The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Output Impedance Design of Parallel-Connected UPS Inverters With Wireless Load-Sharing Control
Abstract
This paper deals with the design of the output impedance of uninterruptible power system (UPS) inverters with parallel-connection capability. In order to avoid the need for any communication among modules, the power-sharing control loops are based on the P/Q droop method. Since in these systems the power-sharing accuracy is highly sensitive to the inverters output impedance, novel control loops to achieve both stable output impedance and proper power balance are proposed. In this sense, a novel wireless controller is designed by using three nested loops: 1) the inner loop is performed by using feedback linearization control techniques, providing a good quality output voltage waveform; 2) the intermediate loop enforces the output impedance of the inverter, achieving good harmonic power sharing while maintaining low output voltage total harmonic distortion; and 3) the outer loop calculates the output active and reactive powers and adjusts the output impedance value and the output voltage frequency during the load transients, obtaining excellent power sharing without deviations in either the frequency or the amplitude of the output voltage. Simulation and experimental results are reported from a parallel-connected UPS system sharing linear and nonlinear loads.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Isidori, A. (1989) · Springer eBooks · doi:10.1007/978-3-662-02581-9 · Cited by 7,869
Isidori, A. (1995) · Communications and Control Engineering · doi:10.1007/978-1-84628-615-5 · Cited by 6,755
(2012) · SpringerReference · doi:10.1007/springerreference_117570 · Cited by 4,486
Control of parallel connected inverters in standalone AC supply systems
Chandorkar, M. C., Divan, D. M., & Adapa, R. (1993) · IEEE Transactions on Industry Applications · doi:10.1109/28.195899 · Cited by 1,766
Guerrero, J. M., GarciadeVicuna, L., Matas, J., Castilla, M., & Miret, J. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833451 · Cited by 1,039
Self-citationSmall-signal stability for parallel-connected inverters in stand-alone AC supply systems
Coelho, E. A. A., Cortizo, P. C., & Garcia, P. F. D. (2002) · IEEE Transactions on Industry Applications · doi:10.1109/28.993176 · Cited by 662
Control topology options for single-phase UPS inverters
Ryan, M. J., Brumsickle, W. E., & Lorenz, R. D. (1997) · IEEE Transactions on Industry Applications · doi:10.1109/28.568015 · Cited by 429
Parallel operation of single phase inverter modules with no control interconnections
Tuladhar, A., Jin, H., Unger, T., & Mauch, K. (2002) · Proceedings of APEC 97 - Applied Power Electronics Conference · doi:10.1109/apec.1997.581439 · Cited by 315
Parallel operation of inverters for distributed photovoltaic power supply system
Hua, C., Liao, K.-A., & Lin, J.-R. (2003) · IEEE Power Electronics Specialists Conference (PESC) · doi:10.1109/psec.2002.1023104 · Cited by 66
Cited by
Guerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075
Self-citationControl of Power Converters in AC Microgrids
Rocabert, J., Luna, A., Blaabjerg, F., & Rodríguez, P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2199334 · Cited by 3,723
Olivares, D. E., Mehrizi-Sani, A., Etemadi, A. H., Canizares, C. A., Iravani, R., Kazerani, M., Hajimiragha, A. H., Gomis-Bellmunt, O., Saeedifard, M., Palma-Behnke, R., et al. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2295514 · Cited by 3,137
“inaccuracy and active/reactive power coupling in distribution networks, the control loop is augmented with a virtual inductive output impedance in [79], [84], [85].”
BackgroundGuerrero, J. M., Chandorkar, M., Lee, T.-L., & Loh, P. C. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2194969 · Cited by 1,976
Self-citationHierarchical Structure of Microgrids Control System
Bidram, A., & Davoudi, A. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2197425 · Cited by 1,515
Metadata
- Authors
- Guerrero, J. M., GarciadeVicuna, L., Matas, J., Castilla, M., & Miret, J.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2005-08
- Volume
- 52
- Issue
- 4
- Pages
- 1126-1135
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2124708943
- Cited by
- 1,221
- References
- 9
- FWCI
- 23.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.