The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Nonactive Power Loss Minimization in a Bidirectional Isolated DC–DC Converter for Distributed Power Systems
Abstract
Originated from analyzing nonactive power loss, a novel optimization method and modulation solution for bidirectional isolated dual-active-bridge (DAB) dc-dc converters are proposed in order to achieve high efficiency in a wide operating range. A comprehensive nonactive power loss model is developed, including both the nonactive components delivered back to the source and from the load. This paper points out that when the minimum nonactive power loss is achieved, zero-voltage soft switching can be naturally fulfilled. The optimal phase-shift pair obtained by the proposed method can keep low values of both root mean square (RMS) current and circulating power. Rather than using ideal power flow analysis, the nonactive power loss model directly embodies practical nonideal factors, including device voltage drops. Based on the analysis, an extended dual phase shift is proposed, and different operation cases are analyzed with comparison of performance indices. Experimental tests verify the theoretical analysis and show effectiveness of the proposed approach to achieve nonactive power loss minimization and efficiency improvement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zhao, B., Yu, Q., & Sun, W. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2180928 · Cited by 932
Krismer, F., & Kolar, J. W. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2025284 · Cited by 470
Cited by
Extreme Fast Charging of Electric Vehicles: A Technology Overview
Tu, H., Feng, H., Srdic, S., & Lukic, S. (2019) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2019.2958709 · Cited by 898
Hou, N., & Li, Y. W. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2927930 · Cited by 553
Huang, J., Wang, Y., Li, Z., & Lei, W. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2543182 · Cited by 501
Khalid, M. R., Khan, I. A., Hameed, S., Asghar, M. S. J., & Ro, J. (2021) · IEEE Access · doi:10.1109/access.2021.3112189 · Cited by 353
Optimized Operation of Current-Fed Dual Active Bridge DC–DC Converter for PV Applications
Shi, Y., Li, R., Xue, Y., & Li, H. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2432093 · Cited by 298
Metadata
- Authors
- Wen, H., Xiao, W., & Su, B.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2014-12
- Volume
- 61
- Issue
- 12
- Pages
- 6822-6831
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2080347140
- Cited by
- 179
- References
- 2
- FWCI
- 8.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nonactive Power Loss Minimization in a Bidirectional Isolated DC–DC Converter for Distributed Power Systems. https://app.cochat.ai/papers/10.1109/tie.2014.2316229
- The paper
- Wen, H., Xiao, W., & Su, B. (2014). Nonactive Power Loss Minimization in a Bidirectional Isolated DC–DC Converter for Distributed Power Systems. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2014.2316229
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.