Fault-Tolerant Design and Control Strategy for Cascaded H-Bridge Multilevel Converter-Based STATCOM
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Cascaded H-bridge multilevel converter (CHMC) is a promising topology for flexible ac transmission systems such as static synchronous compensator (STATCOM) applications. Attention was drawn to the issue of converter reliability due to the large number of power devices used in CHMC applications. This paper proposed an effective fault-tolerant strategy by using H-bridge building block (HBBB) redundancy in CHMC-based STATCOM. The operating principle and the control strategy of the fault tolerance are proposed and discussed. The controller design consideration for the fault-tolerant STATCOM is presented. The proposed fault-tolerant control strategy is implemented on a seven-level CHMC-based STATCOM simulation platform and a five-level CHMC-based STATCOM hardware prototype. Simulation and experimental results are illustrated to verify the feasibility of the proposed fault-tolerant design with the HBBB redundancy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multilevel inverters: a survey of topologies, controls, and applications
Rodriguez, J., Lai, J.-S., & Peng, F. Z. (2002) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2002.801052 · Cited by 6,715
Hingorani, N. G., & Gyugyi, L. (1999) · doi:10.1109/9780470546802 · Cited by 4,233
Multilevel Voltage-Source-Converter Topologies for Industrial Medium-Voltage Drives
Rodriguez, J., Bernet, S., Wu, B., Pontt, J. O., & Kouro, S. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.907044 · Cited by 2,385
Control and Performance of a Transformerless Cascade PWM STATCOM With Star Configuration
Akagi, H., Inoue, S., & Yoshii, T. (2007) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2007.900487 · Cited by 643
Recent developments of high power converters for industry and traction applications
Bernet, S. (2000) · IEEE Transactions on Power Electronics · doi:10.1109/63.892825 · Cited by 458
Experimental fault-tolerant control of a PMSM drive
Bolognani, S., Zordan, M., & Zigliotto, M. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873223 · Cited by 382
Fault-Tolerant Voltage-Fed PWM Inverter AC Motor Drive Systems
de Araujo Ribeiro, R. L., Jacobina, C. B., da Silva, E. R. C., & Lima, A. M. N. (2004) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2004.825284 · Cited by 299
Operation of a Medium-Voltage Drive Under Faulty Conditions
Rodriguez, J., Hammond, P. W., Pontt, J., Musalem, R., Lezana, P., & Escobar, M. J. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.851645 · Cited by 282
Dynamic performance and control of a static VAr generator using cascade multilevel inverters
Peng, F. Z., & Lai, J.-S. (1997) · IEEE Transactions on Industry Applications · doi:10.1109/28.585865 · Cited by 243
Dynamic performance and control of a static VAr generator using cascade multilevel inverters
Peng, F. Z., & Lai, J.-S. (2002) · IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting · doi:10.1109/ias.1996.560205 · Cited by 233
Cited by
Survey on Reliability of Power Electronic Systems
Song, Y., & Wang, B. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2192503 · Cited by 861
Survey on Fault-Tolerant Techniques for Power Electronic Converters
Zhang, W., Xu, D., Enjeti, P. N., Li, H., Hawke, J. T., & Krishnamoorthy, H. S. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2304561 · Cited by 587
A General Review of Multilevel Inverters Based on Main Submodules: Structural Point of View
Vijeh, M., Rezanejad, M., Samadaei, E., & Bertilsson, K. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2890649 · Cited by 473
Fault Detection for Modular Multilevel Converters Based on Sliding Mode Observer
Shao, S., Wheeler, P. W., Clare, J. C., & Watson, A. J. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2242093 · Cited by 361
Real-Time Fault Detection and Identification for MMC Using 1-D Convolutional Neural Networks
Kiranyaz, S., Gastli, A., Ben-Brahim, L., Al-Emadi, N., & Gabbouj, M. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2833045 · Cited by 358
Fault Detection and Localization Method for Modular Multilevel Converters
Deng, F., Chen, Z., Khan, M. R., & Zhu, R. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2348194 · Cited by 266
Diagnosis and Tolerant Strategy of an Open-Switch Fault for T-Type Three-Level Inverter Systems
Choi, U.-M., Lee, K.-B., & Blaabjerg, F. (2014) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2013.2269531 · Cited by 257
Li, J., Huang, A. Q., Liang, Z., & Bhattacharya, S. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2143430 · Cited by 211
Self-citationRoshankumar, P., Rajeevan, P. P., Mathew, K., Gopakumar, K., Leon, J. I., & Franquelo, L. G. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2185714 · Cited by 200
“at reduced power level and, hence, this configuration is fault tolerant to some extent [17], [18].”
BackgroundShe, X., Huang, A. Q., Wang, F., & Burgos, R. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2216245 · Cited by 161
“redundant design can be incorporated to achieve fault-tolerant operation [27].”
BackgroundSelf-citationAnalysis and Experimental Verification of a Fault-Tolerant HEV Powertrain
Song, Y., & Wang, B. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2245513 · Cited by 81
“However, the proposed method in this paper differs from the existing methods that are based on the gating signals and collector-to-emitter voltages of IGBTs [39].”
MethodA modulation reconfiguration based fault-tolerant control scheme for modular multilevel converters
Shen, K., Xiao, B., Mei, J., Tolbert, L. M., Wang, J., Cai, X., & Ji, Y. (2013) · 2013 Twenty-Eighth Annual IEEE Applied Power Electronics Conference and Exposition (APEC) · doi:10.1109/apec.2013.6520766 · Cited by 58
“Conventional fault-tolerant methods can be classified as adding redundancy [6] or external circuits [7].”
BackgroundReliability comparison of fault-tolerant HVDC based modular multilevel converters
Alharbi, M., Bhattacharya, S., & Yousefpoor, N. (2017) · 2017 IEEE Power & Energy Society General Meeting · doi:10.1109/pesgm.2017.8274712 · Cited by 12
Metadata
- Authors
- Song, W., & Huang, A. Q.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2010-08
- Volume
- 57
- Issue
- 8
- Pages
- 2700-2708
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2096626066
- Cited by
- 358
- References
- 22
- FWCI
- 12.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.