The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Analysis, Design, and Implementation of Virtual Impedance for Power Electronics Interfaced Distributed Generation
Abstract
This paper presents a virtual impedance design and implementation approach for power electronics interfaced distributed generation (DG) units. To improve system stability and prevent power couplings, the virtual impedances can be placed between interfacing converter outputs and the main grid. However, optimal design of the impedance value, robust implementation of the virtual impedance, and proper utilization of the virtual impedance for DG performance enhancement are key for the virtual impedance concept. In this paper, flexible small-signal models of microgrids in different operation modes are developed first. Based on the developed microgrid models, the desired DG impedance range is determined considering the stability, transient response, and power flow performance of DG units. A robust virtual impedance implementation method is also presented, which can alleviate voltage distortion problems caused by harmonic loads compared to the effects of physical impedances. Furthermore, an adaptive impedance concept is proposed to further improve power control performances during the transient and grid faults. Simulation and experimental results are provided to validate the impedance design approach, the virtual impedance implementation method, and the proposed adaptive transient impedance control strategies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075
Power-Electronic Systems for the Grid Integration of Renewable Energy Sources: A Survey
Carrasco, J. M., Franquelo, L. G., Bialasiewicz, J. T., Galvan, E., PortilloGuisado, R. C., Prats, M. A. M., Leon, J. I., & Moreno-Alfonso, N. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.878356 · Cited by 4,018
Modeling, Analysis and Testing of Autonomous Operation of an Inverter-Based Microgrid
Pogaku, N., Prodanovic, M., & Green, T. C. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.890003 · Cited by 3,018
Power electronics as efficient interface in dispersed power generation systems
Blaabjerg, F., Chen, Z., & Kjaer, S. B. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833453 · Cited by 2,588
Design and Control of an LCL-Filter-Based Three-Phase Active Rectifier
Liserre, M., Blaabjerg, F., & Hansen, S. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2005.853373 · Cited by 2,402
Lasseter, R. H. (2003) · 2002 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.02CH37309) · doi:10.1109/pesw.2002.985003 · Cited by 1,997
A Voltage and Frequency Droop Control Method for Parallel Inverters
De Brabandere, K., Bolsens, B., Van den Keybus, J., Woyte, A., Driesen, J., & Belmans, R. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.900456 · Cited by 1,865
Power Management Strategies for a Microgrid With Multiple Distributed Generation Units
Katiraei, F., & Iravani, M. R. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2006.879260 · Cited by 1,578
Stationary frame current regulation of PWM inverters with zero steady-state error
Zmood, D. N., & Holmes, D. G. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.810852 · Cited by 1,518
Mohamed, Y., & El-Saadany, E. F. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2005100 · Cited by 1,230
Output Impedance Design of Parallel-Connected UPS Inverters With Wireless Load-Sharing Control
Guerrero, J. M., GarciadeVicuna, L., Matas, J., Castilla, M., & Miret, J. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.851634 · Cited by 1,221
Li, Y. W., & Kao, C.-N. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2022828 · Cited by 1,127
Self-citationGuerrero, J. M., GarciadeVicuna, L., Matas, J., Castilla, M., & Miret, J. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833451 · Cited by 1,039
Control Strategy for Flexible Microgrid Based on Parallel Line-Interactive UPS Systems
Guerrero, J. M., Vasquez, J. C., Matas, J., Castilla, M., & de Vicuna, L. G. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2009274 · Cited by 788
Design, Analysis, and Real-Time Testing of a Controller for Multibus Microgrid System
Li, Y., Vilathgamuwa, D. M., & Loh, P. C. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833456 · Cited by 723
Self-citationControl of Distributed Uninterruptible Power Supply Systems
Guerrero, J. M., Hang, L., & Uceda, J. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.924173 · Cited by 700
Small-signal stability for parallel-connected inverters in stand-alone AC supply systems
Coelho, E. A. A., Cortizo, P. C., & Garcia, P. F. D. (2002) · IEEE Transactions on Industry Applications · doi:10.1109/28.993176 · Cited by 662
Li, Y., & Li, Y. W. (2011) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2010.2095046 · Cited by 366
Self-citationVoltage Support Provided by a Droop-Controlled Multifunctional Inverter
Vasquez, J. C., Mastromauro, R. A., Guerrero, J. M., & Liserre, M. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2015357 · Cited by 326
Decentralized Parallel Operation of Inverters Sharing Unbalanced and Nonlinear Loads
De, D., & Ramanarayanan, V. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2068313 · Cited by 276
A Cooperative Imbalance Compensation Method for Distributed-Generation Interface Converters
Cheng, P.-T., Chen, C.-A., Lee, T.-L., & Kuo, S.-Y. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2013601 · Cited by 253
Line-Interactive UPS Using a Fuel Cell as the Primary Source
Tao, H., Duarte, J. L., & Hendrix, M. A. M. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.918472 · Cited by 227
Cited by
Grid-Forming Converters: Control Approaches, Grid-Synchronization, and Future Trends—A Review
Rosso, R., Wang, X., Liserre, M., Lu, X., & Engelken, S. (2021) · IEEE Open Journal of Industry Applications · doi:10.1109/ojia.2021.3074028 · Cited by 1,187
Review of Power Sharing Control Strategies for Islanding Operation of AC Microgrids
Han, H., Hou, X., Yang, J., Wu, J., Su, M., & Guerrero, J. M. (2016) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2434849 · Cited by 988
Distributed Cooperative Control of DC Microgrids
Nasirian, V., Moayedi, S., Davoudi, A., & Lewis, F. L. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2324579 · Cited by 971
Emerging Power Quality Challenges Due to Integration of Renewable Energy Sources
Liang, X. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2626253 · Cited by 935
D’Arco, S., Suul, J. A., & Fosso, O. B. (2015) · Electric Power Systems Research · doi:10.1016/j.epsr.2015.01.001 · Cited by 704
Metadata
- Authors
- He, J., & Li, Y. W.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2011-11
- Volume
- 47
- Issue
- 6
- Pages
- 2525-2538
- ISSN
- 0093-9994 (ISSN-L)
- OpenAlex
- W2024559217
- Cited by
- 759
- References
- 22
- FWCI
- 41.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.