The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
A Model-Based Strategy for Interturn Short-Circuit Fault Diagnosis in PMSM
Open accessAbstract
A model-based method for interturn short-circuit fault detection and isolation in permanent magnet synchronous machines (PMSMs) is proposed in this paper. The fault detection is realized based on a residual current vector (RCV) generated by the difference between the measured stator currents and the stator currents estimated by a state observer. In order to avoid false alarms due to possible undesired perturbations, the sequence decomposition of the RCV is performed by employing different reference-frames. Thus, the proposed RCV allows the correct detection of interturn short-circuit faults and quantification of the fault severity in any faulty stator-phase winding. Moreover, since the back-EMF generated by the magnets is proportional to the rotor shaft speed, the electrical angular speed is estimated through the stator voltages measurement, without using a speed sensor. Simulation results from the three-phase PMSM dynamic model that allows considering the interturn short-circuit fault in any stator phase-windings are presented. The proposed method is validated using a three-phase PMSM prototype with modified stator windings. The robustness and the reliability of the proposal was tested for several interturn fault conditions under transient conditions including different disturbances.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sarikhani, A., & Mohammed, O. A. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2222857 · Cited by 177
Haddad, R. Z., & Strangas, E. G. (2016) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2016.2558183 · Cited by 158
Obeid, N. H., Boileau, T., & Nahid-Mobarakeh, B. (2016) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2581760 · Cited by 52
Research works printed but not linked: 25
- 10.1109/TIE.2008.2007529 · DOI
- 10.1109/TEC.2010.2040083 · DOI · Paper page
- 10.1109/TIE.2008.2011580 · DOI · Paper page
- 10.1109/TIE.2014.2348934 · DOI
- 10.1109/TIE.2016.2535959 · DOI
- 10.1109/TIE.2009.2012468 · DOI · Paper page
- 10.1109/TIE.2010.2062480 · DOI · Paper page
- 10.1109/TPEL.2012.2222049 · DOI
- 10.1109/TPEL.2015.2496142 · DOI
- 10.1109/CDC.1997.649776 · doi:10.1109/cdc.1997.649776
- 10.1109/TIE.2016.2530046 · DOI
- 10.1002/9781118524336 · DOI · Paper page
- 10.1109/TIE.2008.2007527 · DOI · Paper page
- 10.1109/TIE.2010.2060463 · DOI · Paper page
- 10.1049/iet-pel.2012.0256 · DOI
- 10.1109/TIM.2010.2047662 · doi:10.1109/tim.2010.2047662
- duan, 0, A review of condition monitoring and fault diagnosis for permanent magnet machines, Proc IEEE Power Energy Soc Gen Meeting, 1
- 10.1109/TIE.2008.2004665 · DOI · Paper page
- 10.1109/TPEL.2015.2388493 · DOI · Paper page
- 10.1109/TMAG.2012.2230334 · doi:10.1109/tmag.2012.2230334
- 10.1109/TIE.2014.2387338 · DOI
- 10.1109/TIA.2002.1003411 · DOI · Paper page
- 10.1109/IAS.2015.7356845 · DOI
- 10.1109/RPIC.2015.7497159 · doi:10.1109/rpic.2015.7497159
- 10.1109/TIA.2011.2168929 · DOI · Paper page
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“A state observer for stator current estimation of PMSM is proposed in [192] for ITSC fault detection.”
MethodFaults and Diagnosis Methods of Permanent Magnet Synchronous Motors: A Review
Chen, Y., Liang, S., Li, W., Liang, H., & Wang, C. (2019) · Applied Sciences · doi:10.3390/app9102116 · Cited by 194
Chen, Z., Liang, D., Jia, S., Yang, L., & Yang, S. (2023) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2023.3255249 · Cited by 72
Bhuiyan, E. A., Akhand, M. M. A., Das, S. K., Ali, M. F., Tasneem, Z., Islam, M. R., Saha, D. K., Badal, F. R., Ahamed, M. H., & Moyeen, S. I. (2020) · International Journal of Automation and Computing · doi:10.1007/s11633-020-1250-3 · Cited by 68
Krzysztofiak, M., Skowron, M., & Orlowska-Kowalska, T. (2020) · Energies · doi:10.3390/en14010153 · Cited by 33
Metadata
- Authors
- Mazzoletti, M. A., Bossio, G. R., De Angelo, C. H., & Espinoza-Trejo, D. R.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2017-09
- Volume
- 64
- Issue
- 9
- Pages
- 7218-7228
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2602794282
- Cited by
- 214
- References
- 4
- FWCI
- 6.82
- Type
- journal article
- Language
- en
- Open access
- green
- Funders
- Consejo Nacional de Investigaciones Científicas y Técnicas, Argentina
- Universidad Nacional de Río Cuarto, Argentina
- Universidad Nacional de Misiones, Argentina
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Model-Based Strategy for Interturn Short-Circuit Fault Diagnosis in PMSM. https://app.cochat.ai/papers/10.1109/tie.2017.2688973
- The paper
- Mazzoletti, M. A., Bossio, G. R., De Angelo, C. H., & Espinoza-Trejo, D. R. (2017). A Model-Based Strategy for Interturn Short-Circuit Fault Diagnosis in PMSM. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2017.2688973
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.