Reactive Power Injection Strategies for Single-Phase Photovoltaic Systems Considering Grid Requirements
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
As the development and installation of photovoltaic (PV) systems are still growing at an exceptionally rapid pace, relevant grid integration policies are going to change consequently in order to accept more PV systems in the grid. The next-generation PV systems will play an even more active role like what the conventional power plants do today in the grid regulation participation. Requirements of ancillary services like low-voltage ride-through (LVRT) associated with reactive current injection and voltage support through reactive power control have been in effectiveness in some countries, e.g., Germany and Italy. Those advanced features can be provided by next-generation PV systems and will be enhanced in the future to ensure an even efficient and reliable utilization of PV systems. In light of this, reactive power injection (RPI) strategies for single-phase PV systems are explored in this paper. The RPI possibilities are as follows: 1) constant average active power control; 2) constant active current control; 3) constant peak current control; and 4) thermal optimized control strategy. All those strategies comply with the currently active grid codes but are with different objectives. The proposed RPI strategies are demonstrated first by simulations and also tested experimentally on a 1-kW singe-phase grid-connected system in LVRT operation mode. Those results show the effectiveness and feasibilities of the proposed strategies with reactive power control during LVRT operation. The design and implementation considerations for the characterized RPI strategies are also discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Overview of Control and Grid Synchronization for Distributed Power Generation Systems
Blaabjerg, F., Teodorescu, R., Liserre, M., & Timbus, A. V. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.881997 · Cited by 5,220
Self-citationA Review of Single-Phase Grid-Connected Inverters for Photovoltaic Modules
Kjaer, S. B., Pedersen, J. K., & Blaabjerg, F. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2005.853371 · Cited by 3,621
Self-citationGrid Converters for Photovoltaic and Wind Power Systems
Teodorescu, R., Liserre, M., & Rodríguez, P. (2011) · Wiley eBooks · doi:10.1002/9780470667057 · Cited by 3,344
Toward Reliable Power Electronics: Challenges, Design Tools, and Opportunities
Wang, H., Liserre, M., & Blaabjerg, F. (2013) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2013.2252958 · Cited by 916
Self-citation(2008) · Cited by 578
Avenas, Y., Dupont, L., & Khatir, Z. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2178433 · Cited by 559
Improved Low Voltage Grid-Integration of Photovoltaic Systems in Germany
Stetz, T., Marten, F., & Braun, M. (2013) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2012.2198925 · Cited by 466
Grid-Connected Photovoltaic Generation Plants: Components and Operation
Romero-Cadaval, E., Spagnuolo, G., Franquelo, L. G., Ramos-Paja, C. A., Suntio, T., & Xiao, W. M. (2013) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2013.2264540 · Cited by 449
Integration Issues of Distributed Generation in Distribution Grids
Coster, E. J., Myrzik, J. M. A., Kruimer, B., & Kling, W. L. (2011) · Proceedings of the IEEE · doi:10.1109/jproc.2010.2052776 · Cited by 422
A Lifetime Estimation Technique for Voltage Source Inverters
Huang, H., & Mawby, P. A. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2229472 · Cited by 394
Cited by
Grid Integration Challenges and Solution Strategies for Solar PV Systems: A Review
Shafiullah, M., Ahmed, S. D., & Al-Sulaiman, F. A. (2022) · IEEE Access · doi:10.1109/access.2022.3174555 · Cited by 473
Sarkar, M. N. I., Meegahapola, L. G., & Datta, M. (2018) · IEEE Access · doi:10.1109/access.2018.2838563 · Cited by 256
Grid Integration of Small-Scale Photovoltaic Systems in Secondary Distribution Network—A Review
Panigrahi, R., Mishra, S. K., Srivastava, S. C., Srivastava, A. K., & Schulz, N. N. (2020) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2020.2979789 · Cited by 214
“strategies for anti-islanding protection [101]–[117], LVRT [118]–[129], reactive power injection [120], and improving the resiliency of power distribution systems [130]–[139] were also”
BackgroundMethodPower control flexibilities for grid‐connected multi‐functional photovoltaic inverters
Yang, Y., Blaabjerg, F., Wang, H., & Simões, M. G. (2016) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2015.0133 · Cited by 182
“PV inverters) have become of high interest [21], [33], [35], [55], [67].”
BackgroundSelf-citationAnurag, A., Yang, Y., & Blaabjerg, F. (2015) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2015.2428432 · Cited by 153
“The power electronics interface of the PV systems enables an appropriate reactive power exchange with the grid, thus providing reactive power support and keeping the bus voltages within operating limits [16], [17].”
BackgroundSelf-citationA review of control techniques for inverter-based distributed energy resources applications
Hasheminasab, S., Alzayed, M., & Chaoui, H. (2024) · Energies · doi:10.3390/en17122940 · Cited by 56
Ali, A., Mahmoud, K., Raisz, D., & Lehtonen, M. (2021) · IEEE Systems Journal · doi:10.1109/jsyst.2020.2982467 · Cited by 50
IGBT Reliability Analysis of Photovoltaic Inverter with Reactive Power Output Capability
Zhang, B., & Gao, Y. (2023) · Microelectronics Reliability · doi:10.1016/j.microrel.2023.115073 · Cited by 25
Metadata
- Authors
- Yang, Y., Wang, H., & Blaabjerg, F.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2014-11
- Volume
- 50
- Issue
- 6
- Pages
- 4065-4076
- ISSN
- 0093-9994 (ISSN-L)
- 1939-9367
- OpenAlex
- W2334999169
- Cited by
- 253
- References
- 28
- FWCI
- 26.05
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.