Fault-Tolerant Control of PMSM With Inter-Turn Short-Circuit Fault
The DOI matches its Crossref record; 34 of the 35 references it cites were found in a registry or an index.
Abstract
Fault diagnosis and fault tolerant (FT) control of electric drive systems have been extensively studied by many researchers. Naturally, one would like to use fault diagnosis information to improve FT control to achieve good post-fault performance while it is safe to do so. In this paper, a novel FT control method is proposed for permanent magnet synchronous motor with inter-turn short circuit fault. Given fault severity, the proposed FT control can reduce torque ripple while keeping reasonable torque output. The theoretical derivation, simulation, and experimental validation are presented in this paper.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This method is based on the reference current signal injection.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [183]
In the citing paper
“However, the proposed method is based on a perfect knowledge of motor parameters, together with actual number of shorted turns and short-circuit resistance, that is difficult to determine in an industrial application.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [183]
In the citing paper
“However, if the fault is detected the FTC method can be applied in order to decrease the level of the oscillations arising after the fault, e.g.[183].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [183]
Citations
Cites
Recent Advances in Modeling and Online Detection of Stator Interturn Faults in Electrical Motors
Gandhi, A., Corrigan, T., & Parsa, L. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2089937 · Cited by 544
Cruz, S. M. A., & Cardoso, A. J. M. (2001) · IEEE Transactions on Industry Applications · doi:10.1109/28.952496 · Cited by 464
Detection and location of interturn short circuits in the stator windings of operating motors
Penman, J., Sedding, H. G., Lloyd, B. A., & Fink, W. T. (1994) · IEEE Transactions on Energy Conversion · doi:10.1109/60.368345 · Cited by 394
A strategy for improving reliability of field-oriented controlled induction motor drives
Liu, T.-H., Fu, J.-R., & Lipo, T. A. (1993) · IEEE Transactions on Industry Applications · doi:10.1109/28.245714 · Cited by 374 · cited 1×
“A common and intuitive method is to cut off the faulty phase and operate the motor with the remaining windings [27]–[29].”
MethodHang, J., Zhang, J., Cheng, M., & Huang, J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2388493 · Cited by 218
Self-citationControl Algorithms for a Fault-Tolerant PMSM Drive
Wallmark, O., Harnefors, L., & Carlson, O. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.895076 · Cited by 197
An Early Stage Interturn Fault Diagnosis of PMSMs by Using Negative-Sequence Components
Jeong, H., Moon, S., & Kim, S. W. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2677355 · Cited by 141
Dynamic Modeling and Control for SPMSMs With Internal Turn Short Fault
Jeong, I., Hyon, B. J., & Nam, K. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2222049 · Cited by 128 · cited 2×
“The two drawbacks in [30] will be addressed in this paper.”
BackgroundA Comprehensive Analysis of Short-Circuit Current Behavior in PMSM Interturn Short-Circuit Faults
Qi, Y., Bostanci, E., Gurusamy, V., & Akin, B. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2809668 · Cited by 128 · cited 1×
“The physical structure of inter-turn SC fault can be found in [4], [5].”
BackgroundSeverity Estimation of Interturn Short Circuit Fault for PMSM
Yuan, Q., Bostancı, E., Zafarani, M., & Akin, B. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2879281 · Cited by 116 · cited 1×
“proposed a method to estimate number of short circuit turns at standstill condition [26].”
Method
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
Bhuiyan, E. A., Akhand, M. M. A., Das, S. K., Ali, M. F., Tasneem, Z., Islam, M. R., Saha, D. K., Badal, F. R., Ahamed, M. H., & Moyeen, S. I. (2020) · International Journal of Automation and Computing · doi:10.1007/s11633-020-1250-3 · Cited by 68
Cheng, M., Zhou, J., Qian, W., Wang, B., Zhao, C., & Han, P. (2024) · Chinese Journal of Electrical Engineering · doi:10.23919/cjee.2023.000048 · Cited by 87
“AFTC methods are currently more applicable and have given rise to specific AFTC methods targeting various fault issues, such as those related to voltage inverter faults [126] , inter-turn short circuit faults [127] , and sensor failures [128] .”
Hang, J., Ding, S., Ren, X., Hu, Q., Huang, Y., Hua, W., & Wang, Q. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3073774 · Cited by 61
Integration of Interturn Fault Diagnosis and Fault-Tolerant Control for PMSM Drive System
Hang, J., Sun, W., Hu, Q., Ren, X., & Ding, S. (2021) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2021.3134821 · Cited by 58
“In [30], an FT control method is presented by the current injection strategy, where the short-circuited turn ratio and fault current are known in advance.”
BackgroundMethodInfluential
Metadata
- Authors
- Zhang, J., Zhan, W., & Ehsani, M.
- Affiliations
- Texas A&M University (US)
- Venue
- IEEE Transactions on Energy Conversion
- Published
- 2019-12
- Volume
- 34
- Issue
- 4
- Pages
- 2267-2275
- ISSN
- 0885-8969 (ISSN-L)
- 1558-0059
- OpenAlex
- W2969715697
- Cited by
- 64
- References
- 35
- Citations by year
- 2026: 4 · 2025: 10 · 2024: 7 · 2023: 12 · 2022: 11 · 2021: 11 · 2020: 8 · 2019: 1
- FWCI
- 2.79
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Transactions on Energy Conversion (publishedVersion)
- OakTrust (Texas A&M University Libraries) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Keywords
- fault-tolerant control, permanent magnet synchronous motor, inter-turn short-circuit fault, fault diagnosis, torque ripple reduction, electric drives
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.