Global Loss Evaluation Methods for Nonsinusoidally Fed Medium-Frequency Power Transformers
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
Medium-voltage conversion systems, such as traction and grid-connected converters, are continuously evolving toward higher power densities. Consequently, volume, weight, and material reductions are becoming major design issues, which lead the research focus toward high-/medium-frequency isolated power conversion systems. An optimized design of these conversion systems requires a detailed transformer-loss evaluation considering both copper and core losses. This paper presents a simple and flexible methodology to analyze global medium-frequency transformer losses in an isolated DC-DC converter fed by general nonsinusoidal waveforms. Various loss evaluation approaches are considered, pointing out their validity and limitations by means of finite-element simulations and experimental tests.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Theory of ferromagnetic hysteresis
Jiles, D. C., & Atherton, D. L. (1986) · Journal of Magnetism and Magnetic Materials · doi:10.1016/0304-8853(86)90066-1 · Cited by 2,287 · cited 1×
“They can be subdivided into three main branches: hysteresis models [25], [26], loss separation approach [27], [28], and empirical methods [29]–[35].”
BackgroundGeneral properties of power losses in soft ferromagnetic materials
Bertotti, G. (1988) · IEEE Transactions on Magnetics · doi:10.1109/20.43994 · Cited by 2,162 · cited 1×
“They can be subdivided into three main branches: hysteresis models [25], [26], loss separation approach [27], [28], and empirical methods [29]–[35].”
Background�ber die magnetische Nachwirkung
Preisach, F. (1935) · Zeitschrift f�r Physik · doi:10.1007/bf01349418 · Cited by 1,989 · cited 1×
“They can be subdivided into three main branches: hysteresis models [25], [26], loss separation approach [27], [28], and empirical methods [29]–[35].”
BackgroundEffects of eddy currents in transformer windings
Dowell, P. L. (1966) · Proceedings of the Institution of Electrical Engineers · doi:10.1049/piee.1966.0236 · Cited by 1,438 · cited 8×
“However, if transposed or Litz wire winding is not an option, an optimal layer thickness along with a reduced edge distance will improve the thermal behavior of the transformer, at least within this frequency range, and will approach also Dowell’s prediction.”
InfluentialVenkatachalam, K., Sullivan, C. R., Abdallah, T., & Tacca, H. (2003) · 2002 IEEE Workshop on Computers in Power Electronics, 2002. Proceedings. · doi:10.1109/cipe.2002.1196712 · Cited by 1,145
Calculation of losses in ferro- and ferrimagnetic materials based on the modified Steinmetz equation
Reinert, J., Brockmeyer, A., & De Doncker, R. W. A. A. (2001) · IEEE Transactions on Industry Applications · doi:10.1109/28.936396 · Cited by 704
Improved calculation of core loss with nonsinusoidal waveforms
Li, J., Abdallah, T., & Sullivan, C. R. (2002) · Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248) · doi:10.1109/ias.2001.955931 · Cited by 531 · cited 1×
“Although the MSE proved considerable accuracy, the generalized Steinmetz equation (GSE) was introduced [32], aware of the mismatch between the OSE and the MSE for sinusoidal waveforms.”
MethodLin, D., Zhou, P., Fu, W. N., Badics, Z., & Cendes, Z. J. (2004) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2004.825025 · Cited by 425 · cited 2×
“The equivalent elliptical loop (EEL) approach [35] is based on the definition of an expression for the irreversible component of the magnetic field Hirr, the magnetic loss component.”
BackgroundMethodCalculation of losses in ferro- and ferrimagnetic materials based on the modified Steinmetz equation
Reinert, J., Brockmeyer, A., & De Doncker, R. W. (2003) · Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370) · doi:10.1109/ias.1999.806023 · Cited by 409 · cited 4×
“Based on a fairly general hypothesis which relates the rate of change of magnetic induction (dB(t)/dt) to core losses [31], it replaces the frequency parameter f in the OSE (3) with an equivalent frequency feq”
BackgroundMethodInfluentialSteinmetz, C. P. (1892) · Transactions of the American Institute of Electrical Engineers · doi:10.1109/t-aiee.1892.5570437 · Cited by 407 · cited 2×
“Steinmetz [29], [30] introduced, from the analysis of various loss curves, an expression for the characterization of magnetic loss density Pv”
Background
Cited by
Improved Core-Loss Calculation for Magnetic Components Employed in Power Electronic Systems
Muhlethaler, J., Biela, J., Kolar, J. W., & Ecklebe, A. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2162252 · Cited by 535
Core Losses Under the DC Bias Condition Based on Steinmetz Parameters
Muhlethaler, J., Biela, J., Kolar, J. W., & Ecklebe, A. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2160971 · Cited by 424
Optimal Design and Tradeoff Analysis of Planar Transformer in High-Power DC–DC Converters
Ouyang, Z., Thomsen, O. C., & Andersen, M. A. E. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2046005 · Cited by 393
Optimized design of medium frequency transformers with high isolation requirements
Ortiz, G., Biela, J., & Kolar, J. W. (2010) · IECON 2010 - 36th Annual Conference on IEEE Industrial Electronics Society · doi:10.1109/iecon.2010.5675240 · Cited by 159
“Further methods and comparison of them was performed in [23].”
MethodDesign and Optimization of a 200-kW Medium-Frequency Transformer for Medium-Voltage SiC PV Inverters
Guo, Z., Yu, R., Xu, W., Feng, X., & Huang, A. Q. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3059879 · Cited by 115
Huang, P., Mao, C., Wang, D., Wang, L., Duan, Y., Qiu, J., Xu, G., & Cai, H. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2674591 · Cited by 78
“In addition, for normal square wave excitation, core loss density for silicon steel core can be calculated as [1]”
BackgroundMethodInfluentialHigh Efficiency Integrated Transformer Design in DAB Converters for Solid-State Transformers
Lee, E. S., Park, J. H., Kim, M. Y., & Lee, J. S. (2022) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2022.3168561 · Cited by 63
Muhammad, R., Kieu, H.-P., Park, J., Tat-Thang, L., Choi, S., Jung, H., & Yoon, B.-K. (2022) · 2022 IEEE Applied Power Electronics Conference and Exposition (APEC) · doi:10.1109/apec43599.2022.9773511 · Cited by 15
“This cancellation not only eliminates the high-frequency flux that generates core loss [13], it also reduces the peak flux in the common leg so that its cross-sectional area can be reduced without driving the core to saturation as shown in Fig.”
Background
Metadata
- Authors
- Villar, I., Viscarret, U., Etxeberria-Otadui, I., & Rufer, A.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2009-10
- Volume
- 56
- Issue
- 10
- Pages
- 4132-4140
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2100424806
- Cited by
- 197
- References
- 33
- FWCI
- 5.54
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.