The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Online Interturn Fault Diagnosis of Permanent Magnet Synchronous Machine Using Zero-Sequence Components
Abstract
This paper develops an online interturn fault diagnosis method for permanent magnet synchronous machine (PMSM). The mathematical model of the PMSM with interturn fault is established. The zero-sequence voltage component and zero-sequence current component are analyzed in the PMSM, respectively. Then, the new fault indicators are defined to remove the influence of the variation of the rotor speed and an effective frequency tracking algorithm is presented to extract fault indicators. In this proposed method, not only the interturn fault can be effectively detected, but also the phase in which this fault occurs can be accurately identified. The experiments are carried out and the experiment results verify the effectiveness of the proposed method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Da, Y., Shi, X., & Krishnamurthy, M. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2227808 · Cited by 303
Sarikhani, A., & Mohammed, O. A. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2222857 · Cited by 177
Synchronous Demodulation of Control Voltages for Stator Interturn Fault Detection in PMSM
Boileau, T., Leboeuf, N., Nahid-Mobarakeh, B., & Meibody-Tabar, F. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2254132 · Cited by 90
Urresty, J.-C., Riba, J.-R., & Romeral, L. (2012) · Electric Power Systems Research · doi:10.1016/j.epsr.2012.02.012 · Cited by 73
Hang, J., Zhang, J., Cheng, M., & Wang, Z. (2013) · 2013 IEEE Energy Conversion Congress and Exposition · doi:10.1109/ecce.2013.6647169 · Cited by 36 · cited 1×
“Finally, well-known tools like fast Fourier transform [25], [26], order tracking filtering [27], empirical mode decomposition [24], [28], wavelet transform [20], [29], and Wigner–Ville Distribution [30] are applied to extract fault indicator.”
MethodSelf-citation
Research works printed but not linked: 30
- 10.1109/TIE.2012.2207655 · DOI · Paper page
- wei, 2012, Wind speed and rotor position sensorless control for direct-drive PMG wind turbines, IEEE Trans Ind Appl, 48, 3, 10.1109/TIA.2011.2175877 · DOI
- 10.1109/TMAG.2010.2096202 · doi:10.1109/tmag.2010.2096202
- 10.1109/TIE.2013.2286581 · DOI
- 10.1109/TPEL.2014.2301167 · DOI
- 10.1109/TPEL.2012.2212916 · DOI · Paper page
- 10.1109/28.952496 · DOI · Paper page
- 10.1109/TIE.2010.2064276 · DOI
- 10.1049/iet-epa.2009.0264 · DOI
- 10.1109/TIA.2009.2018905 · DOI
- 10.1109/TIA.2011.2168929 · DOI · Paper page
- 10.1109/TEC.2005.847976 · DOI
- 10.1109/TIA.2003.816531 · DOI · Paper page
- 10.1109/TIE.2010.2060463 · DOI · Paper page
- 10.1109/TIE.2008.2011580 · DOI · Paper page
- cheng, 2014, General requirement of traction motor drives, Automotive Encyclopedia, 10.1002/9781118354179.auto041 · DOI
- 10.1109/TPEL.2012.2198077 · DOI · Paper page
- 10.1109/TPEL.2013.2266377 · DOI
- 10.1016/j.rser.2007.05.008 · DOI · Paper page
- 10.1049/ip-epa:20010588 · DOI · Paper page
- 10.1109/2943.715501 · DOI
- 10.1109/TIE.2013.2284148 · DOI
- 10.1109/60.790920 · DOI · Paper page
- 10.1016/j.enconman.2014.08.037 · DOI · Paper page
- 10.1109/TIE.2007.911960 · DOI · Paper page
- 10.1109/TIE.2010.2089937 · DOI · Paper page
- 10.1109/TIE.2010.2062480 · DOI · Paper page
- urresty, 0, Detection of inter-turns short circuits in permanent magnet synchronous motors operating under transient conditions by means of the zero sequence voltage, Proc Eur Conf Power Electron Appl, 1
- 10.1109/TEC.2013.2292505 · doi:10.1109/tec.2013.2292505
- 10.1109/IAS.2004.1348496 · DOI
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
Motor Fault Diagnostics Based on Current Signatures: A Review
Niu, G., Dong, X., & Chen, Y. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3285999 · Cited by 269
Moon, S., Jeong, H., Lee, H., & Kim, S. W. (2018) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2017.2726142 · Cited by 123
Comprehensive review on inter‐turn fault indexes in permanent magnet motors
Faiz, J., Nejadi‐Koti, H., & Valipour, Z. (2017) · IET Electric Power Applications · doi:10.1049/iet-epa.2016.0196 · Cited by 86
Chen, Z., Liang, D., Jia, S., Yang, L., & Yang, S. (2023) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2023.3255249 · Cited by 72
Metadata
- Authors
- Hang, J., Zhang, J., Cheng, M., & Huang, J.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2015-12
- Volume
- 30
- Issue
- 12
- Pages
- 6731-6741
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2033802545
- Cited by
- 218
- References
- 5
- FWCI
- 11.14
- Type
- journal article
- Language
- en
- Open access
- closed
- Funders
- National Basic Research Program of China (973 Program) (2013CB035603)
- National Natural Science Foundation of China (51137001, 51320105002)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Online Interturn Fault Diagnosis of Permanent Magnet Synchronous Machine Using Zero-Sequence Components. https://app.cochat.ai/papers/10.1109/tpel.2015.2388493
- The paper
- Hang, J., Zhang, J., Cheng, M., & Huang, J. (2015). Online Interturn Fault Diagnosis of Permanent Magnet Synchronous Machine Using Zero-Sequence Components. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2015.2388493
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.