The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Inter-Turn Fault Detection in PM Synchronous Machines by Physics-Based Back Electromotive Force Estimation
Abstract
In this paper, the inter-turn short circuit fault detection in permanent magnet synchronous machines (PMSM) using an open-loop physics-based back electromotive force (EMF) estimator is presented. The back EMF estimator is designed based upon a current mode tracking scheme. The thermal and saturation aspects of the machine are considered in the design of the estimator. The design procedure and stability criteria of the estimator are presented in detail. The fault detection is carried out based on the difference between the estimated back EMF and a reference back EMF. A 0.8 (kW) PMSM is studied experimentally as well as numerically under different inter-turn fault and operational contingencies. The numerical modeling is accomplished by a finite-element-based model coupled with the thermal network and polluted with inter-turn fault. The acceptable agreement between the simulated and experimental result validates the modeling process. The back EMF estimator fault detection system is led to discriminative inter-turn fault signatures in a fraction of second for wide speed range even in the presence of harmonic loads and dynamic eccentricities.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
A review of induction motors signature analysis as a medium for faults detection
El Hachemi Benbouzid, M. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873206 · Cited by 1,602
EL-Refaie, A. M. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2030211 · Cited by 1,373
Recent Advances in Modeling and Online Detection of Stator Interturn Faults in Electrical Motors
Gandhi, A., Corrigan, T., & Parsa, L. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2089937 · Cited by 544
Cruz, S. M. A., & Cardoso, A. J. M. (2001) · IEEE Transactions on Industry Applications · doi:10.1109/28.952496 · Cited by 464
Static-, Dynamic-, and Mixed-Eccentricity Fault Diagnoses in Permanent-Magnet Synchronous Motors
Ebrahimi, B. M., Faiz, J., & Roshtkhari, M. J. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2029577 · Cited by 386
Henao, H., Demian, C., & Capolino, G.-A. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.816531 · Cited by 361
A new approach to on-line turn fault detection in AC motors
Kliman, G. B., Premerlani, W. J., Koegl, R. A., & Hoeweler, D. (2002) · IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting · doi:10.1109/ias.1996.557113 · Cited by 303
Linear Feedback Control - Analysis and Design with MATLAB (by Dingyu Xue et al; 2007) [Bookshelf]
(2009) · IEEE Control Systems · doi:10.1109/mcs.2008.930839 · Cited by 291
Cruz, S. M. A., & Marques Cardoso, A. J. (2002) · Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129) · doi:10.1109/ias.2000.881141 · Cited by 258
Lee, S. B., Tallam, R. M., & Habetler, T. G. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.810848 · Cited by 248
Garcia-Perez, A., Romero-Troncoso, R. D. J., Cabal-Yepez, E., & Osornio-Rios, R. A. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2051398 · Cited by 235
Closed-loop control impact on the diagnosis of induction motors faults
Bellini, A., Filippetti, F., Franceschini, G., & Tassoni, C. (2000) · IEEE Transactions on Industry Applications · doi:10.1109/28.871280 · Cited by 199
Thermal Analysis of Multibarrier Interior PM Synchronous Machine Using Lumped Parameter Model
EL-Refaie, A. M., Harris, N. C., Jahns, T. M., & Rahman, K. M. (2004) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2004.827011 · Cited by 189
Stator winding turn-fault detection for closed-loop induction motor drives
Tallam, R. M., Habetler, T. G., & Harley, R. G. (2003) · Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344) · doi:10.1109/ias.2002.1043741 · Cited by 167
Online Model-Based Stator-Fault Detection and Identification in Induction Motors
De Angelo, C. H., Bossio, G. R., Giaccone, S. J., Valla, M. I., Solsona, J. A., & Garcia, G. O. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2012468 · Cited by 166
Stator winding turn-fault detection for closed-loop induction motor drives
Tallam, R. M., Habetler, T. G., & Harley, R. G. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.811784 · Cited by 163
Cruz, S. M. A., & Cardoso, A. J. M. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847975 · Cited by 158
Cheng, S., Zhang, P., & Habetler, T. G. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2064276 · Cited by 153
Pons-Llinares, J., Daviu, J. A. A., Riera‐Guasp, M., Pineda‐Sanchez, M., & Climente-Alarcón, V. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2081955 · Cited by 142
Low Order PWM Inverter Harmonics Contributions to the Inverter-Fed Induction Machine Fault Diagnosis
Akin, B., Orguner, U., Toliyat, H. A., & Rayner, M. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.911954 · Cited by 142
Briz, F., Degner, M. W., Zamarrón, A., & Guerrero, J. M. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.813746 · Cited by 132
Analytical Prediction of the Short-Circuit Current in Fault-Tolerant Permanent-Magnet Machines
Sun, Z., Wang, J., Howe, D., & Jewell, G. W. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2005019 · Cited by 121
A Simple Real-Time Fault Signature Monitoring Tool for Motor-Drive-Embedded Fault Diagnosis Systems
Akin, B., Choi, S., Orguner, U., & Toliyat, H. A. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2051936 · Cited by 113
An on-line method to detect incipient failure of turn insulation in random-wound motors
Sottile, J., & Kohler, J. L. (1993) · IEEE Transactions on Energy Conversion · doi:10.1109/60.260992 · Cited by 112
Fault Analysis and Parameter Identification of Permanent-Magnet Motors by the Finite-Element Method
Vaseghi, B., Takorabet, N., & Meibody‐Tabar, F. (2009) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2009.2022156 · Cited by 106
Awadallah, M. A., Morcos, M. M., Gopalakrishnan, S., & Nehl, T. W. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847976 · Cited by 105
Neti, P., & Nandi, S. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2018905 · Cited by 105
Physical modeling of PM synchronous motors for integrated coupling with Machine drives
Mohammed, O. A., Liu, S., & Liu, Z. (2005) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2005.846122 · Cited by 99
Self-citationMohammed, O. A., Liu, Z., Liu, S., & Abed, N. Y. (2007) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2006.892301 · Cited by 97
Self-citationOnline condition monitoring of induction motors
Trutt, F. C., Sottile, J., & Kohler, J. L. (2002) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2002.804758 · Cited by 91
An On-Line Stator Turn Fault Detection Method for Interior PM Synchronous Motor Drives
Lee, Y., & Habetler, T. G. (2007) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apex.2007.357610 · Cited by 60
Mohammed, O. A., Liu, S., & Liu, Z. (2006) · Digest of the Fifth Biennial IEEE Conference on Electromagnetic Field Computation · doi:10.1109/cefc-06.2006.1632949 · Cited by 59
Self-citationKallesøe, C. S., Izadi‐Zamanabadi, R., Vadstrup, P., & Rasmussen, H. (2007) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2007.900494 · Cited by 55
Inverter statistics for online detection of stator asymmetries in inverter-fed induction motors
Wolbank, T. M., Loparo, K. A., & Wohrnschimmel, R. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.814576 · Cited by 42
Winding turn-to-turn faults in permanent magnet synchronous machine drives
Gerada, C., Bradley, K., & Sumner, M. (2005) · doi:10.1109/ias.2005.1518481 · Cited by 41
Ding, X., Bhattacharya, M., & Mi, C. C. (2010) · Journal of Asian Electric Vehicles · doi:10.4130/jaev.8.1337 · Cited by 36
Fault detection of a five-phase Permanent-Magnet machine
Bianchini, C., Fornasiero, E., Matzen, T. N., Bianchi, N., & Bellini, A. (2008) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2008.4758125 · Cited by 31
Inter-turn short circuit fault detection of wound rotor induction machines using Bispectral analysis
Yazidi, A., Henao, H., Capolino, G., Bétin, F., & Capocchi, L. (2010) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2010.5618128 · Cited by 21
Inter-turn fault modeling of a variable speed pm wind generator using physics-based approach
Sarikhani, A., & Mohammed, O. A. (2011) · IEEE International Electric Machines & Drives Conference (IEMDC) · doi:10.1109/iemdc.2011.5994884 · Cited by 16
Self-citationKhoobroo, A., & Fahimi, B. (2009) · IEEE International Electric Machines & Drives Conference (IEMDC) · doi:10.1109/iemdc.2009.5075279 · Cited by 13
Fault Detection in a Current Controlled PM Drive Using Back-EMF Estimation and Residual Analysis
Leboeuf, N., Boileau, T., Nahid‐Mobarakeh, B., & Meibody‐Tabar, F. (2010) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.2010.5616894 · Cited by 8
Research works printed but not linked: 2
- xue, 2009, Linear Feedback Control Analysis and Design with Matlab, 92
- 10.1109/41.873206 · DOI · Paper page
Cited by
Riera-Guasp, M., Antonino-Daviu, J. A., & Capolino, G.-A. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2375853 · Cited by 573
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“[81] BEMF Residual analysis FI based on the difference between the estimated and reference BEMF EV, ON, TC, RL, RS The estimation of the BEMF is necessary”
MethodInfluentialHang, J., Zhang, J., Cheng, M., & Huang, J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2388493 · Cited by 218
Zafarani, M., Bostanci, E., Qi, Y., Goktas, T., & Akin, B. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2811538 · Cited by 208
A Model-Based Strategy for Interturn Short-Circuit Fault Diagnosis in PMSM
Mazzoletti, M. A., Bossio, G. R., De Angelo, C. H., & Espinoza-Trejo, D. R. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2688973 · Cited by 214
Metadata
- Authors
- Sarikhani, A., & Mohammed, O. A.
- Affiliations
- Florida International University (US)
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2013-08
- Volume
- 60
- Issue
- 8
- Pages
- 3472-3484
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2080850924
- Cited by
- 177
- References
- 41
- Citations by year
- 2026: 3 · 2025: 16 · 2024: 14 · 2023: 16 · 2022: 12 · 2021: 13 · 2020: 14 · 2019: 14 · 2018: 18 · 2017: 9 · 2016: 14 · 2015: 14 · 2014: 15 · 2013: 5
- FWCI
- 6.95
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Industrial Electronics (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Keywords
- permanent magnet synchronous motor, back electromotive force estimation, open-loop estimation, thermal modeling, magnetic saturation, estimator stability, fault signatures, dynamic eccentricity, harmonic loading
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.