The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Performance Assessment of A Novel Vertical Dielectrically Modulated TFET-Based Biosensor
Abstract
A vertical dielectrically modulated tunnel field-effect transistor (V-DMTFET) as a label-free biosensor has been investigated in this paper for the first time and compared with lateral DMTFET (L-DMTFET) using underlap concept and gate work function engineering. To improve the performance of lateral biosensor (LB), a heavily doped front gate n+-pocket and gate-to-source overlap is introduced in the vertical biosensor (VB). The integrated effect of lateral tunneling as well as vertical tunneling in VB leads to enhanced ON-state current and decrease the subthreshold swing. To evaluate sensing ability of these devices, charged and charged neutral biomolecules are immobilized in nanogap cavity independently. A deep analysis has been performed to show the effect of variation in dielectric constant (k), charge density (ρ), x-composition of Ge, % volume filling of tcavity, length and thickness of a n+-pocket and sensitivity of electrical parameters is also incorporated. Dual-pocket (front and back gate pocket) VB is studied and compared with the LB and VB in the tabular form. Noise characteristic of dielectrically modulated field-effect transistor, L-DMTFET, and V-DMTFET is also evaluated.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The GAA-NS structure has several stacked channels, so it can effectively improve the on-state current and output characteristics of the MOSFET without increasing footprint [30], [31].”
From A Vertically Stacked Nanosheet Gate-All-Around FET for Biosensing Application (2021) · cites this paper as [31]
Citations
Cites
Design of Analog CMOS Integrated Circuits
Razavi, B. (1999) · Cited by 6,609
Double-Gate Tunnel FET With High- Gate Dielectric
Boucart, K., & Ionescu, A. M. (2007) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2007.899389 · Cited by 1,659
Electrical nanogap devices for biosensing
Chen, X., Guo, Z., Yang, G.-M., Li, J., Li, M.-Q., Liu, J.-H., & Huang, X.-J. (2010) · Materials Today · doi:10.1016/s1369-7021(10)70201-7 · Cited by 326
Narang, R., Reddy, K. V. S., Saxena, M., Gupta, R. S., & Gupta, M. (2012) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2012.2208115 · Cited by 308 · cited 2×
“The process steps to design nanogap cavity in gate oxide for L- and V-DMTFETs are described in [11].”
BackgroundMethodComparative analysis of dielectric- modulated FET and TFET-based biosensor
Narang, R., Saxena, M., & Gupta, M. (2015) · IEEE Transactions on Nanotechnology · doi:10.1109/tnano.2015.2396899 · Cited by 296
Proposal for tunnel-field-effect-transistor as ultra-sensitive and label-free biosensors
Sarkar, D., & Banerjee, K. (2012) · Applied Physics Letters · doi:10.1063/1.3698093 · Cited by 295
Kanungo, S., Chattopadhyay, S., Gupta, P. S., & Rahaman, H. (2015) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2015.2390774 · Cited by 248
Kanungo, S., Chattopadhyay, S., Gupta, P. S., Sinha, K., & Rahaman, H. (2016) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2016.2556081 · Cited by 243
A Charge-Plasma-Based Dielectric-Modulated Junctionless TFET for Biosensor Label-Free Detection
Singh, D., Pandey, S., Nigam, K., Sharma, D., Yadav, D. S., & Kondekar, P. (2017) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2016.2622403 · Cited by 237
Self-citationModeling of High-Performance p-Type III–V Heterojunction Tunnel FETs
Knoch, J., & Appenzeller, J. (2010) · IEEE Electron Device Letters · doi:10.1109/led.2010.2041180 · Cited by 224
A charge-modulated FET for detection of biomolecular processes: conception, modeling, and simulation
Barbaro, M., Bonfiglio, A., & Raffo, L. (2006) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2005.860659 · Cited by 196
Ghosh, P., Haldar, S., Gupta, R. S., & Gupta, M. (2012) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2012.2219537 · Cited by 179
Wang, L., Yu, E. T., Taur, Y., & Asbeck, P. M. (2010) · IEEE Electron Device Letters · doi:10.1109/led.2010.2044012 · Cited by 139
Vertical Tunnel FET: Design Optimization With Triple Metal-Gate Layers
Ko, E., Lee, H., Park, J., & Shin, C. (2016) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2016.2619372 · Cited by 121
Dielectric modulated overlapping gate-on-drain tunnel-FET as a label-free biosensor
Abdi, D. B., & Kumar, M. J. (2015) · Superlattices and Microstructures · doi:10.1016/j.spmi.2015.07.052 · Cited by 118
Fundamental limitations of conventional-FET biosensors: Quantum-mechanical-tunneling to the rescue
Sarkar, D., & Banerjee, K. (2012) · Conference digest · doi:10.1109/drc.2012.6256950 · Cited by 117
Sarkar, D., Goßner, H., Hänsch, W., & Banerjee, K. (2013) · Applied Physics Letters · doi:10.1063/1.4775358 · Cited by 109
Ganapathi, K., Yoon, Y., & Salahuddin, S. (2010) · Applied Physics Letters · doi:10.1063/1.3466908 · Cited by 96
Ganapathi, K., & Salahuddin, S. (2011) · IEEE Electron Device Letters · doi:10.1109/led.2011.2112753 · Cited by 95
Line and Point Tunneling in Scaled Si/SiGe Heterostructure TFETs
Schmidt, M., Schäfer, A., Minamisawa, R. A., Buca, D., Trellenkamp, S., Hartmann, J., Zhao, Q., & Mantl, S. (2014) · IEEE Electron Device Letters · doi:10.1109/led.2014.2320273 · Cited by 83
Biosensor Systems in Standard CMOS Processes: Fact or Fiction?
Jang, B., & Hassibi, A. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2011450 · Cited by 83
Study of Random Variation in Germanium-Source Vertical Tunnel FET
Lee, H., Park, J., & Shin, C. (2016) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2016.2539209 · Cited by 60
Verma, M., Sharma, D., Pandey, S. K., Nigam, K., & Kondekar, P. N. (2016) · Superlattices and Microstructures · doi:10.1016/j.spmi.2016.11.045 · Cited by 56
Self-citationLow-power tunnel field effect transistors using mixed As and Sb based heterostructures
Zhu, Y., & Hudait, M. K. (2013) · Nanotechnology Reviews · doi:10.1515/ntrev-2012-0082 · Cited by 55
Threshold voltage in tunnel FETs: physical definition, extraction, scaling and impact on IC design
Boucart, K., & Ionescu, A. M. (2007) · European Solid-State Device Research Conference · doi:10.1109/essderc.2007.4430937 · Cited by 48
Khaveh, H. R. T., & Mohammadi, S. (2016) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2016.2619761 · Cited by 38
Investigation of Size Dependence on Sensitivity for Nanowire FET Biosensors
Ahn, J., Choi, S., Han, J., Park, T. J., Lee, S. Y., & Choi, Y. (2011) · IEEE Transactions on Nanotechnology · doi:10.1109/tnano.2011.2157519 · Cited by 32
Analysis of GaSb-InAs Gate all around (GAA) p-i-n tunnel FET (TFET) for application as a bio-sensor
Ajay, Gupta, M., Narang, R., & Saxena, M. K. (2016) · IEEE International Nanoelectronics Conference · doi:10.1109/inec.2016.7589324 · Cited by 26
Kanungo, S., Gupta, P. S., & Rhaman, H. (2014) · International Conference on Devices, Circuits and Systems (ICDCS) · doi:10.1109/icdcsyst.2014.6926218 · Cited by 12
Electrostatic design of vertical tunneling field-effect transistors
Teherani, J. T., Yu, T., Antoniadis, D. A., & Hoyt, J. L. (2013) · Berkeley Symposium on Energy Efficient Electronic Systems (E3S) · doi:10.1109/e3s.2013.6705872 · Cited by 10
Carrillo-Nuñez, H., Luisier, M., & Schenk, A. (2016) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2016.2620155 · Cited by 9
Research works printed but not linked: 1
- 2016, ATLAS Device Simulation Software Version 5 19 20
Cited by
Goswami, R., & Bhowmick, B. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2928182 · Cited by 248
Wangkheirakpam, V. D., Bhowmick, B., & Pukhrambam, P. D. (2020) · IEEE Transactions on Nanotechnology · doi:10.1109/tnano.2020.2969206 · Cited by 199
Bhattacharyya, A., Chanda, M., & De, D. (2019) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2019.2928850 · Cited by 155
Simulation Study of Dielectric Modulated Dual Channel Trench Gate TFET-Based Biosensor
Kumar, S., Singh, Y., Singh, B., & Tiwari, P. K. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3001300 · Cited by 130
Reddy, N. N., & Panda, D. K. (2020) · Silicon · doi:10.1007/s12633-020-00657-1 · Cited by 127
Metadata
- Authors
- Verma, M., Tirkey, S., Yadav, S., Sharma, D., & Yadav, D. S.
- Affiliations
- Indian Institute of Information Technology Design and Manufacturing Jabalpur (IN)
- Venue
- IEEE Transactions on Electron Devices
- Published
- 2017-09
- Volume
- 64
- Issue
- 9
- Pages
- 3841-3848
- ISSN
- 0018-9383 (ISSN-L)
- 1557-9646
- OpenAlex
- W2742579214
- Semantic Scholar
- 7d5dfaf97f2632e85b35b04c9737709f87cd47ab
- Cited by
- 276
- References
- 31
- Citations by year
- 2026: 36 · 2025: 51 · 2024: 62 · 2023: 37 · 2022: 39 · 2021: 22 · 2020: 17 · 2019: 7 · 2018: 5
- FWCI
- 3.30
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Electron Devices (publishedVersion)
- Funders
- Department of Science and Technology, Ministry of Science and Technology, India
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advancements in Semiconductor Devices and Circuit Design
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Keywords
- tunnel field-effect transistor, dielectric modulation, label-free biosensor, underlap, vertical tunneling, subthreshold swing, nanogap cavity, biomolecule immobilization, noise characteristics, dielectric constant, charge density
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.