Analytical Modeling and Implementation of a Coaxially Wound Transformer With Integrated Filter Inductance for Isolated Soft-Switching DC–DC Converters
The DOI matches its Crossref record; 24 of the 26 references it cites were found in a registry or an index.
Abstract
In this paper, we propose an approach for integrating a series filter inductance in a coaxially wound transformer (CWT) as a potential alternative to conventional solenoidally wound transformers (SWT) for high-power isolated soft-switching dc-dc converters. The critical elements that determine the size and the performance of soft-switching dc-dc converters are the isolation transformer and the filter elements. While conventional SWTs using a stray magnetic field as a filter inductance often suffer from a considerably increased loss, heat congestion, and electromagnetic interference, a CWT is rarely affected by high frequency and fringing effects. The desired properties are still valid while the required filter inductance is fully integrated with an isolation transformer using the proposed method. In addition, the evenly distributed magnetic fields in a concentric geometry enable accurate electrical and mechanical analysis and a specific application-oriented design. In this paper, the operating principles, design procedure, and loss modeling of a CWT with an integrated filter inductance are introduced. Its functionality and suitability for high-frequency applications were proven by theoretical analysis and experiments. A prototype transformer with an integrated inductance 4 mH was facilitated and evaluated in a 15 kV-SiC mosfet-based 6 k-400 Vdc stage for a solid-state transformer of up to 6.5 kW at a switching frequency of 20 kHz.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Fundamentals of Power Electronics
Erickson, R. W., & Maksimović, D. (2001) · Springer eBooks · doi:10.1007/b100747 · Cited by 6,112
Fundamentals of Power Electronics
Erickson, R. W., & Maksimović, D. (2020) · Springer eBooks · doi:10.1007/978-3-030-43881-4 · Cited by 5,420
Performance characterization of a high-power dual active bridge DC-to-DC converter
Kheraluwala, M. N., Gascoigne, R. W., Divan, D. M., & Baumann, E. D. (1992) · IEEE Transactions on Industry Applications · doi:10.1109/28.175280 · Cited by 1,496
Effects of eddy currents in transformer windings
Dowell, P. L. (1966) · Proceedings of the Institution of Electrical Engineers · doi:10.1049/piee.1966.0236 · Cited by 1,438 · cited 1×
“4 [12].”
Review of Solid-State Transformer Technologies and Their Application in Power Distribution Systems
She, X., Huang, A. Q., & Burgos, R. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2277917 · Cited by 1,164
Improved analytical modeling of conductive losses in magnetic components
Ferreira, J. A. (1994) · IEEE Transactions on Power Electronics · doi:10.1109/63.285503 · Cited by 629 · cited 1×
“In addition, some reported results show that the impact of the airgap size is not simply linear or monotonic [15].”
BackgroundOptimal choice for number of strands in a litz-wire transformer winding
Sullivan, C. R. (1999) · IEEE Transactions on Power Electronics · doi:10.1109/63.750181 · Cited by 558
Improved Core-Loss Calculation for Magnetic Components Employed in Power Electronic Systems
Muhlethaler, J., Biela, J., Kolar, J. W., & Ecklebe, A. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2162252 · Cited by 535
Krismer, F., & Kolar, J. W. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2025284 · Cited by 470 · cited 2×
“5 with phase-shift modulation (PSM) [17].”
InfluentialLin, D., Zhou, P., Fu, W. N., Badics, Z., & Cendes, Z. J. (2004) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2004.825025 · Cited by 425
Research works printed but not linked: 1
- 2017, 20-3300 High Temperature and Thermal Shock Epoxy
Cited by
99% Efficient 10 kV SiC-Based 7 kV/400 V DC Transformer for Future Data Centers
Rothmund, D., Guillod, T., Bortis, D., & Kolar, J. W. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2886139 · Cited by 315
“This means that, in contrast to similar converters [21], [39], [40], the realized dc/dc converter not only achieves three times less (relative) full-load Fig.”
ResultAgarwal, R., Li, H., Guo, Z., & Cheetham, P. (2023) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3174243 · Cited by 79
“Researches in [1], [2] have designed MF frequency transformers for inductor tank based MV dc SST with PWM frequency from 3 kHz to 20 kHz.”
BackgroundSima, W., Peng, D., Yang, M., Sun, P., Zou, B., & Zhao, X. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.2977544 · Cited by 31
“(SSTs), which are crucial components involved in the active regulation of voltage and current in smart grids [4].”
BackgroundA High-Efficiency 80-kW Split Planar Transformer for Medium-Voltage Modular Power Conversion
Lu, S., Kong, D., Xu, S., Luo, L., & Li, S. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3151796 · Cited by 31
“The MFT with the coaxial structure can offer extremely low leakage inductance and its magnetic flux density distribution and thermal distribution are more uniform [13].”
BackgroundChen, Y., Fu, W. N., Lin, H., & Niu, S. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3202038 · Cited by 17
“K ILOHERTZ (kHz) transformer is a key device widely applied in switching power supply [1], [2] and isolated converters [3], [4], [5], [6].”
Background
Metadata
- Authors
- Baek, S., & Bhattacharya, S.
- Affiliations
- Kyungnam University (KR)
- ORCID
- Baek, Seunghun
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2018-03
- Volume
- 65
- Issue
- 3
- Pages
- 2245-2255
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2751753865
- Cited by
- 26
- References
- 26
- Citations by year
- 2025: 4 · 2024: 2 · 2023: 2 · 2022: 5 · 2021: 1 · 2020: 5 · 2019: 5 · 2018: 2
- FWCI
- 1.36
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Industrial Electronics (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electromagnetic Compatibility and Noise Suppression
- Keywords
- isolation transformer, solid-state transformer, SiC MOSFET, high-frequency power conversion, transformer design
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.