The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Induction Machine Broken Bar and Stator Short-Circuit Fault Diagnostics Based on Three-Phase Stator Current Envelopes
Abstract
A new method for the fault diagnosis of a broken rotor bar and interturn short circuits in induction machines (IMs) is presented. The method is based on the analysis of the three-phase stator current envelopes of IMs using reconstructed phase space transforms. The signatures of each type of fault are created from the three-phase current envelope of each fault. The resulting fault signatures for the new so-called ldquounseen signalsrdquo are classified using Gaussian mixture models and a Bayesian maximum likelihood classifier. The presented method yields a high degree of accuracy in fault identification as evidenced by the given experimental results, which validate this method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2012) · Encyclopedia of the Sciences of Learning · doi:10.1007/978-1-4419-1428-6_5195 · Cited by 19,370
Discrete-Time Signal Processing
Oppenheim, A. V., & Schafer, R. W. (1989) · Cited by 12,572
Detecting strange attractors in turbulence
Takens, F. (1981) · Lecture Notes in Mathematics · doi:10.1007/bfb0091924 · Cited by 10,459 · cited 1×
“This RPS-based approach allows for the reconstruction of an IM’s state structure [30], [31].”
Chiang, L. H., Russell, E. L., & Braatz, R. D. (2001) · Advanced Textbooks in Control and Signal Processing · doi:10.1007/978-1-4471-0347-9_3 · Cited by 5,003
Discrete-time Signal Processing
Williamson, D. (1999) · Advanced Textbooks in Control and Signal Processing · doi:10.1007/978-1-4471-0541-1 · Cited by 4,858
The expectation-maximization algorithm
Moon, T. K. (1996) · IEEE Signal Processing Magazine · doi:10.1109/79.543975 · Cited by 3,181
Pattern Classification (2nd ed.)
Duda, R. O., Hart, P. E., & Stork, D. G. (1999) · Cited by 2,520
Nonlinear Time Series Analysis
(2005) · Technometrics · doi:10.1198/tech.2005.s306 · Cited by 2,109
Sauer, T., Yorke, J. A., & Casdagli, M. (1991) · Journal of Statistical Physics · doi:10.1007/bf01053745 · Cited by 2,045
Analysis of Observed Chaotic Data
Abarbanel, H. D. I., & Gollub, J. P. (1996) · Physics Today · doi:10.1063/1.881528 · Cited by 1,821
A review of induction motors signature analysis as a medium for faults detection
El Hachemi Benbouzid, M. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873206 · Cited by 1,602
Analysis of Observed Chaotic Data
Abarbanel, H. D. I. (1996) · Institute for Nonlinear Science · doi:10.1007/978-1-4612-0763-4 · Cited by 1,189
Weiss, S. M., & Kulikowski, C. A. (1991) · Morgan Kaufmann Publishers Inc. eBooks · Cited by 898
A Review of Stator Fault Monitoring Techniques of Induction Motors
Siddique, A., Yadava, G. S., & Singh, B. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2004.837304 · Cited by 591
Online Diagnosis of Induction Motors Using MCSA
Jung, J.-H., Lee, J.-J., & Kwon, B.-H. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.885131 · Cited by 570
Condition monitoring and fault diagnosis of electrical machines-a review
Nandi, S., & Toliyat, H. A. (2003) · Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370) · doi:10.1109/ias.1999.799956 · Cited by 531
Noninvasive detection of broken rotor bars in operating induction motors
Kliman, G. B., Koegl, R. A., Stein, J., Endicott, R. D., & Madden, M. W. (1988) · IEEE Transactions on Energy Conversion · doi:10.1109/60.9364 · Cited by 525
Quantitative evaluation of induction motor broken bars by means of electrical signature analysis
Bellini, A., Filippetti, F., Franceschini, G., Tassoni, C., & Kliman, G. B. (2001) · IEEE Transactions on Industry Applications · doi:10.1109/28.952499 · Cited by 483
Dorrell, D. G., Thomson, W. T., & Roach, S. (1997) · IEEE Transactions on Industry Applications · doi:10.1109/28.567073 · Cited by 450
Detection and location of interturn short circuits in the stator windings of operating motors
Penman, J., Sedding, H. G., Lloyd, B. A., & Fink, W. T. (1994) · IEEE Transactions on Energy Conversion · doi:10.1109/60.368345 · Cited by 394
Dorrell, D. G., Thomson, W. T., & Roach, S. (2002) · IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting · doi:10.1109/ias.1995.530349 · Cited by 367
Induction Machine Condition Monitoring Using Neural Network Modeling
Su, H., & Chong, K. T. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.888786 · Cited by 271
Ballal, M. S., Khan, Z. J., Suryawanshi, H. M., & Sonolikar, R. L. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.888789 · Cited by 251
Neural networks aided on-line diagnostics of induction motor rotor faults
Filippetti, F., Franceschini, G., & Tassoni, C. (1995) · IEEE Transactions on Industry Applications · doi:10.1109/28.395301 · Cited by 216
Induction motor stator faults diagnosis by a current concordia pattern-based fuzzy decision system
Zidani, F., El Hachemi Benbouzid, M., Diallo, D., & Nait-Said, M. S. (2003) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2003.815832 · Cited by 183
Ayhan, B., Chow, M.-Y., & Song, M.-H. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.878301 · Cited by 182
Time series classification using Gaussian mixture models of reconstructed phase spaces
Povinelli, R. J., Johnson, M. T., Lindgren, A. C., et al. (2004) · IEEE Transactions on Knowledge and Data Engineering · doi:10.1109/tkde.2004.17 · Cited by 178
Self-citationComparative investigation of diagnostic media for induction motors: a case of rotor cage faults
Trzynadlowski, A. M., & Ritchie, E. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873218 · Cited by 152
A Generic Neurofuzzy Model-Based Approach for Detecting Faults in Induction Motors
Tan, W. W., & Huo, H. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.855654 · Cited by 75
Lasurt, I., Stronach, A. F., & Penman, J. (2002) · PeachFuzz 2000. 19th International Conference of the North American Fuzzy Information Processing Society - NAFIPS (Cat. No.00TH8500) · doi:10.1109/nafips.2000.877411 · Cited by 30 · cited 2×
“approaches have been introduced, using concepts such as fuzzy logic [ 12-14 ], genetic algorithms [11,”
Method
Cited by
From Model, Signal to Knowledge: A Data-Driven Perspective of Fault Detection and Diagnosis
Dai, X., & Gao, Z. (2013) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2013.2243743 · Cited by 728
A Survey of Condition Monitoring and Protection Methods for Medium-Voltage Induction Motors
Zhang, P., Du, Y., Habetler, T. G., & Lu, B. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2010.2090839 · Cited by 706
Gangsar, P., & Tiwari, R. (2020) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2020.106908 · Cited by 605
Recent Advances in Modeling and Online Detection of Stator Interturn Faults in Electrical Motors
Gandhi, A., Corrigan, T., & Parsa, L. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2089937 · Cited by 544
A survey of condition monitoring and protection methods for medium voltage induction motors
Zhang, P., Du, Y., Habetler, T. G., & Lu, B. (2009) · 2009 IEEE Energy Conversion Congress and Exposition · doi:10.1109/ecce.2009.5316083 · Cited by 524
Metadata
- Authors
- da Silva, A. M., Povinelli, R. J., & Demerdash, N. A. O.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2008-03
- Volume
- 55
- Issue
- 3
- Pages
- 1310-1318
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2100092033
- Cited by
- 266
- References
- 30
- FWCI
- 35.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.