Abstract
Renewable energy sources such as wind turbine and photovoltaic power generators may make the power grid unstable due to their output fluctuations. Battery energy storage systems (BESSs) are being considered as a countermeasure for this issue. A modular multilevel cascade converter (MMCC) is expected as a power conversion circuit for BESSs because each bridge cell can control the state of charge of a battery unit, independent of that of another one, and the harmonic current generated is low enough to eliminate the ac filter, normally installed on conventional two-level converters, from the MMCC. This paper describes the development of a real-scale (500 kW) single-star-bridge-cell-based MMCC for BESSs and reports successful test results obtained from a downscaled grid model and a 6.6-kV real-scale distribution line.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Multilevel Converters: Fundamental Circuits and Systems
Akagi, H. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2017.2682105 · Cited by 513
Self-citationA Review of Power Electronics for Grid Connection of Utility-Scale Battery Energy Storage Systems
Wang, G., Konstantinou, G., Townsend, C. D., Pou, J., Vazquez, S., Demetriades, G. D., & Agelidis, V. G. (2016) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2016.2586941 · Cited by 362
Dynamic Energy Management of Renewable Grid Integrated Hybrid Energy Storage System
Tummuru, N. R., Mishra, M. K., & Srinivas, S. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2455063 · Cited by 359
MMC-Based SRM Drives With Decentralized Battery Energy Storage System for Hybrid Electric Vehicles
Gan, C., Sun, Q., Wu, J., Kong, W., Shi, C., & Hu, Y. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2846622 · Cited by 147
“Therefore, each battery pack can be easily connected with a converter for independent control [47], [48].”
BackgroundControl of arm capacitor voltages in modular multilevel converters
Lizana, R., Perez, M. A., Bernet, S., Espinoza, J. R., & Rodriguez, J. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2426183 · Cited by 70
“This situation can take place, for example, when the MMC is used in photovoltaic applications [21]–[23], where the panels are directly connected to each cell and the capacitor voltage must change in order to achieve the maximum power point tracking [24], or in battery energy storage systems [25], [26].”
BackgroundXavier, L. S., Amorim, W. C. S., Cupertino, A. F., Mendes, V. F., do Boaventura, W. C., & Pereira, H. A. (2019) · BMC Energy · doi:10.1186/s42500-019-0006-5 · Cited by 61
Metadata
- Authors
- Kawakami, N., Ota, S., Kon, H., Konno, S., Akagi, H., Kobayashi, H., & Okada, N.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2014-11
- Volume
- 50
- Issue
- 6
- Pages
- 3902-3910
- ISSN
- 0093-9994 (ISSN-L)
- 1939-9367
- OpenAlex
- W2322151017
- Cited by
- 120
- References
- 0
- FWCI
- 3.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.