Fault-Tolerant Control of PMSM With Inter-Turn Short-Circuit Fault
The DOI matches its Crossref record; 34 of the 35 references it cites were found in a registry or an index.
Abstract
Fault diagnosis and fault tolerant (FT) control of electric drive systems have been extensively studied by many researchers. Naturally, one would like to use fault diagnosis information to improve FT control to achieve good post-fault performance while it is safe to do so. In this paper, a novel FT control method is proposed for permanent magnet synchronous motor with inter-turn short circuit fault. Given fault severity, the proposed FT control can reduce torque ripple while keeping reasonable torque output. The theoretical derivation, simulation, and experimental validation are presented in this paper.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This method is based on the reference current signal injection.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [183]
In the citing paper
“However, the proposed method is based on a perfect knowledge of motor parameters, together with actual number of shorted turns and short-circuit resistance, that is difficult to determine in an industrial application.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [183]
In the citing paper
“However, if the fault is detected the FTC method can be applied in order to decrease the level of the oscillations arising after the fault, e.g.[183].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [183]
Citations
Cites
Recent Advances in Modeling and Online Detection of Stator Interturn Faults in Electrical Motors
Gandhi, A., Corrigan, T., & Parsa, L. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2089937 · Cited by 544
Cruz, S. M. A., & Cardoso, A. J. M. (2001) · IEEE Transactions on Industry Applications · doi:10.1109/28.952496 · Cited by 464
Detection and location of interturn short circuits in the stator windings of operating motors
Penman, J., Sedding, H. G., Lloyd, B. A., & Fink, W. T. (1994) · IEEE Transactions on Energy Conversion · doi:10.1109/60.368345 · Cited by 394
A strategy for improving reliability of field-oriented controlled induction motor drives
Liu, T.-H., Fu, J.-R., & Lipo, T. A. (1993) · IEEE Transactions on Industry Applications · doi:10.1109/28.245714 · Cited by 374 · cited 1×
“A common and intuitive method is to cut off the faulty phase and operate the motor with the remaining windings [27]–[29].”
MethodHang, J., Zhang, J., Cheng, M., & Huang, J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2388493 · Cited by 218
Self-citationControl Algorithms for a Fault-Tolerant PMSM Drive
Wallmark, O., Harnefors, L., & Carlson, O. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.895076 · Cited by 197
An Early Stage Interturn Fault Diagnosis of PMSMs by Using Negative-Sequence Components
Jeong, H., Moon, S., & Kim, S. W. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2677355 · Cited by 141
Dynamic Modeling and Control for SPMSMs With Internal Turn Short Fault
Jeong, I., Hyon, B. J., & Nam, K. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2222049 · Cited by 128 · cited 2×
“The two drawbacks in [30] will be addressed in this paper.”
BackgroundA Comprehensive Analysis of Short-Circuit Current Behavior in PMSM Interturn Short-Circuit Faults
Qi, Y., Bostanci, E., Gurusamy, V., & Akin, B. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2809668 · Cited by 128 · cited 1×
“The physical structure of inter-turn SC fault can be found in [4], [5].”
BackgroundSeverity Estimation of Interturn Short Circuit Fault for PMSM
Yuan, Q., Bostancı, E., Zafarani, M., & Akin, B. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2879281 · Cited by 116 · cited 1×
“proposed a method to estimate number of short circuit turns at standstill condition [26].”
Method
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
Bhuiyan, E. A., Akhand, M. M. A., Das, S. K., Ali, M. F., Tasneem, Z., Islam, M. R., Saha, D. K., Badal, F. R., Ahamed, M. H., & Moyeen, S. I. (2020) · International Journal of Automation and Computing · doi:10.1007/s11633-020-1250-3 · Cited by 68
Cheng, M., Zhou, J., Qian, W., Wang, B., Zhao, C., & Han, P. (2024) · Chinese Journal of Electrical Engineering · doi:10.23919/cjee.2023.000048 · Cited by 87
“AFTC methods are currently more applicable and have given rise to specific AFTC methods targeting various fault issues, such as those related to voltage inverter faults [126] , inter-turn short circuit faults [127] , and sensor failures [128] .”
Hang, J., Ding, S., Ren, X., Hu, Q., Huang, Y., Hua, W., & Wang, Q. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3073774 · Cited by 61
Integration of Interturn Fault Diagnosis and Fault-Tolerant Control for PMSM Drive System
Hang, J., Sun, W., Hu, Q., Ren, X., & Ding, S. (2021) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2021.3134821 · Cited by 58
“In [30], an FT control method is presented by the current injection strategy, where the short-circuited turn ratio and fault current are known in advance.”
BackgroundMethodInfluentialHang, J., Wang, X., Li, W., & Ding, S. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3484469 · Cited by 56
“In [31], to suppress the torque pulsations, an FT control method for current injection by considering fault currents is proposed.”
Tian, B., Molinas, M., An, Q., Zhou, B., & Wei, J. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2021.3053891 · Cited by 56
Xu, Z., Zhang, J., Xiong, J., Wu, Y., & Cheng, M. (2022) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2022.3225686 · Cited by 45
“It is of great importance to improve the reliability of the PMSMs with certain technologies, such as condition monitoring with fault detection [3].”
BackgroundInfluentialSelf-citationOnline Stator Inter-Turn Short Circuit Estimation and Fault Management in Permanent Magnet Motors
Baruti, K. H., Li, C., Erturk, F., & Akin, B. (2022) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2022.3220544 · Cited by 44
“A fault-tolerant control for PMSM motors with ITSC is proposed in [24].”
BackgroundInduction motor fault detection based on multi‐sensory control and wavelet analysis
Abubakar, U., Mekhilef, S., Gaeid, K. S., Mokhlis, H., & Mashhadany, Y. I. M. A. (2020) · IET Electric Power Applications · doi:10.1049/iet-epa.2020.0030 · Cited by 39
Krzysztofiak, M., Skowron, M., & Orlowska-Kowalska, T. (2020) · Energies · doi:10.3390/en14010153 · Cited by 33
“In [22], the authors present the impact of a coil short-circuit on the field-oriented control (FOC) structure, also presenting the possibility of torque ripple compensation.”
BackgroundFeng, G., Lai, C., & Kar, N. C. (2020) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2020.2992487 · Cited by 33
Inter-Turn Fault Diagnosis and Control for Five-Phase PMSMs by Disturbance Observer
Chen, Q., Han, X., Liu, G., Zhao, W., & Shi, H. T. H. (2024) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2024.3374364 · Cited by 31
“In [20], a fault-tolerant control considering fault currents is proposed to suppress torque ripple by the current injection method, but it requires a known fault severity of the motor.”
MethodCommon Predictive Model for PMSM Drives With Interturn Fault Considering Torque Ripple Suppression
Li, W., Hang, J., Ding, S., & Wang, Q. (2022) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2022.3232820 · Cited by 32
Forstner, G., Kugi, A., & Kemmetmüller, W. (2021) · Control Engineering Practice · doi:10.1016/j.conengprac.2021.104846 · Cited by 22
Tian, B., Wei, J., Molinas, M., Lu, R., An, Q., & Zhou, B. (2022) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2022.3195289 · Cited by 20
“The mutual inductances between segments AX and XN can be modeled as [30]–[32]”
BackgroundInfluentialZhang, J., Zhan, W., & Ehsani, M. (2023) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2023.3239426 · Cited by 22
“The fault detection method proposed in this brief can also be used in combination with other FTC method such as the one in [28].”
BackgroundMethodResultInfluentialSelf-citationChen, Q., Gu, L., Wang, J., Zhao, W., & Liu, G. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3162847 · Cited by 18
“In [23], injecting currents at the natural coordinate system, the inter-turn short-circuit current can”
BackgroundYang, J., & Delpha, C. (2022) · Signal Processing · doi:10.1016/j.sigpro.2022.108657 · Cited by 17
Zheng, P., Liu, W., Gao, Y., Tong, C., & Sui, Y. (2025) · CES Transactions on Electrical Machines and Systems · doi:10.30941/cestems.2025.00022 · Cited by 21
Interturn Short-Circuit Fault Detection of a Five-Phase Permanent Magnet Synchronous Motor
Yang, Z., & Chen, Y. (2021) · Energies · doi:10.3390/en14020434 · Cited by 15
“First of all, some of the detection methods are aimed at the steady-state operation of the PMSM, and the detection effect is not obvious when the PMSM is in transient operation [23,24].”
BackgroundLaamari, Y., Allaoui, S., Abdelmalik, A., & Saad, S. (2021) · Mathematical Modelling and Engineering Problems · doi:10.18280/mmep.080220 · Cited by 18
“In addition, the mutual inductance in the same phase between the winding in short circuits and the winding in healthy state also needs to be taken into account [13, 19].”
A Passive Inter Turn Short Circuit Fault Mitigation Technique for Electric Machines
Daniar, A., Khan, S. A., & Gardner, M. C. (2023) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2023.3278231 · Cited by 13
“Another current-injection-basedfaulttolerantcontrolmethodisproposed in [17] to minimize the torque ripple caused by ITSC faults.”
BackgroundTang, M., Odhano, S., Formentini, A., & Zanchetta, P. (2020) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2020.2989681 · Cited by 12
“When compared with the methods proposed in [13] and [14], the main differences are as follows.”
BackgroundResultA Photovoltaic-Fed Z-Source Inverter Motor Drive with Fault-Tolerant Capability for Rural Irrigation
Sharma, V., Hossain, M. J., Ali, S. M. N., & Kashif, M. (2020) · Energies · doi:10.3390/en13184630 · Cited by 12
Diagnostics of Interturn Short Circuits in PMSMs With Online Fault Indicators Estimation
Zezula, L., Kozovský, M., & Bláha, P. (2024) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2024.3363775 · Cited by 17
“Attaining such demands with a single diagnostic algorithm enables the advanced fault mitigation methods [11], [12], [13], [14] to function, thus enhancing the fault-tolerant control capabilities.”
BackgroundZheng, Z., Li, Q., Li, X., Zheng, P., Wang, K., & Cui, P. (2022) · Energy Reports · doi:10.1016/j.egyr.2022.05.123 · Cited by 9
Yang, J., & Delpha, C. (2023) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2023.110803 · Cited by 7
Xiao, F., Mai, Z., Liu, J., & Lian, C. (2020) · IET Electric Power Applications · doi:10.1049/iet-epa.2020.0114 · Cited by 7
Fault-Tolerant Control of Dual Three-Phase PMSM Drives with Inter-Turn Short-Circuit Fault
Cao, C., Wang, Z., Duan, C., & Wang, X. (2021) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/sdemped51010.2021.9605535 · Cited by 7
Kushwaha, A. A., Endla, N. K., & Fernandes, B. G. (2023) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2023.3270304 · Cited by 7
“limitation can be addressed using power electronic control, given the availability of vast literature on techniques for torque ripple mitigation [18], [19], [20], [21].”
BackgroundMethodA Speed Sensor Fault Tolerant Control for a Permanent Magnet Synchronous Motor
Salem, M. H., Bensalem, Y., & Abdelkrim, M. N. (2020) · International Multi-Conference on Systems, Signals & Devices (SSD) · doi:10.1109/ssd49366.2020.9364188 · Cited by 6
“Over the last few years, the PMSMs are increasingly used in industrial applications due to its high speed, high eciency, light weight, low cost and long-lasting operation [1,2].”
BackgroundKulkarni, S., & Thosar, A. (2022) · International Journal of Electrical and Electronics Research · doi:10.37391/ijeer.100240 · Cited by 6
Daniar, A., Khan, S. A., & Gardner, M. C. (2024) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2024.3411827 · Cited by 6
“Another current-injection-based fault tolerant control method is proposed in [29] to minimize the torque ripple caused by ITSC faults.”
Zhou, Y., Yan, L., Wei, X., & Hamad, M. S. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2025.3589453 · Cited by 5
“In addition, the short circuit of power semiconductor devices, the loss of gate control signals, and the disconnection of cables between PMSMs and inverters can also be converted into open-phase fault for processing [6], [7].”
Emulation of a Permanent Magnet Synchronous Machine with Stator Winding Fault
Kalarikkal, N., Boby, M., & Pillay, P. (2023) · IEEE International Conference on Power Electronics and Drive Systems (PEDS) · doi:10.1109/peds57185.2023.10246704 · Cited by 5
“Research on PMSM with ITSC fault has been discussed in [9-16].”
BackgroundPostal, G., Belie, F. D., & Gyselinck, J. J. C. (2023) · IEEE Student Conference on Electric Machines and Systems (SCEMS) · doi:10.1109/scems60579.2023.10379256 · Cited by 5
“Moreover, such models can also support the development of fault tolerant control methods [13] and severity estimation algorithms [14], [15].”
BackgroundWang, H., Hu, J., & Li, Y. (2023) · IEEE International Conference on Predictive Control of Electrical Drives and Power Electronics (PRECEDE) · doi:10.1109/precede57319.2023.10174329 · Cited by 4
“In [18], the compensating current was calculated by fault model and a modified field-oriented control (FOC) of three-phase PMSMs was proposed.”
MethodFFT Tool for Stator Winding Fault Detection: Application to a Permanent Magnet Synchronous Motor
Pacha, F. Z. H., Herizi, A., Fezai, N., & Amor, A. B. (2023) · IEEE International Conference on Advanced Systems and Emergent Technologies (IC_ASET) · doi:10.1109/ic_aset58101.2023.10151088 · Cited by 6
“As reported in reference [7], a short circuit fault accounts for 30-40% of faults in PMSMs.”
BackgroundPostal, G., Belie, F. D., & Gyselinck, J. J. C. (2025) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2025.3559020 · Cited by 3
“Moreover,suchhighfidelitymodelscanalsosupportthe developmentoffaulttolerantcontrolmethods[19]andseverity estimationalgorithms[20],[21].”
Xing, Z., Gao, Y., Chen, M., & Xu, J. (2021) · IEEE China International Youth Conference on Electrical Engineering (CIYCEE) · doi:10.1109/ciycee53554.2021.9676777 · Cited by 4
Tian, B., Lu, R., Wei, J., Molinas, M., Wang, K., & Zhang, Z. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3298780 · Cited by 2
“When μA and μB be the ratio of faulted coils with respect to phases A and B, this 7×7 inductance matrix can be represented by the following equation [32], [33], [34]: Additionally, the involved back EMFs and resistances are remodeled as follows (7) as shown at the bottom of the next page:”
BackgroundDaniar, A., Gardner, M. C., Sajadi, R., & Khan, S. A. (2024) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2024.3478213 · Cited by 3
“Additionally, another fault-tolerant control method based on current injection is proposed in [16] to mitigate torque ripple induced by ITSC faults.”
Fault Diagnosis of Stepping Motor PLC Control Loop Based on Fuzzy ADRC
Di, C.-Y. (2022) · Lecture notes of the Institute for Computer Sciences, Social Informatics and Telecommunications Engineering · doi:10.1007/978-3-030-94551-0_48 · Cited by 2
Fault tolerant control of a three‐phase PMSM by limiting the heat of an inter‐turn fault
Foitzik, S., & Doppelbauer, M. (2021) · IET Electric Power Applications · doi:10.1049/elp2.12142 · Cited by 3
“The authors in [6] developed a fault tolerant control, to reduce the torque ripple caused by an inter‐turn fault.”
Kumar, L., Nadarajan, S., Gupta, A. K., & Nguyen, H. D. (2023) · IEEE Journal of Emerging and Selected Topics in Industrial Electronics · doi:10.1109/jestie.2023.3319991 · Cited by 3
“The fault-tolerant operation mainly focus on having redundant system to reduce the torque ripple by injecting current through the phases in the field-oriented control (FOC) scheme, with reasonable power to continue the postfault operation [14].”
BackgroundFault-Tolerant Control of Dual Three-Phase PMSM Drives with Inter- Turn Short-Circuit Fault
Cao, C., Wang, Z., Duan, C., & Wang, X. (2022) · IEEE China International Youth Conference on Electrical Engineering (CIYCEE) · doi:10.1109/ciycee55749.2022.9958994 · Cited by 1
“In [8], the current reference value is changed to reduce the torque ripple for a SPMSM.”
BackgroundMethodInfluentialAhn, J., Lee, J., & Kim, H. (2025) · Applied Sciences · doi:10.3390/app15116065 · Cited by 1
Ismail, H. S., Daniar, A., & Gardner, M. C. (2025) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2025.3605455 · Cited by 1
“Several studies have investigated current injection methods for mitigating ITSC fault currents by reducing the fl ux linkage in the shorted turn [8], [15], [16], [17], [18], [19].”
Field Reconstruction of PMSM Demagnetization Fault Based on Gappy-POD
Zheng, T., Zhou, Y., Ran, X., Yan, S., Xu, X., & Ren, Z. (2025) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2025.3631013 · Cited by 1
“…demagnetization condition; however, the latter is necessary to build the motor model which can be used, for example, in fault-tolerant control [2] or to determine the amplitude of magnetizing current in the postassembly magnetization technique [3] which provides a way to remagnetize the…”
Fault Diagnosis and Adaptive Fault-Tolerant Control of Interturn Short-Circuit Fault in PMSM Drives
Zhang, Y., Wang, X., Peng, J., Kong, L., Wang, Z., & Mao, Y. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3645891 · Cited by 6
“Zhang et al. [23] analyze the relationships between short-circuit current and torque ripple to avoid the auxiliary circuit dependence.”
InfluentialComparative study of healthy PMSM and an Inter-turn short-circuited PMSM in Electric vehicles
Romdhane, M., Mohamed, N., Mansouri, A., Alshammari, B. M., & Guesmi, T. (2025) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.23919/icems66262.2025.11316928 · Cited by 1
“As a result, the winding where the fault occurs is split into two parts [14] : a1 is the sub - winding of the healthy part, and a2 is the sub - winding of the short - circuited part.”
Guo, L., Wang, K., Li, F., Zhu, S., & Cao, R. (2025) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2025.3534752 · Cited by 1
“even causes unexpected shutdown [9], [10].”
Online Monitoring of Interturn Short Circuit Current in PMSMs
Zezula, L., & Bláha, P. (2024) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon55916.2024.10905190 · Cited by 1
2019 Index IEEE Transactions on Energy Conversion Vol. 34
(2019) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2020.2965755 · Cited by 1
Monitoring of bearing fatigue life based on hidden Markov model
Hu, J., & Deng, S. (2021) · Journal of Intelligent & Fuzzy Systems · doi:10.3233/jifs-189815
Fault Diagnosis Method for Intertum Short Circuit of Power Network Condenser
Li, W., & Sun, G. (2021) · International Forum on Electrical Engineering and Automation (IFEEA) · doi:10.1109/ifeea54171.2021.00082
Xue, J., Zhang, H., Hua, W., & Li, X. (2023) · IEEE International Electrical and Energy Conference (CIEEC) · doi:10.1109/cieec58067.2023.10166453
Cui, R., Ji, Q., Zhang, S., & Li, H. (2025) · Sensors · doi:10.3390/s25247655
“Current-injection-based FTC has also been proposed for PMSMs, where the injected sequence components suppress ITSC-induced torque ripple while maintaining acceptable torque output [31].”
Pai, F., & Chiang, C.-K. (2026) · Energies · doi:10.3390/en19010248 · Cited by 2
Analysis and Suppression of Torque Harmonics in PMSM with High Resistance Connection Fault
Zhi, J., He, Y., Dai, D., Zhang, W., Xu, M., & Gerada, D. (2026) · IEEJ Transactions on Electrical and Electronic Engineering · doi:10.1002/tee.70328
Li, W., Du, Y., Hu, J., & Wang, Z. (2026) · IEEE International Electrical and Energy Conference (CIEEC) · doi:10.1109/cieec69682.2026.11571947
“Previous methods for torque ripple suppression typically utilize the change in zero-sequence voltage component (ZSVC) before and after faults, combined with current injection to suppress torque ripple [20], [21].”
Comparative Framework for Inter-Turn Short-Circuit Fault-Tolerant Control in EV PMSM Drives
Golla, A., Ibrahim, M., Mangels, M., Rassõlkin, A., & Kammermann, J. (2026) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/pemc69244.2026.11726051
“These compensating currents restore torque smoothness, balance electromagnetic forces, and reduce fault-induced thermal stress [6], [7], [15].”
Metadata
- Authors
- Zhang, J., Zhan, W., & Ehsani, M.
- Affiliations
- Texas A&M University (US)
- Venue
- IEEE Transactions on Energy Conversion
- Published
- 2019-12
- Volume
- 34
- Issue
- 4
- Pages
- 2267-2275
- ISSN
- 0885-8969 (ISSN-L)
- 1558-0059
- OpenAlex
- W2969715697
- Cited by
- 64
- References
- 35
- Citations by year
- 2026: 4 · 2025: 10 · 2024: 7 · 2023: 12 · 2022: 11 · 2021: 11 · 2020: 8 · 2019: 1
- FWCI
- 2.79
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Transactions on Energy Conversion (publishedVersion)
- OakTrust (Texas A&M University Libraries) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Keywords
- fault-tolerant control, permanent magnet synchronous motor, inter-turn short-circuit fault, fault diagnosis, torque ripple reduction, electric drives
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.