Fast and Robust Phase Estimation Algorithm for Heavily Distorted Grid Conditions
The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
This paper proposes a fast and robust phase estimation algorithm (PEA), a counterpart of the phase-locked loop (PLL), for heavily distorted grid conditions. The PEA, named as the WLSE-PEA, consists of the moving average filter (MAF), the weighted least squares estimation (WLSE), the frequency-locked loop (FLL), and the zero crossing detection (ZCD). The MAF can eliminate all the odd-order harmonics in the distorted grid voltages. The WLSE is employed to estimate the fundamental positive-sequence component. The combination of the ZCD and the FLL enables the WLSE-PEA to be adaptive to frequency deviations. Compared with some advanced phase-locked loops, the proposed WLSE-PEA has a faster response. Also, it is robust to common grid disturbances including three-phase unbalances, dc offsets, harmonics, phase jumps, and voltage sags. Simulation and experimental results have verified the effectiveness and advantages of the WLSE-PEA.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Overview of Control and Grid Synchronization for Distributed Power Generation Systems
Blaabjerg, F., Teodorescu, R., Liserre, M., & Timbus, A. V. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.881997 · Cited by 5,220
Decoupled Double Synchronous Reference Frame PLL for Power Converters Control
Rodriguez, P., Pou, J., Bergas, J., Candela, J. I., Burgos, R. P., & Boroyevich, D. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.890000 · Cited by 1,359
A phase tracking system for three phase utility interface inverters
Chung, S.-K. (2000) · IEEE Transactions on Power Electronics · doi:10.1109/63.844502 · Cited by 1,192
Operation of a phase locked loop system under distorted utility conditions
Kaura, V., & Blasko, V. (1997) · IEEE Transactions on Industry Applications · doi:10.1109/28.567077 · Cited by 997
Operation of a phase locked loop system under distorted utility conditions
Kaura, V., & Blasko, V. (2002) · Proceedings of Applied Power Electronics Conference. APEC '96 · doi:10.1109/apec.1996.500517 · Cited by 903
Rodríguez, P., Teodorescu, R., Candela, I., Timbus, A. V., Liserre, M., & Blaabjerg, F. (2006) · 2006 37th IEEE Power Electronics Specialists Conference · doi:10.1109/pesc.2006.1712059 · Cited by 842
Control for Grid-Connected and Intentional Islanding Operations of Distributed Power Generation
Balaguer, I. J., Lei, Q., Yang, S., Supatti, U., & Peng, F. Z. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2049709 · Cited by 622
Karimi-Ghartemani, M., & Iravani, M. R. (2004) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2004.831280 · Cited by 575
Moving Average Filter Based Phase-Locked Loops: Performance Analysis and Design Guidelines
Golestan, S., Ramezani, M., Guerrero, J. M., Freijedo, F. D., & Monfared, M. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2273461 · Cited by 564
Comparison of Three Single-Phase PLL Algorithms for UPS Applications
Santos Filho, R. M., Seixas, P. F., Cortizo, P. C., Torres, L. A. B., & Souza, A. F. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.924205 · Cited by 469
Addressing DC Component in PLL and Notch Filter Algorithms
Karimi-Ghartemani, M., Khajehoddin, S. A., Jain, P. K., Bakhshai, A., & Mojiri, M. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2158238 · Cited by 380
Control Strategies Based on Symmetrical Components for Grid-Connected Converters Under Voltage Dips
Alepuz, S., Busquets-Monge, S., Bordonau, J., Martinez-Velasco, J. A., Silva, C. A., Pontt, J., & Rodriguez, J. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2017102 · Cited by 373
Timbus, A., Liserre, M., Teodorescu, R., & Blaabjerg, F. (2006) · IEEE 36th Conference on Power Electronics Specialists, 2005. · doi:10.1109/pesc.2005.1581980 · Cited by 347
Active Synchronizing Control of a Microgrid
Cho, C., Jeon, J.-H., Kim, J.-Y., Kwon, S., Park, K., & Kim, S. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2162532 · Cited by 241
Problems of Startup and Phase Jumps in PLL Systems
Ghartemani, M. K., Khajehoddin, S. A., Jain, P. K., & Bakhshai, A. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2169089 · Cited by 233
LVRT Capability of DFIG-Based WECS Under Asymmetrical Grid Fault Condition
Geng, H., Liu, C., & Yang, G. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2226417 · Cited by 231
Self-citationA Fast and Accurate Synchronization Technique for Extraction of Symmetrical Components
Yazdani, D., Mojiri, M., Bakhshai, A., & Joos, G. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2010321 · Cited by 224
Tuning of Phase-Locked Loops for Power Converters Under Distorted Utility Conditions
Freijedo, F. D., Doval-Gandoy, J., Lopez, O., & Acha, E. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2031790 · Cited by 214
Grid Voltage Synchronization for Distributed Generation Systems Under Grid Fault Conditions
Luna, A., Rocabert, J., Candela, J. I., Hermoso, J. R., Teodorescu, R., Blaabjerg, F., & Rodriguez, P. (2015) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2015.2391436 · Cited by 201
Robust Controller for DFIGs of Grid-Connected Wind Turbines
da Costa, J. P., Pinheiro, H., Degner, T., & Arnold, G. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2098630 · Cited by 182
A Method to Improve the Dynamic Performance of Moving Average Filter-Based PLL
Wang, J., Liang, J., Gao, F., Zhang, L., & Wang, Z.-D. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2381673 · Cited by 152
An Efficient Implementation of Generalized Delayed Signal Cancellation PLL
Golestan, S., Freijedo, F. D., Vidal, A., Yepes, A. G., Guerrero, J. M., & Doval‐Gandoy, J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2420656 · Cited by 151
Golestan, S., Guerrero, J. M., & Gharehpetian, G. B. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2408113 · Cited by 151
Robles, E., Ceballos, S., Pou, J., Martín, J. L. M., Zaragoza, J., & Ibañez, P. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2050492 · Cited by 148
Instantaneous phase-angle estimation algorithm under unbalanced voltage-sag conditions
Song, H.-S., & Nam, K. (2000) · IEE Proceedings - Generation Transmission and Distribution · doi:10.1049/ip-gtd:20000716 · Cited by 139
MAF-PLL With Phase-Lead Compensator
Golestan, S., Guerrero, J. M., & Abusorrah, A. M. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2385658 · Cited by 126
A Novel Phase-Locked Loop Based on Frequency Detector and Initial Phase Angle Detector
Wang, L., Jiang, Q., Hong, L., Zhang, C., & Wei, Y. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2236848 · Cited by 115
Grid-synchronization methods for power converters
Freijedo, F. D., Doval‐Gandoy, J., López, Ó., Martínez-Peñalver, C., Yepes, A. G., Fernandez-Comesaña, P., Malvar, J., Nogueiras, A., Marcos, J., & Lago, A. (2009) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2009.5414976 · Cited by 69
Three-phase phase-lock loop for distorted utilities
Salamah, A. M., Finney, S. J., & Williams, B. W. (2007) · IET Electric Power Applications · doi:10.1049/iet-epa:20070036 · Cited by 65
Robles, E., Pou, J., Ceballos, S., Zaragoza, J., Martín, J. L. M., & Ibañez, P. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2098352 · Cited by 64
A Correlation-Based Islanding-Detection Method Using Current-Magnitude Disturbance for PV System
Yu, B., Matsui, M., & Yu, G.-J. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2080651 · Cited by 56
A Method to Improve PLL Performance Under Abnormal Grid Conditions
Ghoshal, A., & John, V. (2007) · NOT FOUND REPOSITORY (Indian Institute of Science Bangalore) · Cited by 55
Hybrid Synchronous/Stationary Reference-Frame-Filtering-Based PLL
Golestan, S., Guerrero, J. M., Abusorrah, A. M., & Al‐Turki, Y. A. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2393835 · Cited by 54
Beza, M., & Bongiorno, M. (2013) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2013.2279195 · Cited by 46
Dong, D., Wen, B., Mattavelli, P., Boroyevich, D., & Xue, Y. S. (2014) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2014.2345783 · Cited by 44
Rodríguez, P., Luna, Á., Teodorescu, R., & Blaabjerg, F. (2008) · doi:10.1109/energy.2008.4781065 · Cited by 16
Improved phase-locked loop under heavily distorted grid condition
Zheng, L., Geng, H., & Yang, G. (2015) · Proceedings of the Annual Conference of the IEEE Industrial Electronics Society · doi:10.1109/iecon.2015.7392847 · Cited by 5
Self-citationWLSE for fast, accurate and robust generation of references in power converter applications
Freijedo, F. D., Vidal, A., Yepes, A. G., Fernandez-Comesaña, P., Malvar, J., López, Ó., Nogueiras, A., & Doval‐Gandoy, J. (2010) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie.2010.5637405 · Cited by 4
Cited by
Zhang, C., Zhao, X., Wang, X., Chai, X., Zhang, Z., & Guo, X. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2810499 · Cited by 235
“Therefore, the implementation of accurate phase locking under nonideal grid voltage conditions has become a research hotspot in recent years [3]–[5].”
BackgroundGuo, X., Liu, W., & Lu, Z. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2669018 · Cited by 201
“Other PLL can also be utilized for grid synchronization [27]–[29].”
BackgroundXie, M., Wen, H., Zhu, C., & Yang, Y. (2017) · IEEE Access · doi:10.1109/access.2017.2719721 · Cited by 171
Kumar, N., Saxena, V., Singh, B., & Panigrahi, B. K. (2023) · IEEE Transactions on Consumer Electronics · doi:10.1109/tce.2023.3296480 · Cited by 110
“An adaptive technique based on the inference of neuro-fuzzy is proposed in [7].”
MethodGuo, X., Wei, B., Zhu, T., Lu, Z., Tan, L., Sun, X., & Zhang, C. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2692753 · Cited by 101
Metadata
- Authors
- Zheng, L., Geng, H., & Yang, G.
- Affiliations
- Georgia Institute of Technology (US)
- Tsinghua University (CN)
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2016-11
- Volume
- 63
- Issue
- 11
- Pages
- 6845-6855
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2465045278
- Cited by
- 83
- References
- 38
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 2 · 2023: 9 · 2022: 11 · 2021: 8 · 2020: 16 · 2019: 11 · 2018: 11 · 2017: 11
- FWCI
- 9.25
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Industrial Electronics (publishedVersion)
- Funders
- National Natural Science Foundation of China (U1510208, 61273045, 51361135705)
- National High Technology Research and Development Program of China (2012AA050217)
- National Key Research and Development Program (2016YFB0900302)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Electrical Measurement Techniques
- Keywords
- phase estimation, phase-locked loop, grid synchronization, voltage distortion, weighted least squares estimation, moving average filter, frequency-locked loop, zero-crossing detection, positive sequence component, three-phase unbalance, DC offset, harmonics, phase jumps, voltage sag, grid disturbances
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.