton system, similar to that of [47] and [48], a human walking gait pattern must be used as the system tracking reference.”
Wang, L., Li, H., Zhou, Q., & Lu, R. (2017) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2017.2684131 · Cited by 153
Adaptive Tracking Control of Wheeled Inverted Pendulums With Periodic Disturbances
Sun, W., Su, S., Xia, J., & Wu, Y. (2018) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2018.2884707 · Cited by 147 · cited 1×
“The studies in [34]–[37] and the references therein also report several control strategies for”
Self-citationChen, B., & Liu, X. (2005) · IEEE Transactions on Fuzzy Systems · doi:10.1109/tfuzz.2005.859322 · Cited by 137
Adaptive Neural Control of MIMO Nonstrict-Feedback Nonlinear Systems With Time Delay
Zhao, X., Yang, H., Karimi, H. R., & Zhu, Y. (2016) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2015.2441292 · Cited by 130 · cited 1×
“nonlinear time-delay systems in [31] and [32].”
Jin, X. (2016) · International Journal of Robust and Nonlinear Control · doi:10.1002/rnc.3596 · Cited by 115 · cited 1×
“The studies in [34]–[37] and the references therein also report several control strategies for”
Yang, Y. M., Ma, L., & Huang, D. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2622665 · Cited by 95 · cited 1×
“In [11], a repetitive learning control scheme is designed for the tracking control of a lower limb exoskeleton called CASWELL.”
A Controller for Guiding Leg Movement During Overground Walking With a Lower Limb Exoskeleton
Martínez, A., Lawson, B. E., & Goldfarb, M. T. (2017) · IEEE Transactions on Robotics · doi:10.1109/tro.2017.2768035 · Cited by 92
Kim, S., & Bae, J. (2017) · IEEE/ASME transactions on mechatronics · doi:10.1109/tmech.2017.2687979 · Cited by 91 · cited 1×
“The studies [4]–[9] and the references therein also made significant contributions to the research of exoskeleton.”
Almost disturbance decoupling of MIMO nonlinear systems and application to chemical processes
Liu, X., Jutan, A., & Rohani, S. (2003) · Automatica · doi:10.1016/j.automatica.2003.10.019 · Cited by 80 · cited 1×
“Then, in [40]–[42], the approach is extended to MIMO nonlinear systems with a nested lower triangular form.”
Toward Lower Limbs Functional Rehabilitation Through a Knee-Joint Exoskeleton
Rifaï, H., Mohammed, S., Djouani, K., & Amirat, Y. (2016) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2016.2565385 · Cited by 73
Youssofzadeh, V., Zanotto, D., Wong‐Lin, K., Agrawal, S. K., & Prasad, G. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2551642 · Cited by 51 · cited 1×
“For an exoskeleton system, similar to that of [47] and [48], a human walking gait pattern must be used as the system tracking reference.”
Design of a biologically inspired lower limb exoskeleton for human gait rehabilitation
Lyu, M., Chen, W., Ding, X., Wang, J., Bai, S., & Ren, H. (2016) · Review of Scientific Instruments · doi:10.1063/1.4964136 · Cited by 45 · cited 1×
“Since the 2-DOF lower limb exoskeleton is controlled by two motors, the end-effector trajectory must be designed by using inverse kinematic [49] to the joint degrees.”
Ortiz, J., Poliero, T., Cairoli, G., Graf, E. S., & Caldwell, D. G. (2017) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2017.2768119 · Cited by 45
Force Sensorless Compliance Control of a Lower-limb Exoskeleton Robot
Kuo, C., Yudha, A. P., & Mohapatra, S. K. (2018) · International Journal of Automation and Smart Technology · doi:10.5875/ausmt.v8i1.1565 · Cited by 3 · cited 1×
“The details can be referred to in [50].”
Cited by
Yang, Y., Huang, D., Ma, L., Liu, X., & Li, Y. (2024) · ISA Transactions · doi:10.1016/j.isatra.2024.06.001 · Cited by 10
Metadata
- Authors
- Sun, W., Lin, J.-W., Su, S.-F., Wang, N., & Er, M. J.
- Venue
- IEEE Transactions on Cybernetics
- Published
- 2021-03
- Volume
- 51
- Issue
- 3
- Pages
- 1099-1109
- ISSN
- 2168-2267 (ISSN-L)
- 2168-2275
- OpenAlex
- W3007437250
- Cited by
- 169
- References
- 43
- FWCI
- 13.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.