A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
This paper presents a survey on existing methods for fault diagnosis and protection of insulated gate bipolar transistors with special focus on those used in three-phase power inverters. Twenty-one methods for open-circuit faults and ten methods for short-circuit faults are evaluated and summarized, based on their performance and implementation efforts. The gate-misfiring faults and their diagnostic methods are also briefly discussed. Finally, the promising methods are recommended for future work.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These circuits bypass the effect of such fault in very short time without additional computational delay.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [247]
Citations
Cites
Fault detection of open-switch damage in voltage-fed PWM motor drive systems
de Araujo Ribeiro, R. L., Jacobina, C. B., da Silva, E. R. C., & Lima, A. M. N. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.809351 · Cited by 441 · cited 1×
“7) Comparison of AC Voltage Actual and Reference Quantity Approach in Time Domain [1], [ 7 ]: This method uses techniques that require the measurement of the voltages and are based on the analytical model of the VSI.”
MethodInvestigation of fault modes of voltage-fed inverter system for induction motor drive
Kastha, D., & Bose, B. K. (1994) · IEEE Transactions on Industry Applications · doi:10.1109/28.297920 · Cited by 386
Fault detection and isolation on a PWM inverter by knowledge-based model
Peuget, R., Courtine, S., & Rognon, J.-P. (1998) · IEEE Transactions on Industry Applications · doi:10.1109/28.739017 · Cited by 384
Investigation of fault modes of voltage-fed inverter system for induction motor drive
Kastha, D., & Bose, B. K. (2003) · Conference Record of the 1992 IEEE Industry Applications Society Annual Meeting · doi:10.1109/ias.1992.244307 · Cited by 370
Zidani, F., Diallo, D., Benbouzid, M. E. H., & Nait-Said, R. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.911951 · Cited by 335
Fault detection and isolation on a PWM inverter by knowledge-based model
Peuget, R., Courtine, S., & Rognon, J. P. (2002) · IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting · doi:10.1109/ias.1997.629048 · Cited by 304
Fuchs, F. W. (2004) · IECON'03. 29th Annual Conference of the IEEE Industrial Electronics Society (IEEE Cat. No.03CH37468) · doi:10.1109/iecon.2003.1280259 · Cited by 270
Diallo, D., Benbouzid, M. E. H., Hamad, D., & Pierre, X. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847961 · Cited by 220 · cited 2×
“2) Pattern Recognition Approach [ 35 ], [36]: This is a fuzzy-based technique and uses inverter output current to detect the intermittent loss of firing pulses.”
MethodMendes, A. M. S., & Marques Cardoso, A. J. (2003) · IEEE International Electric Machines and Drives Conference. IEMDC'99. Proceedings (Cat. No.99EX272) · doi:10.1109/iemdc.1999.769220 · Cited by 213 · cited 3×
“9) Average Current Park’s Vector Approach [ 3 ]: In this method, the fault occurrence is related to the average current Park’s Vector modulus.”
BackgroundMethodInfluentialRothenhagen, K., & Fuchs, F. W. (2005) · 2005 European Conference on Power Electronics and Applications · doi:10.1109/epe.2005.219426 · Cited by 194
Performance of diagnosis methods for IGBT open circuit faults in voltage source active rectifiers
Rothenhagen, K., & Fuchs, F. W. (2004) · 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551) · doi:10.1109/pesc.2004.1354769 · Cited by 141
Failures-tolerance and remedial strategies of a PWM multicell inverter
Richardeau, F., Baudesson, P., & Meynard, T. A. (2002) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2002.805588 · Cited by 130
Real-time detection of intermittent misfiring in a voltage-fed PWM inverter induction-motor drive
Smith, K. S., Ran, L., & Penman, J. (1997) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.605620 · Cited by 130 · cited 2×
“1) Detection by Output Current Trajectory [ 34 ]: A realtime condition-monitoring algorithm for PWM inverter induction motor drives is discussed in [34].”
BackgroundMethodA New Fault Detection Technique for IGBT Based on Gate Voltage Monitoring
Rodriguez, M. A., Claudio, A., Theilliol, D., & Vela, L. G. (2007) · 2007 IEEE Power Electronics Specialists Conference · doi:10.1109/pesc.2007.4342127 · Cited by 107 · cited 3×
“Very few are algorithm based. A. IGBT Rupture Phenomenon [ 23 ]”
MethodInfluentialIGBT Fault Protection Based on di/dt Feedback Control
Huang, F. H., & Flett, F. (2007) · IEEE Power Electronics Specialists Conference (PESC) · doi:10.1109/pesc.2007.4342213 · Cited by 102 · cited 3×
“2) Current Mirror Method [ 29 ]: The collector current is sensed by a current mirror circuit, which is obtained by integrating a second IGBT into the main IGBT.”
BackgroundMethodInfluentialPower electronics monitoring for a controlled voltage source inverter drive with induction machines
Kral, C., & Kafka, K. (2002) · IEEE Power Electronics Specialists Conference (PESC) · doi:10.1109/pesc.2000.878841 · Cited by 74 · cited 1×
“13) Current Deviation Method [ 13 ]: In this method, normalized value of the inverter output current is used.”
MethodA Novel Fault Detection Scheme for Voltage Fed PWM Inverter
유옥선, Park, N.-J., & Hyun, D.-S. (2006) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2006.347541 · Cited by 72 · cited 1×
“8) Diagnosis by Sensing Voltage Across Lower Switch [ 8 ]:”
MethodExpert systems for fault diagnosis of VSI fed AC drives
Debebe, K., Rajagopalan, V., & Sankar, T. S. (2002) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.1991.178181 · Cited by 67 · cited 1×
“20) Diagnosis by Rule-Based Expert Systems [ 20 ], [21]:”
MethodSwitching voltage transient protection schemes for high-current IGBT modules
Chokhawala, R., & Sobhani, S. (1997) · IEEE Transactions on Industry Applications · doi:10.1109/28.649974 · Cited by 55
Fault Diagnostic in Power System Using Wavelet Transforms and Neural Networks
Charfi, F., Sellami, F., & Al‐Haddad, K. (2006) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie.2006.295798 · Cited by 53 · cited 1×
“15) Wavelet-Neural Network Method [ 15 ]: In this method, the three-phase currents are used for fault detection and classification.”
MethodFault Detection of 3-Phase VSI using Wavelet-Fuzzy Algorithm
Mamat, M. R., Rizon, M., & Khanniche, M. S. (2006) · American Journal of Applied Sciences · doi:10.3844/ajassp.2006.1642.1648 · Cited by 49 · cited 1×
“14) Wavelet-Fuzzy Algorithm [ 14 ]: This is a real-time condition-monitoring algorithm that uses three-phase currents.”
BackgroundC-ANFIS based fault diagnosis for voltage-fed PWM motor drive systems
Park, J.-H., Kim, D., Kim, S.-S., Lee, D.-J., & Chun, M.-G. (2004) · Annual Meeting of the North American Fuzzy Information Processing Society (NAFIPS) · doi:10.1109/nafips.2004.1336312 · Cited by 46 · cited 1×
“17) Clustering-ANFI System [ 17 ]: In this method, the inverter three-phase currents are transformed to d‐q axis first.”
MethodModel-Based Fault Diagnosis in Electric Drive Inverters Using Artificial Neural Network
Masrur, M. A., Chen, Z., Zhang, B., & Murphey, Y. L. (2007) · IEEE Power Engineering Society General Meeting · doi:10.1109/pes.2007.385655 · Cited by 45 · cited 1×
“19) Model-Based ANN Diagnostic Method [ 19 ]: In this method, model of a closed-loop motor drive is developed.”
MethodA New Centroid Based Fault Detection Method for 3-Phase Inverter-Fed Induction Motors
Gilreath, P., & Singh, B. N. (2006) · IEEE Power Electronics Specialists Conference (PESC) · doi:10.1109/pesc.2005.1582009 · Cited by 40 · cited 1×
“9) Centroid-Based Fault Detection [ 9 ]: In this method, fault location and type are identified by determination of the centroid.”
MethodGuan, Y., Sun, D., & He, Y. (2007) · IEEE International Electric Machines & Drives Conference (IEMDC) · doi:10.1109/iemdc.2007.383586 · Cited by 38 · cited 1×
“Method [ 18 ]: This method is based on subtractive clustering analysis of the stator mean current vector.”
MethodShort circuit analysis and protection of power module IGBTs
Pagano, R., Chen, Y., Smedley, K. M., Musumeci, S., & Raciti, A. (2005) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2005.1453063 · Cited by 37 · cited 1×
“4) Over Current [ 27 ], [28]: Over current due to faultunder-load or switching into short circuit (or hard switching fault) causes high collector currents and device failure eventually.”
BackgroundIGBT behavior during desat detection and short circuit fault protection
Bhalla, A., Shekhawat, S., Gladish, J., Yedinak, J., & Dolny, G. (2002) · Proceedings of the 10th International Symposium on Power Semiconductor Devices and ICs. ISPSD'98 (IEEE Cat. No.98CH36212) · doi:10.1109/ispsd.1998.702679 · Cited by 36 · cited 1×
“8) Protection by Two-Step Gate Pulse [ 32 ]: In hard switched fault, the device current ramps up very rapidly until it saturates, forcing the IGBT voltage to rise to the dc clamp.”
MethodA novel protection technique devoted to the improvement of the short circuit ruggedness of IGBTs
Musumeci, S., Pagano, R., Raciti, A., Belverde, G., Guastella, C., & Melito, M. (2004) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2003.1280319 · Cited by 26 · cited 2×
“5) Protection by Gate Voltage Limiting [ 30 ]: These are peak current limiting circuits that are developed to protect IGBTs against fault-under-load conditions.”
BackgroundA new type short circuit failures of high power IGBT's
Cassel, R., & Nguyen, M. N. (2002) · doi:10.1109/ppps.2001.1002057 · Cited by 24 · cited 1×
“2) Impact Ionization [24], [25]: Impact ionization and current crowding cause excess heat generation and eventually lead to device breakdown [ 26 ].”
BackgroundModelling, Simulation and Fault Diagnosis of the Three-Phase Inverter Using Bond Graph
Contreras, B. M. G., Rullan-Lara, J. L., Vela-Valdés, L. G., & Claudio, A. (2007) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie.2007.4374586 · Cited by 24 · cited 1×
“21) Using Bond Graph Model [ 22 ]: In this method, the inverter system along with IGBT is modeled using Bond Graph methodology.”
MethodDiagnosis of switch open-circuit fault in PM brushless DC motor drives
Awadallah, M. A., & Morcos, M. M. (2003) · Large Engineering Systems Conference on Power Engineering · doi:10.1109/lescpe.2003.1204682 · Cited by 23 · cited 1×
“16) Wavelet-ANFI System [ 16 ]: In this method, the drive dc-link current is monitored over one cycle for diagnosis.”
MethodDiagnosis and monitoring for AC drives
Debebe, K., Rajagopalan, V., & Sankar, T. S. (2003) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.1992.244371 · Cited by 22 · cited 1×
“20) Diagnosis by Rule-Based Expert Systems [20], [ 21 ]:”
MethodInternal dynamics of IGBT during short circuit switching
Trivedi, M., & Shenai, K. (2002) · IEEE Bipolar/BiCMOS Circuits and Technology Meeting (BCTM) · doi:10.1109/bipol.1996.554144 · Cited by 14 · cited 1×
“2) Impact Ionization [ 24 ], [25]: Impact ionization and current crowding cause excess heat generation and eventually lead to device breakdown [26].”
BackgroundEvolution in IGBT's protection against short circuit behaviors by gate-side circuitry
Pagano, R., & Raciti, A. (2002) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie.2002.1025855 · Cited by 11 · cited 1×
“4) Over Current [27], [ 28 ]: Over current due to faultunder-load or switching into short circuit (or hard switching fault) causes high collector currents and device failure eventually.”
BackgroundFailure mode of different irradiated power IGBT structures
Lorfèvre, E., Dachs, E., Detcheverry, C., Sudre, C., Roubaud, F., Palau, J. M., Gasiot, J., Calvet, M.-C., & Ecoffets, R. (2002) · European Conference on Radiation and Its Effects on Components and Systems · doi:10.1109/radecs.1997.698988 · Cited by 9 · cited 1×
“2) Impact Ionization [24], [ 25 ]: Impact ionization and current crowding cause excess heat generation and eventually lead to device breakdown [26].”
Background
Research works printed but not linked: 3
- zhang, 1995, a knowledge-based system for on-line fault diagnosis of power inverter circuits for ac machines, Proc Eur Power Electron Conf, 334
- szczesny, 1997, fault detection and diagnosis in the electric drives, Proc Eur Power Electron Appl Conf, 995
- raison, 2000, towards a global monitoring scheme for induction motor drives, Proc Int Power Electron Conf, 1183
Cited by
Short-Circuit and Ground Fault Analyses and Location in VSC-Based DC Network Cables
Yang, J., Fletcher, J. E., & O'Reilly, J. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2162712 · Cited by 790
Study and Handling Methods of Power IGBT Module Failures in Power Electronic Converter Systems
Choi, U.-M., Blaabjerg, F., & Lee, K.-B. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2373390 · Cited by 700
Transitioning to Physics-of-Failure as a Reliability Driver in Power Electronics
Wang, H., Liserre, M., Blaabjerg, F., de Place Rimmen, P., Jacobsen, J. B., Kvisgaard, T., & Landkildehus, J. (2014) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2290282 · Cited by 693
Offshore wind turbine operations and maintenance: A state-of-the-art review
Ren, Z., Verma, A. S., Li, Y., Teuwen, J. J. E., & Jiang, Z. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2021.110886 · Cited by 685
Oh, H., Han, B., McCluskey, P., Han, C., & Youn, B. D. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2346485 · Cited by 513
Metadata
- Authors
- Lu, B., & Sharma, S. K.
- Affiliations
- Papal Seminary (IN)
- ORCID
- Sharma, S.K.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2009
- Volume
- 45
- Issue
- 5
- Pages
- 1770-1777
- ISSN
- 0093-9994 (ISSN-L)
- 1939-9367
- OpenAlex
- W2142351866
- Cited by
- 985
- References
- 35
- Citations by year
- 2026: 29 · 2025: 54 · 2024: 66 · 2023: 74 · 2022: 77 · 2021: 86 · 2020: 88 · 2019: 80 · 2018: 64 · 2017: 59 · 2016: 72 · 2015: 67 · 2014: 50 · 2013: 50 · 2012: 29
- FWCI
- 17.98
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Industry Applications (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Silicon Carbide Semiconductor Technologies
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Control and Systems Engineering › Power Systems Fault Detection
- Keywords
- IGBT, fault diagnosis, fault protection, inverter, three-phase inverter, open-circuit fault, short-circuit faults, power semiconductor devices
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.