Comparative Study of Predictive and Resonant Controllers in Fault-Tolerant Five-Phase Induction Motor Drives
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
One of the most attractive features of multiphase machines is the fault-tolerant capability due to the higher number of phases. Different postfault control strategies based on hysteresis, proportional integral (PI)-resonant, and predictive techniques have been recently proposed. They all proved their capabilities to withstand fault situations and to preserve the fundamental component of the air-gap field, while achieving minimum losses, maximum torque per ampere, and reducing torque vibrations. Nonetheless, due to their recent introduction, no thorough study has yet appeared comparing the performance of these controllers. In this paper, two open-phase fault-tolerant control schemes are experimentally compared in a real five-phase induction machine. The controllers being compared are based on PI-resonant and predictive control techniques, respectively. The experiments include pre- and postfault situations. Obtained results show that both control methods offer nearly the same performance. When compared, predictive control provides faster control response and superior performance at low-speed operation but is found to be less resilient to fault detection delays and to have higher current ripple. Regarding the controller implementation, it is shown that the transition from prefault to postfault operation involves modeling the nonlinear effects observed when an open-phase fault occurs for the predictive controller and proper retuning of the PI trackers for the PI-resonant controller, to ensure postfault operation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
State of the Art of Finite Control Set Model Predictive Control in Power Electronics
Rodriguez, J., Kazmierkowski, M. P., Espinoza, J. R., Zanchetta, P., Abu-Rub, H., Young, H. A., & Rojas, C. A. (2013) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2012.2221469 · Cited by 1,802 · cited 1×
“Many contributions have been made in the last decade, both for three-phase [15], [16] and multiphase drives [17]–[21] operating in a healthy state.”
BackgroundMultiphase induction motor drives – a technology status review
Levi, E., Bojoi, R., Profumo, F., Toliyat, H. A., & Williamson, S. (2007) · IET Electric Power Applications · doi:10.1049/iet-epa:20060342 · Cited by 1,619 · cited 14×
“THE ability of multiphase machines to continue operating even in the presence of one or more open-phase faults is a distinctive feature in comparison to conventional threephase machines [1].”
BackgroundInfluentialChe, H. S., Duran, M. J., Levi, E., Jones, M., Hew, W.-P., & Rahim, N. A. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2293195 · Cited by 394 · cited 3×
“In any case, in none of these contributions [2]–[14], the transition from prefault to”
BackgroundMethodSelf-citationDisturbance-free operation of a multiphase current-regulated motor drive with an opened phase
Fu, J.-R., & Lipo, T. A. (1994) · IEEE Transactions on Industry Applications · doi:10.1109/28.315238 · Cited by 372
Disturbance free operation of a multiphase current regulated motor drive with an opened phase
Fu, J.-R., & Lipo, T. A. (2002) · Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting · doi:10.1109/ias.1993.298884 · Cited by 318 · cited 4×
“forms of the reference currents in the α-β subspace (given for the maximum current allowed for ML) are [5]”
BackgroundInfluentialFault-Tolerant Interior-Permanent-Magnet Machines for Hybrid Electric Vehicle Applications
Parsa, L., & Toliyat, H. A. (2007) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2007.896978 · Cited by 317 · cited 3×
“In any case, in none of these contributions [2]–[14], the transition from prefault to”
BackgroundFault-Tolerant Control of Five-Phase Permanent-Magnet Motors With Trapezoidal Back EMF
Dwari, S., & Parsa, L. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2045322 · Cited by 289 · cited 2×
“Moreover, depending on the set of x-y current references, different control criteria can be proposed, aiming at ensuring minimum drive derating [5], [6], reducing copper losses [5]–[7], limiting postfault torque ripple, or injecting third current harmonic for torque enhancement [8], [9].”
BackgroundΚαραμανάκος, Π., Geyer, T., Οικονόμου, Ν., Kieferndorf, F. D., & Manias, S. N. (2014) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2013.2290474 · Cited by 274
Guzman, H., Duran, M. J., Barrero, F., Bogado, B., & Toral, S. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2289882 · Cited by 258 · cited 5×
“The controller is based on an outer speed PI regulator and an inner fault-tolerant FCS-MPC controller [25], as shown in”
BackgroundMethodSelf-citationModeling and control of a multi-phase induction machine with structural unbalance
Zhao, Y., & Lipo, T. A. (1996) · IEEE Transactions on Energy Conversion · doi:10.1109/60.537028 · Cited by 216 · cited 1×
“This option has been followed in [6], [10], and [11] for five- and six-phase machines, respectively.”
Cited by
Recent Advances in the Design, Modeling, and Control of Multiphase Machines—Part I
Barrero, F., & Duran, M. J. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2447733 · Cited by 927
Self-citationRecent Advances in the Design, Modeling, and Control of Multiphase Machines—Part II
Duran, M. J., & Barrero, F. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2448211 · Cited by 658
Self-citationA Unified Analysis of the Fault Tolerance Capability in Six-Phase Induction Motor Drives
Munim, W. N. W. A., Duran, M. J., Che, H. S., Bermudez, M., Gonzalez-Prieto, I., & Rahim, N. A. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2632118 · Cited by 292
Self-citationMultiphase machines and drives - Revisited
Levi, E., Barrero, F., & Duran, M. J. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2493510 · Cited by 290
Self-citationOpen-Phase Fault-Tolerant Direct Torque Control Technique for Five-Phase Induction Motor Drives
Bermudez, M., Gonzalez-Prieto, I., Barrero, F., Guzman, H., Duran, M. J., & Kestelyn, X. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2610941 · Cited by 208
“the open-phase fault occurrence [10]–[12].”
BackgroundMethodSelf-citationBaneira, F., Doval-Gandoy, J., Yepes, A. G., Lopez, O., & Perez-Estevez, D. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2620426 · Cited by 173
“Among all multiphase machines, the six-phase one with AWA, commonly named dual three-phase machine, has been extensively studied in recent years [7], [31], [34], [35].”
BackgroundLuo, Y., & Liu, C. (2019) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2018.2883665 · Cited by 84
Bhuiyan, E. A., Akhand, M. M. A., Das, S. K., Ali, M. F., Tasneem, Z., Islam, M. R., Saha, D. K., Badal, F. R., Ahamed, M. H., & Moyeen, S. I. (2020) · International Journal of Automation and Computing · doi:10.1007/s11633-020-1250-3 · Cited by 68
Trabelsi, M., Semail, E., & Nguyen, N. K. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2719634 · Cited by 61
“In [23] and [24], for almost sinusoidal five-phase machines, it is shown clearly, as in [22], that the inverter fault induces a fault current component in the second plane instead”
Aciego, J. J., Duran, M. J., Gonzalez-Prieto, I., & Barrero, F. (2024) · RE&PQJ · doi:10.24084/repqj15.359 · Cited by 3
“Apart from the well-known fault tolerant capability [6-10], some other innovative uses of the additional degrees of freedom have appeared in recent times [11-13].”
BackgroundSelf-citation
Metadata
- Authors
- Guzman, H., Duran, M. J., Barrero, F., Zarri, L., Bogado, B., Gonzalez Prieto, I., & Arahal, M. R.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2016-01
- Volume
- 63
- Issue
- 1
- Pages
- 606-617
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2049732871
- Cited by
- 231
- References
- 19
- FWCI
- 14.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.