The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Overview of Control and Grid Synchronization for Distributed Power Generation Systems
Abstract
Renewable energy sources like wind, sun, and hydro are seen as a reliable alternative to the traditional energy sources such as oil, natural gas, or coal. Distributed power generation systems (DPGSs) based on renewable energy sources experience a large development worldwide, with Germany, Denmark, Japan, and USA as leaders in the development in this field. Due to the increasing number of DPGSs connected to the utility network, new and stricter standards in respect to power quality, safe running, and islanding protection are issued. As a consequence, the control of distributed generation systems should be improved to meet the requirements for grid interconnection. This paper gives an overview of the structures for the DPGS based on fuel cell, photovoltaic, and wind turbines. In addition, control structures of the grid-side converter are presented, and the possibility of compensation for low-order harmonics is also discussed. Moreover, control strategies when running on grid faults are treated. This paper ends up with an overview of synchronization methods and a discussion about their importance in the control
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fundamentals of Power Electronics
Erickson, R. W., & Maksimović, D. (2001) · Springer eBooks · doi:10.1007/b100747 · Cited by 6,112
Fundamentals of Power Electronics
Erickson, R. W., & Maksimović, D. (2020) · Springer eBooks · doi:10.1007/978-3-030-43881-4 · Cited by 5,420
(2005) · Wiley eBooks · doi:10.1002/0470012684 · Cited by 2,915
Power electronics as efficient interface in dispersed power generation systems
Blaabjerg, F., Chen, Z., & Kjaer, S. B. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833453 · Cited by 2,588
Self-citationUnderstanding power quality problems: voltage sags and interruptions
(2000) · Choice Reviews Online · doi:10.5860/choice.37-4522 · Cited by 1,791
Grid Integration of Wind Energy Conversion Systems
Heier, S. (1998) · Cited by 1,619
Stationary frame current regulation of PWM inverters with zero steady-state error
Zmood, D. N., & Holmes, D. G. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.810852 · Cited by 1,518
A phase tracking system for three phase utility interface inverters
Chung, S.-K. (2000) · IEEE Transactions on Power Electronics · doi:10.1109/63.844502 · Cited by 1,192
Operation of a phase locked loop system under distorted utility conditions
Kaura, V., & Blasko, V. (1997) · IEEE Transactions on Industry Applications · doi:10.1109/28.567077 · Cited by 997
Dual current control scheme for PWM converter under unbalanced input voltage conditions
Song, H.-S., & Nam, K. (1999) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.793344 · Cited by 930
Operation of a phase locked loop system under distorted utility conditions
Kaura, V., & Blasko, V. (2002) · Proceedings of Applied Power Electronics Conference. APEC '96 · doi:10.1109/apec.1996.500517 · Cited by 903
Grid current regulation of a three-phase voltage source inverter with an LCL input filter
Twining, E., & Holmes, D. G. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.810838 · Cited by 901
Control in Power Electronics: selected problems
Kaźmierkowski, M. P., Krishnan, R., & Blaabjerg, F. (2002) · Cited by 873
Self-citationYuan, X., Merk, W., Stemmler, H., & Allmeling, J. (2002) · IEEE Transactions on Industry Applications · doi:10.1109/28.993175 · Cited by 815
Phase-locked loop techniques. A survey
Hsieh, G.-C., & Hung, J. C. (1996) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.544547 · Cited by 784
A boost DC-AC converter: analysis, design, and experimentation
Caceres, R. O., & Barbi, I. (1999) · IEEE Transactions on Power Electronics · doi:10.1109/63.737601 · Cited by 736
Yuan, X., Allmeling, J., Merk, W., & Stemmler, H. (2002) · Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129) · doi:10.1109/ias.2000.883122 · Cited by 663
Karimi-Ghartemani, M., & Iravani, M. R. (2004) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2004.831280 · Cited by 575
Bose, B. K. (1990) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.103436 · Cited by 535
Timbus, A., Liserre, M., Teodorescu, R., & Blaabjerg, F. (2006) · IEEE 36th Conference on Power Electronics Specialists, 2005. · doi:10.1109/pesc.2005.1581980 · Cited by 347
Self-citationNonlinear predictive control with application to manipulator with flexible forearm
Song, B. J., & Koivo, A. J. (1999) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.793340 · Cited by 332
Synchronisation methods for grid-connected voltage source converters
Svensson, J. (2001) · IEE Proceedings - Generation, Transmission and Distribution · doi:10.1049/ip-gtd:20010101 · Cited by 284
Control of single-stage single-phase PV inverter
Ciobotaru, M., Teodorescu, R., & Blaabjerg, F. (2005) · 2005 European Conference on Power Electronics and Applications · doi:10.1109/epe.2005.219501 · Cited by 184
Self-citationMoran, L., Ziogas, P. D., & Joos, G. (1992) · IEEE Transactions on Industry Applications · doi:10.1109/28.175279 · Cited by 174
A Novel Three-Phase Single-Stage Distributed Power Inverter
Cecati, C., Dell’Aquila, A., & Liserre, M. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.835112 · Cited by 113
Self-citation
Cited by
Control of Power Converters in AC Microgrids
Rocabert, J., Luna, A., Blaabjerg, F., & Rodríguez, P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2199334 · Cited by 3,723
Self-citationOlivares, D. E., Mehrizi-Sani, A., Etemadi, A. H., Canizares, C. A., Iravani, R., Kazerani, M., Hajimiragha, A. H., Gomis-Bellmunt, O., Saeedifard, M., Palma-Behnke, R., et al. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2295514 · Cited by 3,137
“microgrid, whereas inverter output controllers should control and regulate the output voltages and currents [19], [20], [32], [54], [55].”
BackgroundInfluentialImpedance-Based Stability Criterion for Grid-Connected Inverters
Sun, J. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2136439 · Cited by 2,574
Katiraei, F., Iravani, R., Hatziargyriou, N., & Dimeas, A. (2008) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2008.918702 · Cited by 1,591
Analysis of D-Q Small-Signal Impedance of Grid-Tied Inverters
Wen, B., Boroyevich, D., Burgos, R., Mattavelli, P., & Shen, Z. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2398192 · Cited by 1,334
Metadata
- Authors
- Blaabjerg, F., Teodorescu, R., Liserre, M., & Timbus, A. V.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2006-10
- Volume
- 53
- Issue
- 5
- Pages
- 1398-1409
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2132755931
- Cited by
- 5,220
- References
- 25
- FWCI
- 171.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.