The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Characteristics and Restraining Method of Fast Transient Inrush Fault Currents in Synchronverters
Abstract
Large transient inrush fault current in a synchronverter during a short-circuit fault can potentially damage the inverter and cause grid instability. It is therefore important to study the characteristics of and the way to restrain the inrush fault current. This paper investigates the characteristics of the synchronverter inrush fault current and proposes a new control method based on mode switching to protect synchronverters. First, an ideal voltage source inverter instantaneous inrush current calculation method for a grid symmetrical short circuit is discussed. Then, based on the inertia of synchronverter, the approximate calculation of the synchronverter instantaneous inrush current is described. The results show that the synchronverter's inrush current mainly consists of a gradually attenuated periodic component and a dc component when the phased voltage symmetry is lost. In our proposed new control approach, the synchronverter switches to the hysteresis controller to limit the output current quickly while staying connected to the grid, and supporting the grid voltage simultaneously. Simulation and experiment results verify the validity of the theoretical analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Self-Synchronized Synchronverters: Inverters Without a Dedicated Synchronization Unit
Zhong, Q.-C., Nguyen, P.-L., Ma, Z., & Sheng, W. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2258684 · Cited by 1,026
Cited by
Grid-Forming Converters: Control Approaches, Grid-Synchronization, and Future Trends—A Review
Rosso, R., Wang, X., Liserre, M., Lu, X., & Engelken, S. (2021) · IEEE Open Journal of Industry Applications · doi:10.1109/ojia.2021.3074028 · Cited by 1,187
Transient Angle Stability of Virtual Synchronous Generators Using Lyapunov’s Direct Method
Shuai, Z., Shen, C., Liu, X., Li, Z., & Shen, Z. J. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2018.2866122 · Cited by 546
Self-citationFuture low-inertia power systems: Requirements, issues, and solutions - A review
Ratnam, K. S., Palanisamy, K., & Yang, G. (2020) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2020.109773 · Cited by 474
Current Limiting Control With Enhanced Dynamics of Grid-Forming Converters During Fault Conditions
Taul, M. G., Wang, X., Davari, P., & Blaabjerg, F. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2931477 · Cited by 466
Overcurrent Limiting in Grid-Forming Inverters: A Comprehensive Review and Discussion
Baeckeland, N., Chatterjee, D., Lu, M., Johnson, B., & Seo, G.-S. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3430316 · Cited by 271
Metadata
- Authors
- Shuai, Z., Huang, W., Shen, C., Ge, J., & Shen, Z. J.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2017-09
- Volume
- 64
- Issue
- 9
- Pages
- 7487-7497
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2579136728
- Cited by
- 246
- References
- 1
- FWCI
- 16.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Characteristics and Restraining Method of Fast Transient Inrush Fault Currents in Synchronverters. https://app.cochat.ai/papers/10.1109/tie.2017.2652362
- The paper
- Shuai, Z., Huang, W., Shen, C., Ge, J., & Shen, Z. J. (2017). Characteristics and Restraining Method of Fast Transient Inrush Fault Currents in Synchronverters. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2017.2652362
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.