Grid Voltage Synchronization for Distributed Generation Systems Under Grid Fault Conditions
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
The actual grid code requirements for the grid connection of distributed generation systems, mainly wind and photovoltaic (PV) systems, are becoming very demanding. The transmission system operators (TSOs) are especially concerned about the low-voltage-ride-through requirements. Solutions based on the installation of STATCOMs and dynamic voltage regulators (DVRs), as well as on advanced control functionalities for the existing power converters of distributed generation plants, have contributed to enhance their response under faulty and distorted scenarios and, hence, to fulfill these requirements. In order to achieve satisfactory results with such systems, it is necessary to count on accurate and fast grid voltage synchronization algorithms, which are able to work under unbalanced and distorted conditions. This paper analyzes the synchronization capability of three advanced synchronization systems: the decoupled double synchronous reference frame phase-locked loop (PLL), the dual second order generalized integrator PLL, and the three-phase enhanced PLL, designed to work under such conditions. Although other systems based on frequency-locked loops have also been developed, PLLs have been chosen due to their link with dq0 controllers. In the following, the different algorithms will be presented and discretized, and their performance will be tested in an experimental setup controlled in order to evaluate their accuracy and implementation features.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Overview of Control and Grid Synchronization for Distributed Power Generation Systems
Blaabjerg, F., Teodorescu, R., Liserre, M., & Timbus, A. V. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.881997 · Cited by 5,220 · cited 1×
“[30].”
Self-citationComputer controlled systems theory and design
(1986) · Automatica · doi:10.1016/0005-1098(86)90095-6 · Cited by 3,003
Analysis of Electric Machinery and Drive Systems
(2013) · Wiley eBooks · doi:10.1002/9781118524336 · Cited by 2,678
Computer-controlled systems: Theory and design
Johnson, C. R. (1985) · Automatica · doi:10.1016/0005-1098(85)90050-0 · Cited by 2,364
Analysis of Electric Machinery and Drive Systems
Krause, P. C., Wasynczuk, O., & Sudhoff, S. D. (2002) · Institute of Electrical and Electronics Engineers eBooks · doi:10.1109/9780470544167 · Cited by 2,314
Digital control of dynamic systems
Anderson, B. (1981) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1981.1163502 · Cited by 1,690
(2005) · Nonconvex Optimization and Its Applications · doi:10.1007/0-387-28154-1_8 · Cited by 1,550 · cited 1×
“Some methods, such as the forward Euler, the backward Euler, and the Tustin (trapezoidal) numerical integration, offer a good performance when used for discretizing other synchronization systems, as shown in [46] and [47].”
MethodA review of grid code technical requirements for wind farms
Tsili, M., & Papathanassiou, S. (2009) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2008.0070 · Cited by 1,373 · cited 1×
“Such requirements are known as low voltage ride through (LVRT) and are described by a voltage versus time characteristic [7].”
BackgroundDecoupled Double Synchronous Reference Frame PLL for Power Converters Control
Rodriguez, P., Pou, J., Bergas, J., Candela, J. I., Burgos, R. P., & Boroyevich, D. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.890000 · Cited by 1,359 · cited 2×
“A first-order filter with a cutoff frequency ωf , equal to half of the grid frequency, was originally proposed in [41]; hence, the same transfer function has been”
BackgroundMethodSelf-citationA phase tracking system for three phase utility interface inverters
Chung, S.-K. (2000) · IEEE Transactions on Power Electronics · doi:10.1109/63.844502 · Cited by 1,192 · cited 1×
“Some methods, such as the forward Euler, the backward Euler, and the Tustin (trapezoidal) numerical integration, offer a good performance when used for discretizing other synchronization systems, as shown in [46] and [47].”
MethodRidethrough of Wind Turbines with Doubly-Fed Induction Generator During a Voltage Dip
Morren, J., & deHaan, S. W. H. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.845526 · Cited by 931 · cited 1×
“Likewise, variable speed wind power systems may lose controllability in the injection of active/reactive power due to the disconnection of the rotor side converter under such conditions [10], [11].”
BackgroundOperation of a phase locked loop system under distorted utility conditions
Kaura, V., & Blasko, V. (2002) · Proceedings of Applied Power Electronics Conference. APEC '96 · doi:10.1109/apec.1996.500517 · Cited by 903 · cited 1×
“In the actual grid code requirements (GCRs), special constraints for the operation of such plants under grid voltage fault conditions have gained a great importance.”
BackgroundYuan, X., Merk, W., Stemmler, H., & Allmeling, J. (2002) · IEEE Transactions on Industry Applications · doi:10.1109/28.993175 · Cited by 896
Rodríguez, P., Teodorescu, R., Candela, I., Timbus, A. V., Liserre, M., & Blaabjerg, F. (2006) · 2006 37th IEEE Power Electronics Specialists Conference · doi:10.1109/pesc.2006.1712059 · Cited by 842 · cited 14×
“As has been shown, this feature simplifies the structure of the DSOGI PLL and the DDSRF PLL, which allows reducing the computational burden, as compared to the 3phEPLL, without affecting its performance.”
BackgroundInfluentialSelf-citationGrid Code, high and extra high voltage
Netz, E. O. (2006) · Medical Entomology and Zoology · Cited by 835
Flexible Active Power Control of Distributed Power Generation Systems During Grid Faults
Rodriguez, P., Timbus, A. V., Teodorescu, R., Liserre, M., & Blaabjerg, F. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.899914 · Cited by 726 · cited 1×
“under balanced and unbalanced fault conditions, relevant contributions, such as [20]–[29], can be found in the literature.”
BackgroundSelf-citationYuan, X., Allmeling, J., Merk, W., & Stemmler, H. (2002) · Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129) · doi:10.1109/ias.2000.883122 · Cited by 663 · cited 1×
“In the DSOGI PLL, the signals to be supplied to the ISC method are obtained by using a dual second order generalized integrator (DSOGI), which is an adaptive bandpass filter based on the generalized integrator concept [42].”
MethodKarimi-Ghartemani, M., & Iravani, M. R. (2004) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2004.831280 · Cited by 575 · cited 1×
“The enhanced phase-locked loop (EPLL) is a synchronization system that has proven to provide good results in singlephase synchronization systems [43].”
BackgroundComparison of Three Single-Phase PLL Algorithms for UPS Applications
Santos Filho, R. M., Seixas, P. F., Cortizo, P. C., Torres, L. A. B., & Souza, A. F. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.924205 · Cited by 469 · cited 1×
“Despite the fact that the detection of the fault can be carried out with simpler algorithms, as shown in [39] and [40], the importance of advanced grid synchronization systems lies in the”
BackgroundLow Voltage Ride Through of Wind Farms With Cage Generators: STATCOM Versus SVC
Molinas, M., Suul, J. A., & Undeland, T. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.921169 · Cited by 426 · cited 1×
“Solutions based on the development of auxiliary systems, such as STATCOMs and dynamic voltage regulators (DVRs), have played a decisive role in enhancing the fault ride through (FRT) capability of distributed generation systems, as demonstrated in [12]–[16].”
BackgroundControl Strategies Based on Symmetrical Components for Grid-Connected Converters Under Voltage Dips
Alepuz, S., Busquets-Monge, S., Bordonau, J., Martinez-Velasco, J. A., Silva, C. A., Pontt, J., & Rodriguez, J. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2017102 · Cited by 373
Timbus, A., Liserre, M., Teodorescu, R., & Blaabjerg, F. (2006) · IEEE 36th Conference on Power Electronics Specialists, 2005. · doi:10.1109/pesc.2005.1581980 · Cited by 347 · cited 1×
“[31]–[33].”
Self-citationIndividual Voltage Balancing Strategy for PWM Cascaded H-Bridge Converter-Based STATCOM
Barrena, J. A., Marroyo, L., Rodriguez Vidal, M. Á., & Torrealday Apraiz, J. R. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.906127 · Cited by 335
A nonlinear adaptive filter for online signal analysis in power systems: applications
Karimi-Ghartemani, M., & Iravani, M. R. (2002) · IEEE Transactions on Power Delivery · doi:10.1109/61.997949 · Cited by 301
A Flexible Selective Harmonic Mitigation Technique to Meet Grid Codes in Three-Level PWM Converters
Franquelo, L. G., Napoles, J., Guisado, R. C. P., Leon, J. I., & Aguirre, M. A. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.907045 · Cited by 264
Zeng, Q., & Chang, L. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.907674 · Cited by 231
A Nonlinear Adaptive Filter for Online Signal Analysis in Power Systems: Applications
Karimi-Ghartemani, M., & Iravani, M. R. (2002) · IEEE Power Engineering Review · doi:10.1109/mper.2002.4311701 · Cited by 226 · cited 1×
“synchronous reference frame PLL (DDSRF PLL) [34], the dual second order generalized integrator PLL (DSOGI PLL), [35] and the three-phase enhanced PLL (3phEPLL) [36].”
BackgroundSantos-Martin, D., Rodriguez-Amenedo, J. L., & Arnalte, S. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2001907 · Cited by 190 · cited 1×
“Likewise, advanced control functionalities for the power converters have also been proposed [17], [18].”
BackgroundControl of Three-Level PWM Converter Applied to Variable-Speed-Type Turbines
Malinowski, M., Styński, S., Kolomyjski, W., & Kaźmierkowski, M. P. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.927245 · Cited by 140
Mitigation of Unbalanced Voltage Dips Using Static Series Compensator
Awad, H. E.-S., Svensson, J., & Bollen, M. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.826536 · Cited by 111
High-Speed Fault Classification in Power Lines: Theory and FPGA-Based Implementation
Valsan, S. P., & Swarup, K. S. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2011055 · Cited by 62 · cited 1×
“R2, presented at the 2012 IEEE Energy Conversion Congress and Exposition, Raleigh, NC, USA, September 15–20, and approved for publication in the IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS by the Sustainable Energy Conversion Systems Committee of the IEEE Industry Applications Society.”
BackgroundDiscrete-Time Signals and Systems
Haugen, F. (2006) · Springer eBooks · doi:10.1007/0-387-28666-7_2 · Cited by 18
Cited by
Grid-Synchronization Stability of Converter-Based Resources—An Overview
Wang, X., Taul, M. G., Wu, H., Liao, Y., Blaabjerg, F., & Harnefors, L. (2020) · IEEE Open Journal of Industry Applications · doi:10.1109/ojia.2020.3020392 · Cited by 862
Self-citationTaul, M. G., Wang, X., Davari, P., & Blaabjerg, F. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2892142 · Cited by 415
Self-citationCatalán, P., Wang, Y., Arza, J., & Chen, Z. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3234221 · Cited by 197
“of PLL-based synchronization structures has been developed comprising the diverse research efforts, such as harmonics elimination or grid fault operation [143], [144].”
MethodFast and Robust Phase Estimation Algorithm for Heavily Distorted Grid Conditions
Zheng, L., Geng, H., & Yang, G. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2585078 · Cited by 83
Metadata
- Authors
- Luna, A., Rocabert, J., Candela, J. I., Hermoso, J. R., Teodorescu, R., Blaabjerg, F., & Rodriguez, P.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2015-07
- Volume
- 51
- Issue
- 4
- Pages
- 3414-3425
- ISSN
- 0093-9994 (ISSN-L)
- 1939-9367
- OpenAlex
- W2049042130
- Cited by
- 201
- References
- 32
- FWCI
- 20.72
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.