CoChat

Reduction of Current Harmonic Distortion in Three-Phase Grid-Connected Photovoltaic Inverters via Resonant Current Control

Open access
Castilla, Miguel, Miret, Jaume, Camacho, Antonio, Matas, José, de Vicuna, Luis García · 2013 · IEEE Transactions on Industrial Electronics
Cited by 199

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Abstract

The resonant current control has been extensively employed to reduce the current harmonic distortion in a wide range of grid-connected distributed generation applications, including photovoltaic (PV) inverters, wind and water turbines, and fuel-cell inverters. However, the performance of these systems is deteriorated when the utility grid voltage experiences abnormal conditions such as voltage harmonics and imbalances. Several advanced control solutions have been recently introduced to cope with this problem but at the cost of a significant increase in the control computational load. This paper first analyzes the limitations of the standard resonant current control operating under abnormal grid conditions and then introduces a control scheme that improves the current harmonic distortion in such adverse conditions without increasing the computational load of the standard current control. This theoretical contribution is validated by means of selected experimental results from a three-phase PV inverter.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tie.2011.2167734

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Metadata

Authors
Castilla, M., Miret, J., Camacho, A., Matas, J., & de Vicuna, L. G.
Venue
IEEE Transactions on Industrial Electronics
Published
2013-04
Volume
60
Issue
4
Pages
1464-1472
ISSN
  • 0278-0046 (ISSN-L)
  • 1557-9948
OpenAlex
W2138536863
Cited by
199
References
22
FWCI
4.23
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.