Control of Distributed Uninterruptible Power Supply Systems
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
In the last years, the use of distributed uninterruptible power supply (UPS) systems has been growing into the market, becoming an alternative to large conventional UPS systems. In addition, with the increasing interest in renewable energy integration and distributed generation, distributed UPS systems can be a suitable solution for storage energy in micro grids. This paper depicts the most important control schemes for the parallel operation of UPS systems. Active load-sharing techniques and droop control approaches are described. The recent improvements and variants of these control techniques are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Control of parallel connected inverters in standalone AC supply systems
Chandorkar, M. C., Divan, D. M., & Adapa, R. (1993) · IEEE Transactions on Industry Applications · doi:10.1109/28.195899 · Cited by 1,766
Output Impedance Design of Parallel-Connected UPS Inverters With Wireless Load-Sharing Control
Guerrero, J. M., GarciadeVicuna, L., Matas, J., Castilla, M., & Miret, J. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.851634 · Cited by 1,221
Self-citationGuerrero, J. M., Matas, J., Garcia de Vicuna, L., Castilla, M., & Miret, J. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.892621 · Cited by 1,085
Self-citationGuerrero, J. M., GarciadeVicuna, L., Matas, J., Castilla, M., & Miret, J. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833451 · Cited by 1,039
Self-citationWireless-Control Strategy for Parallel Operation of Distributed-Generation Inverters
Guerrero, J. M., Matas, J., Garcia De Vicunagarcia De Vicuna, L., Castilla, M., & Miret, J. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.882015 · Cited by 662
Self-citationSmall-signal stability for parallel-connected inverters in stand-alone AC supply systems
Coelho, E. A. A., Cortizo, P. C., & Garcia, P. F. D. (2002) · IEEE Transactions on Industry Applications · doi:10.1109/28.993176 · Cited by 662
Control of Distributed Generation Systems— Part II: Load Sharing Control
Marwali, M. N., Jung, J.-W., & Keyhani, A. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.836634 · Cited by 438
Parallel operation of single phase inverter modules with no control interconnections
Tuladhar, A., Jin, H., Unger, T., & Mauch, K. (2002) · Proceedings of APEC 97 - Applied Power Electronics Conference · doi:10.1109/apec.1997.581439 · Cited by 315
3C strategy for inverters in parallel operation achieving an equal current distribution
Wu, T.-F., Chen, Y.-K., & Huang, Y.-H. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.836342 · Cited by 269
Sun, X., Lee, Y.-S., & Xu, D. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.810867 · Cited by 259
Uninterruptible power supply systems provide protection
Guerrero, J. M., Garcia De Vicuna, L., & Uceda, J. (2007) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2007.357184 · Cited by 203
Self-citationMultiple-Loop H-Infinity Control Design for Uninterruptible Power Supplies
Willmann, G., Coutinho, D. F., Pereira, L. F. A., & Libano, F. B. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.894721 · Cited by 190
Auto-master-slave control technique of parallel inverters in distributed AC power systems and UPS
Pei, Y., Jiang, G., Xu, Y., & Wang, Z. (2004) · IEEE Power Electronics Specialists Conference (PESC) · doi:10.1109/pesc.2004.1355433 · Cited by 143
Karve, S. (2000) · IEE Review · doi:10.1049/ir:20000204 · Cited by 129
An On-Line UPS System With Power Factor Correction and Electric Isolation Using BIFRED Converter
Nasiri, A., Nie, Z., Bekiarov, S. B., & Emadi, A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.911199 · Cited by 104
Current limitation control technique for parallel operation of UPS inverters
Chiang, S. J., Lin, C. H., & Yen, C. Y. (2005) · PESC record · doi:10.1109/pesc.2004.1355411 · Cited by 44
Cited by
Guerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075
Self-citationControl of Power Converters in AC Microgrids
Rocabert, J., Luna, A., Blaabjerg, F., & Rodríguez, P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2199334 · Cited by 3,723
Olivares, D. E., Mehrizi-Sani, A., Etemadi, A. H., Canizares, C. A., Iravani, R., Kazerani, M., Hajimiragha, A. H., Gomis-Bellmunt, O., Saeedifard, M., Palma-Behnke, R., et al. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2295514 · Cited by 3,137
“2) Non-Droop-Based Methods: The following control methods address primary control in a multi-DER microgrid from a centralized perspective: • A centralized controller is proposed in [93], [96], where the total load current is measured and transmitted to a central controller.”
MethodHierarchical Structure of Microgrids Control System
Bidram, A., & Davoudi, A. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2197425 · Cited by 1,515
DC Microgrids—Part II: A Review of Power Architectures, Applications, and Standardization Issues
Dragicevic, T., Lu, X., Vasquez, J. C., & Guerrero, J. M. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2464277 · Cited by 1,451
Self-citation
Metadata
- Authors
- Guerrero, J. M., Hang, L., & Uceda, J.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2008-08
- Volume
- 55
- Issue
- 8
- Pages
- 2845-2859
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2118910576
- Cited by
- 700
- References
- 16
- FWCI
- 45.66
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.