The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Analysis and Stabilization of a Smart Transformer-Fed Grid
Open accessAbstract
The stability of the grid-connected inverters adopted in distributed energy resources (DERs) highly depends on the characteristics of the grid impedance. Hence, various active damping methods and adaptive control algorithms have been proposed for the control of the grid inverters. Differently from those existing solutions, this paper proposes to use a smart transformer (ST) to shape the grid impedance to interact with the controllers of local inverters, aiming at improving the stability of the local controllers as well as the overall grid. A main advantage of this solution is that it offers a pervasive service to all the available DERs, reducing the cost and design effort of the local controllers. Three active damping methods are presented in this paper and the implementation issues in the ST LV-side voltage controller are given. Moreover, the design criteria of the active damping methods considering the control performance of ST and the stability requirements of local DERs are presented. Analysis and experiments are carried out to verify the effectiveness of the proposed solution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Impedance-Based Stability Criterion for Grid-Connected Inverters
Sun, J. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2136439 · Cited by 2,574
Input-Admittance Calculation and Shaping for Controlled Voltage-Source Converters
Harnefors, L., Bongiorno, M., & Lundberg, S. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.904022 · Cited by 1,117
Liserre, M., Teodorescu, R., & Blaabjerg, F. (2006) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2005.861185 · Cited by 1,101
Self-citationModeling and Analysis of Harmonic Stability in an AC Power-Electronics-Based Power System
Wang, X., Blaabjerg, F., & Wu, W. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2306432 · Cited by 785
Filter-Based Active Damping of Voltage Source Converters With $LCL$ Filter
Dannehl, J., Liserre, M., & Fuchs, F. W. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2081952 · Cited by 648
Self-citationRegions of Active Damping Control for LCL Filters
Parker, S. G., McGrath, B. P., & Holmes, D. G. (2014) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2013.2266892 · Cited by 624
Agorreta, J. L., Borrega, M., López, J., & Marroyo, L. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2095429 · Cited by 596
A method of defining the load impedance specification for a stable distributed power system
Wildrick, C. M., Lee, F. C., Cho, B. H., & Choi, B. (1995) · IEEE Transactions on Power Electronics · doi:10.1109/63.387992 · Cited by 520
Wen, B., Boroyevich, D., Burgos, R., Mattavelli, P., & Shen, Z. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2378731 · Cited by 453
The Smart Transformer: Impact on the Electric Grid and Technology Challenges
Liserre, M., Buticchi, G., Andresen, M., De Carne, G., Costa, L. F., & Zou, Z.-X. (2016) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2016.2551418 · Cited by 445 · cited 1×
“voltage between MV and LV grids while providing ancillary services to both utility and customers [10], for instance, voltage and current profiles improvement, balancing services in MV and”
BackgroundSelf-citationFlexible AC Transmission Systems: Modelling and Control
Zhang, X.-P., Rehtanz, C., & Pal, B. (2012) · Power Systems · doi:10.1007/978-3-642-28241-6 · Cited by 438
Grid-Filter Design for a Multimegawatt Medium-Voltage Voltage-Source Inverter
Rockhill, A. A., Liserre, M., Teodorescu, R., & Rodriguez, P. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2087293 · Cited by 421
Self-citationDynamic Stability of a Microgrid With an Active Load
Bottrell, N., Prodanovic, M., & Green, T. C. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2241455 · Cited by 416
A method of defining the load impedance specification for a stable distributed power system
Wildrick, C. M., Lee, F. C., Cho, B. H., & Choi, B. (2002) · Proceedings of IEEE Power Electronics Specialist Conference - PESC '93 · doi:10.1109/pesc.1993.472017 · Cited by 401
Control and Resonance Damping of Voltage-Source and Current-Source Converters With $LC$ Filters
Li, Y. W. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2009562 · Cited by 372
An Active Damper for Stabilizing Power-Electronics-Based AC Systems
Wang, X., Blaabjerg, F., Liserre, M., Chen, Z., He, J., & Li, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2278716 · Cited by 367
Self-citationAdaptive Control of Grid-Connected Inverters Based on Online Grid Impedance Measurements
Cespedes, M., & Sun, J. (2014) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2013.2295201 · Cited by 327
Grid Impedance Estimation via Excitation of $LCL$-Filter Resonance
Liserre, M., Blaabjerg, F., & Teodorescu, R. (2007) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2007.904439 · Cited by 216
Self-citationPeña-Alzola, R., Liserre, M., Blaabjerg, F., Ordonez, M., & Kerekes, T. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2304468 · Cited by 194
Self-citationOptimal Damping of EMI Filter Input Impedance
Xing, L., Feng, F., & Sun, J. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2127434 · Cited by 81
An Ideal PWM-VSI Inverter with Feedforward and Feedback Compensation
Pedersen, J. K., Blaabjerg, F., Jensen, J. W., & Thøgersen, P. (1993) · VBN Forskningsportal (Aalborg Universitet) · Cited by 79
Passivity-Based Control by Series/Parallel Damping of Single-Phase PWM Voltage Source Converter
del Puerto-Flores, D., Scherpen, J. M. A., Liserre, M., de Vries, M. M. J., Kransse, M. J., & Monopoli, V. G. (2013) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2013.2278781 · Cited by 66
Self-citationRiccobono, A., & Santi, E. (2012) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2012.2229686 · Cited by 63
Passivity-Based Harmonic Control through Series/Parallel Damping of an H-Bridge Rectifier
de Vries, M. M. J., Kransse, M. J., Liserre, M., Monopoli, V. G., & Scherpen, J. M. A. (2007) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie.2007.4375160 · Cited by 13
Self-citation
Cited by
Grid-Forming Converters: Control Approaches, Grid-Synchronization, and Future Trends—A Review
Rosso, R., Wang, X., Liserre, M., Lu, X., & Engelken, S. (2021) · IEEE Open Journal of Industry Applications · doi:10.1109/ojia.2021.3074028 · Cited by 1,187
Self-citationHannan, M. A., Ker, P. J., Lipu, M. S. H., Choi, Z. H., Rahman, M. S. A., Muttaqi, K. M., & Blaabjerg, F. (2020) · IEEE Access · doi:10.1109/access.2020.2967345 · Cited by 339
“Many researches have been done on three-stage topology [70], [134], [131]; however, only a few for two-stage topology”
BackgroundRuiz, F., Pérez, M. A., Espinosa, J. R., Gajowik, T., Styński, S., & Malinowski, M. (2020) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2019.2950436 · Cited by 143
A review on solid-state transformer: A breakthrough technology for future smart distribution grids
Mishra, D. K., Ghadi, M. J., Li, L., Hossain, M. J., Zhang, J., Ray, P. K., & Mohanty, A. (2021) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2021.107255 · Cited by 128
Grid-forming converters: an overview of control approaches and future trends
Rosso, R., Wang, X., Liserre, M., Lu, X., & Engelken, S. (2020) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce44975.2020.9236211 · Cited by 123
Self-citation
Metadata
- Authors
- Zou, Z.-X., Buticchi, G., & Liserre, M.
- Affiliations
- University of Nottingham Ningbo China (CN)
- Christian-Albrechts-Universität zu Kiel (DE)
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2018-02
- Volume
- 65
- Issue
- 2
- Pages
- 1325-1335
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2740591315
- Cited by
- 41
- References
- 24
- Citations by year
- 2025: 3 · 2024: 2 · 2023: 5 · 2022: 7 · 2021: 5 · 2020: 9 · 2019: 4 · 2018: 6
- FWCI
- 3.26
- Type
- journal article
- Language
- en
- Open access
- green
- macau.uni-kiel.de
- Locations
- IEEE Transactions on Industrial Electronics (publishedVersion)
- MACAU: Open Access Repository of Kiel University (University Library Kiel) (submittedVersion)
- Multimedialen Archiv und Publikationsserver der Christian-Albrechts-Universität zu Kiel (Christian-Albrechts-Universität zu Kiel) (submittedVersion, other-oa)
- Funders
- HEART (European Research Council/616344)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Islanding Detection in Power Systems
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wind Turbine Control Systems
- Keywords
- solid-state transformer, grid-connected inverter, distributed energy resources, active damping, inverter stability, adaptive control, grid-connected power systems
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.