Inter-Turn Fault Detection in PM Synchronous Machines by Physics-Based Back Electromotive Force Estimation
The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
In this paper, the inter-turn short circuit fault detection in permanent magnet synchronous machines (PMSM) using an open-loop physics-based back electromotive force (EMF) estimator is presented. The back EMF estimator is designed based upon a current mode tracking scheme. The thermal and saturation aspects of the machine are considered in the design of the estimator. The design procedure and stability criteria of the estimator are presented in detail. The fault detection is carried out based on the difference between the estimated back EMF and a reference back EMF. A 0.8 (kW) PMSM is studied experimentally as well as numerically under different inter-turn fault and operational contingencies. The numerical modeling is accomplished by a finite-element-based model coupled with the thermal network and polluted with inter-turn fault. The acceptable agreement between the simulated and experimental result validates the modeling process. The back EMF estimator fault detection system is led to discriminative inter-turn fault signatures in a fraction of second for wide speed range even in the presence of harmonic loads and dynamic eccentricities.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
A review of induction motors signature analysis as a medium for faults detection
El Hachemi Benbouzid, M. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873206 · Cited by 1,602
EL-Refaie, A. M. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2030211 · Cited by 1,373 · cited 1×
“The winding’s coils are physically separated, and therefore the shorted turns contact is limited to faulty coil [2].”
BackgroundRecent Advances in Modeling and Online Detection of Stator Interturn Faults in Electrical Motors
Gandhi, A., Corrigan, T., & Parsa, L. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2089937 · Cited by 544 · cited 4×
“In recent literature [7, 20]–[28], the extraction of fault features from different signals in both induction and PM machines is typically satisfied.”
BackgroundInfluentialCruz, S. M. A., & Cardoso, A. J. M. (2001) · IEEE Transactions on Industry Applications · doi:10.1109/28.952496 · Cited by 464
Static-, Dynamic-, and Mixed-Eccentricity Fault Diagnoses in Permanent-Magnet Synchronous Motors
Ebrahimi, B. M., Faiz, J., & Roshtkhari, M. J. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2029577 · Cited by 386 · cited 1×
“the accuracy of most frequency analyses-based methods [16],”
Henao, H., Demian, C., & Capolino, G.-A. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.816531 · Cited by 361 · cited 1×
“However, redundancy in fault detection systems by adding search coil, [21], the need for additional measurement system [22], underestimation of fault and nonsinusoidal armature flux linkage harmonics as well as the adverse effect of unbalance in the supply voltage [23], underestimation of non-stationary behavior of fa…”
BackgroundA new approach to on-line turn fault detection in AC motors
Kliman, G. B., Premerlani, W. J., Koegl, R. A., & Hoeweler, D. (2002) · IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting · doi:10.1109/ias.1996.557113 · Cited by 303
Linear Feedback Control - Analysis and Design with MATLAB (by Dingyu Xue et al; 2007) [Bookshelf]
(2009) · IEEE Control Systems · doi:10.1109/mcs.2008.930839 · Cited by 291
Cruz, S. M. A., & Marques Cardoso, A. J. (2002) · Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129) · doi:10.1109/ias.2000.881141 · Cited by 258 · cited 1×
“Most of the techniques deliberate inter-turn fault studies in utility-driven motor applications and only a few turn fault detection methods for motor-drive applications [11], [13].”
BackgroundLee, S. B., Tallam, R. M., & Habetler, T. G. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.810848 · Cited by 248
Research works printed but not linked: 2
- xue, 2009, Linear Feedback Control Analysis and Design with Matlab, 92
- 10.1109/41.873206 · DOI · Paper page
Cited by
Riera-Guasp, M., Antonino-Daviu, J. A., & Capolino, G.-A. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2375853 · Cited by 573
“Reference [70] introduces an FD”
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“[81] BEMF Residual analysis FI based on the difference between the estimated and reference BEMF EV, ON, TC, RL, RS The estimation of the BEMF is necessary”
MethodInfluentialHang, J., Zhang, J., Cheng, M., & Huang, J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2388493 · Cited by 218
“[11], high-frequency signal injection [12], searching coil [13], [14], parameter estimation [15], [16], electromagnetic torque [17], stray flux [18], q-axis current analysis [19], and machine current signature analysis (MCSA) [20], [21].”
Zafarani, M., Bostanci, E., Qi, Y., Goktas, T., & Akin, B. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2811538 · Cited by 208
“introduced by comparing the estimated and reference back EMF to detect ITSC in PMSMs (see [30] and [31]).”
MethodA Model-Based Strategy for Interturn Short-Circuit Fault Diagnosis in PMSM
Mazzoletti, M. A., Bossio, G. R., De Angelo, C. H., & Espinoza-Trejo, D. R. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2688973 · Cited by 214
Faiz, J., & Mazaheri-Tehrani, E. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2608950 · Cited by 207
“However, these methods need longer computational time compared with other data-based models [21].”
Choi, S., Haque, M. S., Tarek, M. T. B., Mulpuri, V., Duan, Y., Das, S., Garg, V., Ionel, D. M., Masrur, M. A., Mirafzal, B., et al. (2018) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2018.2819627 · Cited by 192
“estimation [139] while differentiating SITF from other types”
BackgroundHealth monitoring and prognosis of electric vehicle motor using intelligent‐digital twin
Venkatesan, S., Manickavasagam, K., Tengenkai, N., & Vijayalakshmi, N. (2019) · IET Electric Power Applications · doi:10.1049/iet-epa.2018.5732 · Cited by 183
“Spectral analysis of stator current is used to monitor bearing lubrication [19].”
MethodPark, J.-K., & Hur, J. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2499162 · Cited by 152
“In [18], the authors present an inter-turn short-circuit fault detection method for PM synchronous motors (PMSMs) using an open-loop physics-based back electromotive force (BEMF) estimator.”
MethodAn Early Stage Interturn Fault Diagnosis of PMSMs by Using Negative-Sequence Components
Jeong, H., Moon, S., & Kim, S. W. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2677355 · Cited by 141
“First of all, previous studies focused only on the verifications of their proposed methods for high number of short-circuited turns or low fault resistance conditions [23]–[26].”
BackgroundMethodA Comprehensive Analysis of Short-Circuit Current Behavior in PMSM Interturn Short-Circuit Faults
Qi, Y., Bostanci, E., Gurusamy, V., & Akin, B. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2809668 · Cited by 128
“Due to the high short-circuit currents, the thermal effect becomes a critical factor, thus a transient thermal model of interturn short-circuit machine is proposed in [12].”
BackgroundSeverity Estimation of Interturn Short Circuit Fault for PMSM
Yuan, Q., Bostancı, E., Zafarani, M., & Akin, B. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2879281 · Cited by 116
“signatures are directly related to the number of shorted turns [3], [10]–[14], [16], [19]–[21].”
BackgroundMethodDu, B., Wu, S., Han, S., & Cui, S. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2496900 · Cited by 105
“In [18], an observer based on a closed-loop control was designed to estimate the back EMF.”
BackgroundMethodMitigation of Turn-to-Turn Faults in Fault Tolerant Permanent Magnet Synchronous Motors
Cintron-Rivera, J. G., Foster, S. N., & Strangas, E. G. (2015) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2014.2360813 · Cited by 104
“In PMSMs designed with single-layer fractional slot concentrated windings (FSCW), phases do not share slots; hence, the phase-to-phase mutual inductances are dramatically reduced and the phases are physically isolated [14].”
BackgroundHasanzadeh, A., Edrington, C. S., Stroupe, N., & Bevis, T. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2279128 · Cited by 96
Comprehensive review on inter‐turn fault indexes in permanent magnet motors
Faiz, J., Nejadi‐Koti, H., & Valipour, Z. (2017) · IET Electric Power Applications · doi:10.1049/iet-epa.2016.0196 · Cited by 86
Geng, W., Zhang, Z., Jiang, K., & Yang-guang, Y. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2348936 · Cited by 86
“However, the reluctance part has no contribution to output power, and the field adjustment is unidirectional [19], [20].”
BackgroundChoi, S., Pazouki, E., Baek, J., & Bahrami, H. R. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2361112 · Cited by 85
“In [26], open-loop physics-based back electromotive force signal is measured for the diagnosis of interturn phase winding”
MethodNussbaumer, P., Vogelsberger, M. A., & Wolbank, T. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2361114 · Cited by 90
Nadarajan, S., Panda, S. K., Bhangu, B., & Gupta, A. K. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2370931 · Cited by 89
“This high fault current increases the slot leakage flux and can cause the localized iron saturation around the slots carrying shorted turns [16], as shown in Fig.”
BackgroundAnalysis of Vertical Strip Wound Fault-Tolerant Permanent Magnet Synchronous Machines
Arumugam, P., Hamiti, T., Brunson, C., & Gerada, C. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2259777 · Cited by 72
“P ERMANENT magnet synchronous machines (PMSMs) [1]–[4] are increasingly being used in safety critical applications such as in aircraft and other transportation systems.”
BackgroundUllah, Z., & Hur, J. (2018) · Energies · doi:10.3390/en11123309 · Cited by 76
“However, compared to other data-based methods, these techniques are still computationally complex [28].”
MethodResultBhuiyan, E. A., Akhand, M. M. A., Das, S. K., Ali, M. F., Tasneem, Z., Islam, M. R., Saha, D. K., Badal, F. R., Ahamed, M. H., & Moyeen, S. I. (2020) · International Journal of Automation and Computing · doi:10.1007/s11633-020-1250-3 · Cited by 68
Huang, W., Du, B., Li, T., Sun, Y., Cheng, Y. Z., & Cui, S. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3213512 · Cited by 70
“The second method, called the model-based approach, often requires the establishment of a high-precision mathematical model and machine parameters by state observer [14], [15], Kalman filter [16], [17], [18], and so on.”
MethodLiu, X., Liu, C., & Pong, P. W. T. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2816931 · Cited by 57
“early diagnostic purposes [4], [5].”
Xiang, D., Li, H., Yan, H., Yan, Z., Zhao, N., & Liu, B. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3049809 · Cited by 53
Analysis and Detection of Inter-Turn Short-Circuit Fault Through Extended Self-Commissioning
Yuan, Q., Zafarani, M., Akin, B., & Fedigan, S. E. (2016) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2626264 · Cited by 51
“Similar to MCSA, the back-electromotive force (emf) is also analyzed in frequency domain with searching coils [13] and back-emf estimators in [14] and [15].”
MethodDetection and Evaluation of the Interturn Short Circuit Fault in a BLDC-Based Hub Motor
Wang, H., Wang, J., Wang, X., Lu, S., Hu, C., & Cao, W. (2022) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3167167 · Cited by 52
Jiang, Y., Zhang, Z., Jiang, W., Geng, W., & Huang, J. (2018) · IET Electric Power Applications · doi:10.1049/iet-epa.2017.0754 · Cited by 45
Zhang, X., Hu, Y., Gong, C., Deng, J., & Wang, G. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3285531 · Cited by 48
“As for the disadvantage mentioned in [25], it is necessary to perform calculations and build a new EMF estimator for each machine before using the method in the actual EV motor.”
MethodFault-Tolerant Capability of Deadbeat-Direct Torque and Flux Control for Three-Phase PMSM Drives
Scarcella, G., Scelba, G., Pulvirenti, M., & Lorenz, R. D. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2017.2743070 · Cited by 47
“as an open/short circuit of the stator windings [9], [10].”
BackgroundShi, Y., Wang, J., & Wang, B. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.2988224 · Cited by 44
“An LP thermal network dividing the fault phase into healthy and fault turns is presented in [11] in order to estimate the resistance for interturn fault detection in a permanent magnet synchronous machine.”
MethodDiagnosis of stator winding short-circuit faults in an interior permanent magnet synchronous machine
He, J., Somogyi, C., Strandt, A., & Demerdash, N. A. O. (2014) · 2014 IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2014.6953825 · Cited by 39
“A few diagnostic methods for stator short-circuit faults have been presented in the literature [5-23], and the most popular one among them is the motor current spectrum analysis (MCSA) [5], in which time-domain phase currents of electric machines are transformed into frequency domain spectra and in such spectra certai…”
Review of intelligent fault diagnosis for permanent magnet synchronous motors in electric vehicles
Xu, X., Xue, Q., Zhang, N., Feng, J., & Wang, X. (2014) · Advances in Mechanical Engineering · doi:10.1177/1687814020944323 · Cited by 42
Peng, J., Zhou, J., Chen, J., Pi, D., Wu, J., Wang, H., & Ding, F. (2023) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2023.3339490 · Cited by 36
“Motor degradation studies have mostly been focused on winding insulations [45], [46], magnets [47], [48], and bearings [49], [50] involving complex models and specific parameters.”
BackgroundLeboeuf, N., Boileau, T., Nahid‐Mobarakeh, B., Takorabet, N., Meibody‐Tabar, F., & Clerc, G. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2387338 · Cited by 38
“methods presented in [25] and [26] can be also interesting as they are less dependent on other types of faults and include more representative models of the monitored drive.”
BackgroundStudy of IPMSM Interturn Faults Part II: Online Fault Parameter Estimation
Gu, B.-G. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2506640 · Cited by 35
“b) Negative-sequence/transfer impedance or unbalanced back-EMF [7], [8], [11], [12], [16], [23].”
BackgroundPietrzak, P., & Wolkiewicz, M. (2023) · Electronics · doi:10.3390/electronics12071543 · Cited by 33
Xu, Y., Zhang, Z., Jiang, Y., Huang, J., & Jiang, W. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2956399 · Cited by 34
“The impedance [7], torque [8], sequence voltage component [9], and voltage changes [10] have been used as indicators to detect the turn-to-turn SC faults.”
MethodAnalysis and Monitoring Method for Inter-Turn Short-Circuit Fault for PMSM
Liu, C., Xiao, L., Zou, J., Xu, Y., & Li, S. (2023) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2023.3294704 · Cited by 32
“Besides, other signatures, such as the variation of back electromotive force (back EMF), voltage, and stator winding impedance, are also taken as signatures to monitor ITSC fault [12], [13], [14], and current injection method is also employed to monitor ITSC fault of PMSM [15].”
MethodKo, Y., Lee, Y., Oh, J., Park, J., Chang, H., & Kim, N. (2024) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2024.111377 · Cited by 33
Mechanism-Based Fault Diagnosis Deep Learning Method for Permanent Magnet Synchronous Motor
Li, L., Liao, S., Zou, B., & Liu, J. (2024) · Sensors · doi:10.3390/s24196349 · Cited by 33
“Inter-turn short-circuit faults account for 21% of all faults [5,6], while permanent magnet demagnetization faults represent 26% of all faults [7,8].”
BackgroundSen, B., Wang, J., & Lazari, P. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2491884 · Cited by 32
“In [10] and [27], an inductance-based model was proposed for interturn fault detection in PM synchronous machines.”
MethodHe, Y., Zhang, Y., Xu, M., Wang, X., & Xiong, J. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2907450 · Cited by 33
“Eγm , γ EMF amplitude of γth harmonic, harmonic order.”
MethodInfluentialA Torque Angle-Based Fault Detection and Identification Technique for IPMSM
Ullah, Z., Lee, S.-T., & Hur, J. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2019.2947401 · Cited by 34
“Other methods for ITSF detection are based on negative sequence in stator current [12], input impedance [13], search coil [14], injecting high-frequency signal [15], machine parameter estimation [16], and electromagnetic torque [17].”
Methodvan der Geest, M., Polinder, H., Ferreira, J. A., Veltman, A., Wolmarans, J. J., & Tsiara, N. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2402641 · Cited by 32
“yet another approach but requires extensive knowledge about the machine parameters [7], [21], although Kalman filtering can improve performance [22].”
BackgroundMethodFault Detection and Condition Monitoring of PMSGs in Offshore Wind Turbines
Freire, N. M. A., & Cardoso, A. J. M. (2021) · Machines · doi:10.3390/machines9110260 · Cited by 39
“An openloop physics-based estimator enables the comparison between estimated and reference back-EMF in [110], and the difference is used for detecting interturn faults.”
MethodImproved ZSVC‐based fault detection technique for incipient stage inter‐turn fault in PMSM
Fang, J., Sun, Y., Wang, Y., Wei, B., & Hang, J. (2019) · IET Electric Power Applications · doi:10.1049/iet-epa.2019.0016 · Cited by 30
Inter-Turn Fault Diagnosis and Control for Five-Phase PMSMs by Disturbance Observer
Chen, Q., Han, X., Liu, G., Zhao, W., & Shi, H. T. H. (2024) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2024.3374364 · Cited by 31
“Most of the model-based methods simulate the normal motor model in different coordinate systems under fault conditions to obtain residual current, voltage, or back electromotive force (EMF) [13], [14], [15] to realize the detection of inter-turn faults.”
MethodTowards Digital Twin Modeling and Applications for Permanent Magnet Synchronous Motors
Lukman, G. F., & Lee, C. (2025) · Energies · doi:10.3390/en18040956 · Cited by 34
Niu, F., Wei, F., Huang, S., Wu, L., Zhang, J., Huang, X., & Fang, Y. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3273897 · Cited by 29
“Several methods have been proposed to deal with susceptible signals in permanent magnet synchronous motors (PMSMs), such as state observer and generalized integrator of back electromotive force (EMF) [22], [23], fault detection indicators based on artificial intelligence [24], [25], [26], [27], and high-frequency sign…”
BackgroundJiang, Y., Ji, B., Zhang, J., Yan, J., & Li, W. (2024) · World Electric Vehicle Journal · doi:10.3390/wevj15040165 · Cited by 30
“An open-loop BEMF estimation method based on physical principle is proposed [26], which is suitable for any anti-electromotive force waveform of PMSMs.”
MethodXu, J., Tian, X., Jin, W., & Guo, H. H. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3238167 · Cited by 28
“For the impedance analysis of the FTPMSM, using (12) with the back-EMF to zero, the admittance can be written as Ψ(jω) = iah(jω) UAB(jω) = 1 Rs + jωLs + 1 rf μ2 + ( 1 μ − 1 ) Rs = rf + μRs + jωμ 2Ls (Rs + jωLs) (rf + μ (1− μ)Rs) .”
MethodInfluentialBlánquez, F. R., Platero, C. A., Rebollo, E., & Blázquez, F. C. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2497214 · Cited by 28
“receiving attention as well [29], and important studies related to permanent magnet synchronous machines [30]–[32], or rotor eccentricity [33]–[35], have been lately published.”
BackgroundNorniella, J. G., Cano, J. M., Orcajo, G. A., Rojas, C. H., Pedrayes, F., Cabanas, M. F., & Melero, M. G. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2334651 · Cited by 27
Ge, Y., Song, B., Pei, Y., Mollet, Y., & Gyselinck, J. J. C. (2018) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2018.2878343 · Cited by 26
“In a three-phase machine, the faulty phase has a different number of turns compared to the healthy phases, thus produces asymmetrical EMF, voltage, current, etc [6]–[8].”
BackgroundXu, Y., Wang, Y., & Zou, J. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2021.3125653 · Cited by 25
“In [13] and [14], the residual current and the residual back EMF are used to detect the ITSC fault and measure the severity of the fault.”
MethodFoster, S. N., Cintron-Rivera, J. G., & Strangas, E. G. (2015) · Electric Power Systems Research · doi:10.1016/j.epsr.2015.10.021 · Cited by 25
Faiz, J., Nejadi-Koti, H., & Exiri, A. H. (2017) · Electric Power Components and Systems · doi:10.1080/15325008.2017.1293196 · Cited by 20
Inter-Turn Short Circuit Fault Diagnosis of PMSM
Chen, X., Qin, P., Chen, Y., Zhao, J., Li, W., Mao, Y., & Zhao, T. (2022) · Electronics · doi:10.3390/electronics11101576 · Cited by 24
Faiz, J., Exiri, A. H., & Nejadi-Koti, H. (2016) · IEEE International Conference on Compatibility, Power Electronics and Power Engineering · doi:10.1109/cpe.2016.7544197 · Cited by 21
“INTRODUCTION This template, Different faults can change the performance of the healthy permanent magnet synchronous machines (PMSM) [1-4].”
BackgroundIm, S.-H., & Gu, B.-G. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2941146 · Cited by 19
“Through a physics-based development of an open loop back electromotive force (BEMF) estimator, ITF was detected from the unbalanced BEMF [8], and the phase impedance of the motor was used for ITF detection [9], [10].”
MethodHu, J., Wang, H., & Li, Y. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3314652 · Cited by 18
“In addition, the fault indicators were generated by zero-sequence component [24], negative sequence component [25], [26], [27], electromotive force [28], [29], [30] and other signals such as the cost function in model predictive control [31].”
MethodHe, Y., Wang, F.-L., Tang, G., & Ke, M.-Q. (2016) · Electric Power Components and Systems · doi:10.1080/15325008.2016.1247387 · Cited by 19
“It is found that the variation characteristics of the winding inductance and the stator current can be adopted to diagnose this fault [11], while the electromotive force (EMF) variation characteristics can be used to calculate the shorted degree and the shorted location [12].”
BackgroundAlvarez‐Gonzalez, F., Griffo, A., & Wang, B. (2018) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2018.8591661 · Cited by 17
“In [16] back-EMF estimation is combined with a finite element (FE) model coupled with a thermal network.”
MethodPWM Ripple Currents Based Turn Fault Detection for Multiphase Permanent Magnet Machines
Hu, R., Wang, J., Sen, B., Mills, A. R., Chong, E., & Sun, Z. (2016) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2642193 · Cited by 19
“Residual current, voltage, or back-electromotive force (EMF) are also utilized to detect turn fault [22]–[24], where an accurate model is used for prediction and the residual between the prediction and measurement is used for fault detection.”
MethodFaiz, J., Bazrafshan, M. A., & Tabarniarami, Z. (2024) · IET Electric Power Applications · doi:10.1049/elp2.12519 · Cited by 20
Fireţeanu, V., Lombard, P., & Constantin, A.-I. (2014) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2014.6960389 · Cited by 16
Navarro-Navarro, Á., Ruiz-Sarrio, J. E., Biot-Monterde, V., Daviu, J. A. A., Becker, V., & Urschel, S. (2023) · Machines · doi:10.3390/machines11020288 · Cited by 17
Palavicino, P. C., & Sarlioglu, B. (2023) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2023.3268996 · Cited by 16
“Methods for ISC detection include current waveform frequency analysis [11], high-frequency signal injection [12], [13], data-driven strategies [14], [15], sequence components [16], [17], [18], and observer-based [19], [20], [21], [22], [23], [24].”
MethodWu, Y., Zhang, J., Xu, Z., Wang, S., & Fu, H. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3415792 · Cited by 17
“In [8], the ISF is detected by the back electromotive force estimator.”
MethodYang, J. W., Dai, Z., & Zhang, Z. (2020) · Microelectronics Reliability · doi:10.1016/j.microrel.2020.113778 · Cited by 15
Interturn Short-Circuit Fault Detection of a Five-Phase Permanent Magnet Synchronous Motor
Yang, Z., & Chen, Y. (2021) · Energies · doi:10.3390/en14020434 · Cited by 15
“proposed a method that uses an open-loop physics-based back electromotive force (EMF) estimator to detect an ISCF under steady-state operations [25].”
MethodAnalytical optimal currents for multiphase PMSMs under fault conditions and saturation
Nguyen, N. K., Flieller, D., Kestelyn, X., Moraes, T. J. D. S., & Semail, E. (2014) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2014.7048968 · Cited by 18
“Fault detection and control reconfiguration of the drive in case of open-circuit faults have been extensively studied in the past years [5-8].”
Liu, Y., Huang, S. H., Liao, W., Wang, S., Tang, H., Liang, G., Luo, D., Wu, X., & Huang, S. (2024) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2024.3449323 · Cited by 14
“Motor drive can cause different types of faults, including open-/short-circuits faults in the semiconductor devices and stator windings [20], [21].”
BackgroundWang, L., Aleksandrov, S. R., Tang, Y., Paulides, J. J. H., & Lomonova, E. A. (2017) · IET Electric Power Applications · doi:10.1049/iet-epa.2016.0864 · Cited by 14
Huang, S., Bi, Z., Sun, Z., Aggarwal, A., Huang, X., Wu, L., & Niu, F. (2022) · Energies · doi:10.3390/en15093248 · Cited by 14
Shi, Y., Wang, J., Hu, R., & Wang, B. (2020) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2020.3014274 · Cited by 14
“Based on this understanding, most fault detection and mitigation measures reported in the literature are tested and validated under the ideal one turn or a few turns SC [5], [6].”
BackgroundBlánquez, F. R., Aranda, M., Rebollo, E., Blázquez, F. C., & Platero, C. A. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2336612 · Cited by 17
“machines [34]–[36] or rotor eccentricity [37], [38] have been recently published, in the topic of fault detection and location in the field winding, there are not many contributions [39]–”
BackgroundA Novel Fault Diagnosis Technique for IPMSM Using Voltage Angle
Ullah, Z., Lee, S.-T., & Hur, J. (2018) · 2018 IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2018.8557375 · Cited by 13
“Many techniques have been proposed to diagnose ITSF, which are based on partial discharge [4], voltage signal [5], stator current dq-axis or Park’s vector [6], [7],negative sequence in stator current [8], the components of the sequence impedance matrix [9], searching coil [10], [11], injecting high frequency signal [1…”
BackgroundLi, H., Yin, X., He, W., Feng, Z., & Cao, Y. (2023) · IEEE Access · doi:10.1109/access.2023.3309409 · Cited by 13
“proposed an open-loop physics-based inverse electric potential estimator for inter-turn short-circuit fault detection in the permanent magnet synchronous motor [5].”
BackgroundChen, L., Wang, J., & Sun, Z. (2019) · The Journal of Engineering · doi:10.1049/joe.2018.8053 · Cited by 13
“ψi = f i(id, iq, i f , θ), i = a, b, c, f (4)”
Sensorless Control of Heat Inflow to a Thermal Display Using a Heat Inflow Observer
Morimitsu, H., & Katsura, S. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2384474 · Cited by 12
“1) The model of the thermal system is derived from a thermal network [23]–[25] considering a practical situation, whereas [22] focused on the generalized form and modeled the system by using the distributed parameter systems.”
BackgroundMethodUllah, Z., Kim, K., Park, J.-K., & Hur, J. (2015) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2015.7309711 · Cited by 11
Tao, Y.-H., Wang, X., Zhang, L., Bao, X., Xue, H., Yue, H., Feng, H., & Yang, D. (2025) · Machines · doi:10.3390/machines13080711 · Cited by 15
Detection of inter-turn short-circuit at start-up of induction machine based on torque analysis
Pietrowski, W., & Górny, K. (2017) · Open Physics · doi:10.1515/phys-2017-0101 · Cited by 10
“This method is more fully described in [7].”
MethodSuti, A., Rito, G. D., & Galatolo, R. (2022) · Aerospace · doi:10.3390/aerospace9080401 · Cited by 10
“The FDI algorithm proposed in [23], implements an estimator of back electromotive force and detects the ITSC by comparing the estimates to a reference model.”
MethodQiu, H., Yu, W., Yuan, S., Tang, B., & Yang, C. (2017) · COMPEL The International Journal for Computation and Mathematics in Electrical and Electronic Engineering · doi:10.1108/compel-09-2016-0380 · Cited by 10
Yang, Y., Chen, Y., & Hao, W. (2020) · IET Electric Power Applications · doi:10.1049/elp2.12011 · Cited by 9
“Since the back EMF of the short‐circuit phase will decrease, it can be used as a fault indicator.”
MethodInfluentialLei, Z., Xu, P., Wu, X., Yuan, K., Wu, T., Yu, X., Yang, D., Rong, F., & Huang, S. (2025) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2025.3604179 · Cited by 9
Reactive power characteristics and vibration properties under SISC in synchronous condensers
Jiang, M., Ma, H., Zhang, Y., Chen, X., & Zhao, X. (2021) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2021.107318 · Cited by 9
Variable Heat Disturbance Observer for Control of Peltier Device
Osawa, Y., & Katsura, S. (2019) · IEEJ Journal of Industry Applications · doi:10.1541/ieejjia.8.185 · Cited by 12
Particle Filtering Based Remaining Useful Life Prediction for Electromagnetic Coil Insulation
Guo, H., Xu, A., Wang, K., Sun, Y., Han, X., Hong, S. H., & Yu, M. (2021) · Sensors · doi:10.3390/s21020473 · Cited by 9
Fault tolerant capability of deadbeat — Direct torque and flux control for three-phase PMSM drives
Pulvirenti, M., Scarcella, G., Scelba, G., & Lorenz, R. D. (2016) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2016.7855113 · Cited by 9
“as an open/short circuit of the stator windings [9], [10].”
BackgroundXin, P., Ge, B., Tao, D., & Lv, P. (2021) · Journal of Electrical Engineering and Technology · doi:10.1007/s42835-021-00723-7 · Cited by 8
Bouzid, M. B. K., Bahloul, I., & Khil, S. K. E. (2021) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/sdemped51010.2021.9605551 · Cited by 9
Palavicino, P. C., Lee, W., & Sarlioglu, B. (2022) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2022.3203032 · Cited by 8
“One option to classify physics-based techniques consist of observer-based [13], [14], [15], [16], [17], [18] Voltage or back EMF-tracking [8], [19], [20], [21], and parameter estimation [22], [23].”
BackgroundMethodInfluentialA Fault Severity Index for Stator Winding Faults Detection in Vector Controlled PM Synchronous Motor
Hadef, M., Djerdir, A., Ikhlef, N., Mékidèche, M. R., & N’Diaye, A. (2015) · Journal of Electrical Engineering and Technology · doi:10.5370/jeet.2015.10.6.2326 · Cited by 8
Palavicino, P. C., Gurleyen, H., Wu, Y., & Sarlioglu, B. (2016) · IEEE Transportation Electrification Conference and Expo · doi:10.1109/itec.2016.7520251 · Cited by 7
“In reference [6], a technique using finite element is proposed.”
MethodShi, Y., Wang, J., & Wang, B. (2021) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2021.3127856 · Cited by 7
“Some papers have considered the thermal analysis under fault conditions by lumped parameter thermal models and the finite-element analysis [6], [7] for obtaining the worst fault scenario.”
Method
Metadata
- Authors
- Sarikhani, A., & Mohammed, O. A.
- Affiliations
- Florida International University (US)
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2013-08
- Volume
- 60
- Issue
- 8
- Pages
- 3472-3484
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2080850924
- Cited by
- 177
- References
- 41
- Citations by year
- 2026: 3 · 2025: 16 · 2024: 14 · 2023: 16 · 2022: 12 · 2021: 13 · 2020: 14 · 2019: 14 · 2018: 18 · 2017: 9 · 2016: 14 · 2015: 14 · 2014: 15 · 2013: 5
- FWCI
- 6.95
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Industrial Electronics (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Keywords
- permanent magnet synchronous motor, back electromotive force estimation, open-loop estimation, thermal modeling, magnetic saturation, estimator stability, fault signatures, dynamic eccentricity, harmonic loading
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.