The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Wireless-Control Strategy for Parallel Operation of Distributed-Generation Inverters
Abstract
In this paper, a method for the parallel operation of inverters in an ac-distributed system is proposed. This paper explores the control of active and reactive power flow through the analysis of the output impedance of the inverters and its impact on the power sharing. As a result, adaptive virtual output impedance is proposed in order to achieve a proper reactive power sharing, regardless of the line-impedance unbalances. A soft-start operation is also included, avoiding the initial current peak, which results in a seamless hot-swap operation. Active power sharing is achieved by adjusting the frequency in load transient situations only, owing to which the proposed method obtains a constant steady-state frequency and amplitude. As opposed to the conventional droop method, the transient response can be modified by acting on the main control parameters. Linear and nonlinear loads can be properly shared due to the addition of a current harmonic loop in the control strategy. Experimental results are presented from a two-6-kVA parallel-connected inverter system, showing the feasibility of the proposed approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Control of parallel connected inverters in standalone AC supply systems
Chandorkar, M. C., Divan, D. M., & Adapa, R. (1993) · IEEE Transactions on Industry Applications · doi:10.1109/28.195899 · Cited by 1,766
Output Impedance Design of Parallel-Connected UPS Inverters With Wireless Load-Sharing Control
Guerrero, J. M., GarciadeVicuna, L., Matas, J., Castilla, M., & Miret, J. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.851634 · Cited by 1,221
Self-citationGuerrero, J. M., GarciadeVicuna, L., Matas, J., Castilla, M., & Miret, J. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833451 · Cited by 1,039
Self-citationKarimi-Ghartemani, M., & Iravani, M. R. (2004) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2004.831280 · Cited by 575
Control of Distributed Generation Systems— Part II: Load Sharing Control
Marwali, M. N., Jung, J.-W., & Keyhani, A. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.836634 · Cited by 438
Parallel operation of single phase inverter modules with no control interconnections
Tuladhar, A., Jin, H., Unger, T., & Mauch, K. (2002) · Proceedings of APEC 97 - Applied Power Electronics Conference · doi:10.1109/apec.1997.581439 · Cited by 315
Control techniques of Dispersed Generators to improve the continuity of electricity supply
Barsali, S., Ceraolo, M., Pelacchi, P., & Poli, D. (2003) · 2002 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.02CH37309) · doi:10.1109/pesw.2002.985115 · Cited by 306
Ro, K., & Rahman, S. (1998) · IEEE Transactions on Energy Conversion · doi:10.1109/60.707608 · Cited by 224
Stavrakakis, G. S., & Kariniotakis, G. N. (1995) · IEEE Transactions on Energy Conversion · doi:10.1109/60.464885 · Cited by 202
Concerns generated by islanding
Villeneuve, P. L. (2004) · IEEE Power and Energy Magazine · doi:10.1109/mpae.2004.1293600 · Cited by 89
Kariniotakis, G., & Stavrakakis, G. S. (1995) · IEEE Transactions on Energy Conversion · doi:10.1109/60.464886 · Cited by 71
Parallel operation of inverters for distributed photovoltaic power supply system
Hua, C., Liao, K.-A., & Lin, J.-R. (2003) · IEEE Power Electronics Specialists Conference (PESC) · doi:10.1109/psec.2002.1023104 · Cited by 66
Cited by
Guerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075
Self-citationControl of Power Converters in AC Microgrids
Rocabert, J., Luna, A., Blaabjerg, F., & Rodríguez, P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2199334 · Cited by 3,723
Guerrero, J. M., Chandorkar, M., Lee, T.-L., & Loh, P. C. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2194969 · Cited by 1,976
Self-citationHierarchical Structure of Microgrids Control System
Bidram, A., & Davoudi, A. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2197425 · Cited by 1,515
Guerrero, J. M., Matas, J., Garcia de Vicuna, L., Castilla, M., & Miret, J. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.892621 · Cited by 1,085
Self-citation
Metadata
- Authors
- Guerrero, J. M., Matas, J., Garcia De Vicunagarcia De Vicuna, L., Castilla, M., & Miret, J.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2006-10
- Volume
- 53
- Issue
- 5
- Pages
- 1461-1470
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2079746763
- Cited by
- 662
- References
- 12
- FWCI
- 38.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.