Fuel Consumption Minimization of a Microgrid
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A cost optimization scheme for a microgrid is presented. Prior to the optimization of the microgrid itself, several schemes for sharing power between two generators are compared. The minimization of fuel use in a microgrid with a variety of power sources is then discussed. The optimization of a small power system has important differences from the case of a large system and its traditional economic dispatch problem. Among the most important differences is the presence of a local heat demand which adds another dimension to the optimization problem. The microgrid considered in this paper consists of two reciprocating gas engines, a combined heat and power plant, a photovoltaic array and a wind generator. The optimization is aimed at reducing the fuel consumption rate of the system while constraining it to fulfil the local energy demand (both electrical and thermal) and provide a certain minimum reserve power. A penalty is applied for any heat produced in excess of demand. The solution of the optimization problem strongly supports the idea of having a communication infrastructure operating between the power sources.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lasseter, R. H. (2003) · 2002 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.02CH37309) · doi:10.1109/pesw.2002.985003 · Cited by 1,997
Weedy, B. M. (1972) · Cited by 724
Cited by
Olivares, D. E., Mehrizi-Sani, A., Etemadi, A. H., Canizares, C. A., Iravani, R., Kazerani, M., Hajimiragha, A. H., Gomis-Bellmunt, O., Saeedifard, M., Palma-Behnke, R., et al. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2295514 · Cited by 3,137
“In the approach presented in [2], all possible operation states are analysed offline and the optimal dispatch of the system for each scenario is calculated and stored in a look-up table to be accessed in real-time operation.”
BackgroundMethodModeling, Analysis and Testing of Autonomous Operation of an Inverter-Based Microgrid
Pogaku, N., Prodanovic, M., & Green, T. C. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.890003 · Cited by 3,018
Self-citationHierarchical Structure of Microgrids Control System
Bidram, A., & Davoudi, A. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2197425 · Cited by 1,515
State of the Art in Research on Microgrids: A Review
Parhizi, S., Lotfi, H., Khodaei, A., & Bahramirad, S. (2015) · IEEE Access · doi:10.1109/access.2015.2443119 · Cited by 1,194
Energy Management in Autonomous Microgrid Using Stability-Constrained Droop Control of Inverters
Barklund, E., Pogaku, N., Prodanovic, M., Hernandez-Aramburo, C., & Green, T. C. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2001910 · Cited by 733
Self-citationDemand response in smart electricity grids equipped with renewable energy sources: A review
Aghaei, J., & Alizadeh, M.-I. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.09.019 · Cited by 689
Multiobjective Intelligent Energy Management for a Microgrid
Chaouachi, A., Kamel, R. M., Andoulsi, R., & Nagasaka, K. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2188873 · Cited by 657
Moghaddam, A. A., Seifi, A., Niknam, T., & Alizadeh Pahlavani, M. R. (2011) · Energy · doi:10.1016/j.energy.2011.09.017 · Cited by 630
AC and DC technology in microgrids: A review
Planas, E., Andreu, J., Gárate, J. I., Martínez de Alegría, I., & Ibarra, E. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.11.067 · Cited by 500
Zhao, B., Zhang, X., Chen, J., Wang, C., & Guo, L. (2013) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2013.2248400 · Cited by 477
Schiffer, J., Seel, T., Raisch, J., & Sezi, T. (2016) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2015.2420622 · Cited by 450
Paradigm shift in urban energy systems through distributed generation: Methods and models
Manfren, M., Caputo, P., & Costa, G. (2011) · Applied Energy · doi:10.1016/j.apenergy.2010.10.018 · Cited by 437
Conditions for stability of droop-controlled inverter-based microgrids
Schiffer, J., Ortega, R., Astolfi, A., Raisch, J., & Sezi, T. (2014) · Automatica · doi:10.1016/j.automatica.2014.08.009 · Cited by 434
Smart operations of smart grids integrated with distributed generation: A review
Kakran, S., & Chanana, S. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.07.045 · Cited by 427
Recent developments in microgrids and example cases around the world—A review
Ustun, T. S., Ozansoy, C., & Zayegh, A. (2011) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2011.07.033 · Cited by 415
Microgrid supervisory controllers and energy management systems: A literature review
Meng, L., Sanseverino, E. R., Luna, A., Dragicevic, T., Vasquez, J. C., & Guerrero, J. M. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.03.003 · Cited by 415
Li, Y., Yang, Z., Li, G., Zhao, D., & Tian, W. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2840498 · Cited by 414
Integrated scheduling of renewable generation and demand response programs in a microgrid
Mazidi, M., Zakariazadeh, A., Jadid, S., & Siano, P. (2014) · Energy Conversion and Management · doi:10.1016/j.enconman.2014.06.078 · Cited by 404
Niknam, T., Azizipanah-Abarghooee, R., & Narimani, M. R. (2012) · Applied Energy · doi:10.1016/j.apenergy.2012.04.017 · Cited by 399
Optimal Power Dispatch of Multi-Microgrids at Future Smart Distribution Grids
Nikmehr, N., & Najafi Ravadanegh, S. (2015) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2396992 · Cited by 377
Computational optimization techniques applied to microgrids planning: A review
Gamarra, C., & Guerrero, J. M. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.04.025 · Cited by 373
Abdelaziz, M. M. A., Farag, H. E., El-Saadany, E. F., & Mohamed, Y. A.-R. I. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2012.2195785 · Cited by 335
Synthesizing Virtual Oscillators to Control Islanded Inverters
Johnson, B. B., Sinha, M., Ainsworth, N. G., Dorfler, F., & Dhople, S. V. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2497217 · Cited by 334
“Particularly, there exists a wide body of the literature that attempts to identify droopcontrol parameters that ensure inverters satisfy steady-state performance metrics and constraints such as voltage regulation, maximum frequency deviation, and proportional power sharing [16]–[20].”
BackgroundA method for optimal sizing energy storage systems for microgrids
Fossati, J. P., Galarza, A., Martín-Villate, A., & Fontán, L. (2015) · Renewable Energy · doi:10.1016/j.renene.2014.12.039 · Cited by 308
Kwasinski, A. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2102774 · Cited by 288
Li, Y., Wang, R., & Yang, Z. (2022) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2021.3105529 · Cited by 269
Niknam, T., Golestaneh, F., & Malekpour, A. (2012) · Energy · doi:10.1016/j.energy.2012.03.064 · Cited by 260
Microgrids: Energy management by strategic deployment of DERs—A comprehensive survey
Basu, A. K., Chowdhury, S. P., Chowdhury, S., & Paul, S. (2011) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2011.07.116 · Cited by 181
Robust Energy Management System for a Microgrid Based on a Fuzzy Prediction Interval Model
Valencia, F., Collado, J., Saez, D., & Marin, L. G. (2016) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2463079 · Cited by 175
“In REMS formulations, two frameworks have been widely used: 1) scenario-based [15], [16]; and 2) stochastic-based”
Method
Metadata
- Authors
- Hernandez-Aramburo, C. A., Green, T. C., & Mugniot, N.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2005-05
- Volume
- 41
- Issue
- 3
- Pages
- 673-681
- ISSN
- 0093-9994 (ISSN-L)
- OpenAlex
- W2145963793
- Cited by
- 526
- References
- 2
- FWCI
- 25.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.