The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
A New Approach for Real-Time Multiple Open-Circuit Fault Diagnosis in Voltage-Source Inverters
Abstract
Practically all the diagnostic methods for opencircuit faults in voltage-source inverters (VSI) developed during the last decades are focused on the occurrence of single faults and do not have the capability to handle and identify multiple failures. This paper presents a new method for real-time diagnostics of multiple open-circuit faults in VSI feeding ac machines. In contrast with the majority of the methods found in the literature which are based on the motor phase currents average values, the average absolute values are used here as principal quantities to formulate the diagnostic variables. These prove to be more robust against the issue of false alarms, carrying also information about multiple open-circuit failures. Furthermore, by the combination of these variables with the machine phase currents average values, it is possible to obtain characteristic signatures, which allow for the detection and identification of single and multiple open-circuit faults.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Industry-Based Survey of Reliability in Power Electronic Converters
Yang, S., Bryant, A., Mawby, P., Xiang, D., Ran, L., & Tavner, P. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2124436 · Cited by 2,019
Condition Monitoring for Device Reliability in Power Electronic Converters: A Review
Yang, S., Xiang, D., Bryant, A., Mawby, P., Ran, L., & Tavner, P. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2049377 · Cited by 1,278 · cited 1×
“Another study shows that semiconductor, soldering, and printed circuit board failures in device modules total 60% of converter system failures [ 3 ].”
BackgroundA Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters
Lu, B., & Sharma, S. K. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2027535 · Cited by 985
Fault detection of open-switch damage in voltage-fed PWM motor drive systems
de Araujo Ribeiro, R. L., Jacobina, C. B., da Silva, E. R. C., & Lima, A. M. N. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.809351 · Cited by 441
Fault detection and isolation on a PWM inverter by knowledge-based model
Peuget, R., Courtine, S., & Rognon, J.-P. (1998) · IEEE Transactions on Industry Applications · doi:10.1109/28.739017 · Cited by 384
Zidani, F., Diallo, D., Benbouzid, M. E. H., & Nait-Said, R. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.911951 · Cited by 335
Fault detection and isolation on a PWM inverter by knowledge-based model
Peuget, R., Courtine, S., & Rognon, J. P. (2002) · IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting · doi:10.1109/ias.1997.629048 · Cited by 304
Open-Transistor Fault Diagnostics in Voltage-Source Inverters by Analyzing the Load Currents
Sleszynski, W., Nieznanski, J., & Cichowski, A. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2023640 · Cited by 300
Fuchs, F. W. (2004) · IECON'03. 29th Annual Conference of the IEEE Industrial Electronics Society (IEEE Cat. No.03CH37468) · doi:10.1109/iecon.2003.1280259 · Cited by 270
A Failure-Detection Strategy for IGBT Based on Gate-Voltage Behavior Applied to a Motor Drive System
Rodríguez-Blanco, M. A., Claudio-Sánchez, A., Theilliol, D., Vela-Valdés, L. G., Sibaja-Terán, P., Hernández-González, L., & Aguayo-Alquicira, J. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2098355 · Cited by 264
An, Q.-T., Sun, L.-Z., Zhao, K., & Sun, L. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2052472 · Cited by 262
Campos-Delgado, D. U., & Espinoza-Trejo, D. R. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2047829 · Cited by 224
Mendes, A. M. S., & Marques Cardoso, A. J. (2003) · IEEE International Electric Machines and Drives Conference. IEMDC'99. Proceedings (Cat. No.99EX272) · doi:10.1109/iemdc.1999.769220 · Cited by 213
Self-citationRothenhagen, K., & Fuchs, F. W. (2005) · 2005 European Conference on Power Electronics and Applications · doi:10.1109/epe.2005.219426 · Cited by 194
Voltage source inverter fault diagnosis in variable speed AC drives, by Park's vector approach
Mendes, A. M. S. (1998) · International Conference on Power Electronics and Variable Speed Drives (PEVD) · doi:10.1049/cp:19980607 · Cited by 102
Simple Fault Diagnosis Based on Operating Characteristic of Brushless Direct-Current Motor Drives
Park, B.-G., Lee, K., Kim, R.-Y., Kim, T., Ryu, J.-S., & Hyun, D.-S. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2072895 · Cited by 99
Trabelsi, M., Boussak, M., & Gossa, M. (2010) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2010.5608044 · Cited by 96
Power electronics monitoring for a controlled voltage source inverter drive with induction machines
Kral, C., & Kafka, K. (2002) · IEEE Power Electronics Specialists Conference (PESC) · doi:10.1109/pesc.2000.878841 · Cited by 74
Sethom, H. B. A., & Ghedamsi, M. A. (2008) · DOAJ (DOAJ: Directory of Open Access Journals) · Cited by 37
Estima, J. O., & Cardoso, A. J. M. (2010) · International Symposium on Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM) · doi:10.1109/speedam.2010.5545024 · Cited by 25
Self-citationEstima, J. O., & Cardoso, A. J. M. (2011) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2011.6063649 · Cited by 21
Self-citation
Cited by
Trends in Fault Diagnosis for Electrical Machines: A Review of Diagnostic Techniques
Henao, H., Capolino, G.-A., Fernandez-Cabanas, M., Filippetti, F., Bruzzese, C., Strangas, E., Pusca, R., Estima, J., Riera-Guasp, M., & Hedayati-Kia, S. (2014) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2013.2287651 · Cited by 602
Self-citationRiera-Guasp, M., Antonino-Daviu, J. A., & Capolino, G.-A. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2375853 · Cited by 573
Estima, J. O., & Marques Cardoso, A. J. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2188877 · Cited by 377
“New algorithms with multiple faults diagnosis were proposed in [23]-[24].”
BackgroundSelf-citationLi, B., Shi, S., Wang, B., Wang, G., Wang, W., & Xu, D. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2454534 · Cited by 329
Ji, B., Pickert, V., Cao, W., & Zahawi, B. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2251358 · Cited by 329
Metadata
- Authors
- Estima, J. O., & Marques Cardoso, A. J.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2011-11
- Volume
- 47
- Issue
- 6
- Pages
- 2487-2494
- ISSN
- 0093-9994 (ISSN-L)
- OpenAlex
- W1966336208
- Cited by
- 298
- References
- 21
- FWCI
- 27.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.